Skip to content
Projects
Groups
Snippets
Help
Loading...
Help
Support
Keyboard shortcuts
?
Submit feedback
Contribute to GitLab
Sign in / Register
Toggle navigation
P
proview
Project overview
Project overview
Details
Activity
Releases
Repository
Repository
Files
Commits
Branches
Tags
Contributors
Graph
Compare
Issues
0
Issues
0
List
Boards
Labels
Milestones
Merge Requests
0
Merge Requests
0
CI / CD
CI / CD
Pipelines
Jobs
Schedules
Analytics
Analytics
CI / CD
Repository
Value Stream
Wiki
Wiki
Snippets
Snippets
Members
Members
Collapse sidebar
Close sidebar
Activity
Graph
Create a new issue
Jobs
Commits
Issue Boards
Open sidebar
Esteban Blanc
proview
Commits
c71c2b13
Commit
c71c2b13
authored
Jan 23, 2006
by
claes
Browse files
Options
Browse Files
Download
Email Patches
Plain Diff
Alarm text changes, and motor default config
parent
5d193048
Changes
3
Hide whitespace changes
Inline
Side-by-side
Showing
3 changed files
with
139 additions
and
109 deletions
+139
-109
abb/wbl/mcomp/src/abb.wb_load
abb/wbl/mcomp/src/abb.wb_load
+102
-93
bcomp/wbl/bcomp/src/basecomponent.wb_load
bcomp/wbl/bcomp/src/basecomponent.wb_load
+27
-7
othermanu/wbl/mcomp/src/othermanufacturer.wb_load
othermanu/wbl/mcomp/src/othermanufacturer.wb_load
+10
-9
No files found.
abb/wbl/mcomp/src/abb.wb_load
View file @
c71c2b13
...
...
@@ -315,8 +315,8 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Parameter Identification (online parameter handling)
!*/
Object InIdPar $Attribute 55 01-DEC-2005 10:37:53.43
!*/
Object InIdPar $Attribute 55 01-DEC-2005 10:37:53.43
Body SysBody 01-DEC-2005 10:37:55.64
Attr PgmName = "InIdPar"
Attr Flags = 131072
...
...
@@ -325,7 +325,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Index for Array (online parameter handling)
!*/
!*/
Object InIndPar $Attribute 61 01-DEC-2005 11:08:20.68
Body SysBody 01-DEC-2005 11:08:22.06
Attr PgmName = "InIndPar"
...
...
@@ -335,7 +335,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Parameter Value (online parameter handling)
!*/
!*/
Object InValuePar $Attribute 56 01-DEC-2005 10:39:10.30
Body SysBody 01-DEC-2005 10:39:12.50
Attr PgmName = "InValuePar"
...
...
@@ -345,7 +345,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Actual Value Speed
!*/
!*/
Object ActSpeed $Attribute 3 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "ActSpeed"
...
...
@@ -355,7 +355,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Actual Value Tourque
!*/
!*/
Object ActTorque $Attribute 4 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "ActTorque"
...
...
@@ -365,7 +365,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Actual Value Current
!*/
!*/
Object ActCurrent $Attribute 5 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "ActCurrent"
...
...
@@ -375,7 +375,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Bit status, Ready, Warning, Error etc.
!*/
!*/
Object StatusWordSW $Attribute 8 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "StatusWordSW"
...
...
@@ -385,7 +385,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Bit status, Overcurrent, Earth fault etc.
!*/
!*/
Object FaultWord1 $Attribute 10 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "FaultWord1"
...
...
@@ -395,7 +395,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Bit status, DC under voltage, Encoder fault etc.
!*/
!*/
Object FaultWord2 $Attribute 11 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "FaultWord2"
...
...
@@ -405,7 +405,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Status IO card input channel 1 to 6.
!*/
!*/
Object Di6_1 $Attribute 12 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "Di6_1"
...
...
@@ -415,7 +415,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Bit status, Interlock input etc.
!*/
!*/
Object StatusWordSW3 $Attribute 41 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "StatusWordSW3"
...
...
@@ -425,7 +425,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Bit status, BR Overheat etc.
!*/
!*/
Object AlarmWord5 $Attribute 13 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "AlarmWord5"
...
...
@@ -435,7 +435,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Parameter Identification (online parameter handling)
!*/
!*/
Object OutIdPar $Attribute 52 01-DEC-2005 10:32:42.66
Body SysBody 01-DEC-2005 10:32:45.89
Attr PgmName = "OutIdPar"
...
...
@@ -445,7 +445,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Index for Array (online parameter handling)
!*/
!*/
Object OutIndPar $Attribute 53 01-DEC-2005 10:32:58.82
Body SysBody 01-DEC-2005 10:33:02.42
Attr PgmName = "OutIndPar"
...
...
@@ -455,7 +455,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Parameter Value (online parameter handling)
!*/
!*/
Object OutValuePar $Attribute 54 01-DEC-2005 10:33:09.62
Body SysBody 01-DEC-2005 10:33:11.85
Attr PgmName = "OutValuePar"
...
...
@@ -465,7 +465,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Control Word, start/stop, reset etc
!*/
!*/
Object ControlWordCW $Attribute 7 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "ControlWordCW"
...
...
@@ -475,7 +475,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Reference speed
!*/
!*/
Object RefSpeed $Attribute 9 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "RefSpeed"
...
...
@@ -485,7 +485,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Indicator in object graph showing converter warning
!*/
!*/
Object IndWarning $Attribute 14 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "IndWarning"
...
...
@@ -494,7 +494,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Indicator in object graph showing converter Fault
!*/
!*/
Object IndError $Attribute 15 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "IndError"
...
...
@@ -503,7 +503,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Button in object graph reset tripped converter
!*/
!*/
Object OpReset $Attribute 18 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:06:05.95
Attr PgmName = "OpReset"
...
...
@@ -513,7 +513,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Button in object graph "more..." write parameter
!*/
!*/
Object OpWritePar $Attribute 62 01-DEC-2005 11:14:25.99
Body SysBody 21-DEC-2005 09:06:12.64
Attr PgmName = "OpWritePar"
...
...
@@ -523,7 +523,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Button in object graph "more..." read parameter
!*/
!*/
Object OpReadPar $Attribute 63 01-DEC-2005 11:14:39.33
Body SysBody 21-DEC-2005 09:06:16.97
Attr PgmName = "OpReadPar"
...
...
@@ -533,7 +533,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Button in object graph "more..." backup parameters in converter
!*/
!*/
Object OpBackupPar $Attribute 65 06-DEC-2005 15:22:20.27
Body SysBody 21-DEC-2005 09:06:22.01
Attr PgmName = "OpBackupPar"
...
...
@@ -543,7 +543,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Communikation link to converter okey
!*/
!*/
Object CommOk $Attribute 16 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:06:37.84
Attr PgmName = "CommOk"
...
...
@@ -553,7 +553,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter has started up, alarm message "ready"
!*/
!*/
Object AlarmOk $Attribute 43 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:06:50.48
Attr PgmName = "AlarmOk"
...
...
@@ -563,7 +563,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter starting up "wait"
!*/
!*/
Object PowerStartUp $Attribute 21 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:06:59.52
Attr PgmName = "PowerStartUp"
...
...
@@ -573,7 +573,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Object ready for remote control
!*/
!*/
Object ReadyRemote $Attribute 22 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:07:03.76
Attr PgmName = "ReadyRemote"
...
...
@@ -583,7 +583,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter ready to start (status word)
!*/
!*/
Object ConvertReady $Attribute 23 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:07:08.70
Attr PgmName = "ConvertReady"
...
...
@@ -593,7 +593,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter/motor running (status word)
!*/
!*/
Object ConvertRun $Attribute 24 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:07:13.04
Attr PgmName = "ConvertRun"
...
...
@@ -603,7 +603,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter has tripped (status word)
!*/
!*/
Object ConvertTripped $Attribute 25 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:07:16.55
Attr PgmName = "ConvertTripped"
...
...
@@ -613,7 +613,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter/motor fault (status word)
!*/
!*/
Object ConvertFault $Attribute 28 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:07:20.73
Attr PgmName = "ConvertFault"
...
...
@@ -623,7 +623,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter warning (status word)
!*/
!*/
Object ConvertWarning $Attribute 26 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:07:24.82
Attr PgmName = "ConvertWarning"
...
...
@@ -633,7 +633,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter ready (status word) for remote control
!*/
!*/
Object ConvertRemote $Attribute 27 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:07:29.33
Attr PgmName = "ConvertRemote"
...
...
@@ -643,7 +643,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Time to "boot up" converter when energized
!*/
!*/
Object PowerUpTime $Attribute 19 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "PowerUpTime"
...
...
@@ -652,7 +652,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Value "requested parameter" in object graph "more..."
!*/
!*/
Object RequestPar $Attribute 58 01-DEC-2005 10:54:06.17
Body SysBody 21-DEC-2005 09:07:54.33
Attr PgmName = "RequestPar"
...
...
@@ -662,7 +662,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Value "write value parameter" in object graph "more..."
!*/
!*/
Object WriteValuePar $Attribute 57 01-DEC-2005 10:51:59.36
Body SysBody 21-DEC-2005 09:07:59.61
Attr PgmName = "WriteValuePar"
...
...
@@ -672,7 +672,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Value "read value parameter" in object graph "more..."
!*/
!*/
Object ReadValuePar $Attribute 59 01-DEC-2005 10:58:42.07
Body SysBody 21-DEC-2005 09:08:04.77
Attr PgmName = "ReadValuePar"
...
...
@@ -682,7 +682,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Value "return code value" in object graph "more..."
!*/
!*/
Object ReadCodePar $Attribute 60 01-DEC-2005 11:10:52.14
Body SysBody 21-DEC-2005 09:08:10.00
Attr PgmName = "ReadCodePar"
...
...
@@ -692,7 +692,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Value "return code subindex value" in object graph "more..."
!*/
!*/
Object ReadCodeSubPar $Attribute 64 01-DEC-2005 13:27:43.59
Body SysBody 21-DEC-2005 09:08:15.90
Attr PgmName = "ReadCodeSubPar"
...
...
@@ -702,7 +702,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Alarmmessage
!*/
!*/
Object AlarmLocalMod $Attribute 45 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "AlarmLocalMod"
...
...
@@ -711,7 +711,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Alarmmessage
!*/
!*/
Object AlarmTripped $Attribute 46 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "AlarmTripped"
...
...
@@ -720,7 +720,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Alarmmessage
!*/
!*/
Object AlarmFanOld $Attribute 47 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "AlarmFanOld"
...
...
@@ -729,7 +729,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Alarmmessage
!*/
!*/
Object AlarmWarning $Attribute 49 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "AlarmWarning"
...
...
@@ -738,7 +738,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Alarmmessage
!*/
!*/
Object AlarmError $Attribute 50 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "AlarmError"
...
...
@@ -843,7 +843,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
EndObject
Object Template ABB_ACS800_1 2148237312 12-OCT-2005 12:58:20.00
Body RtBody
06-DEC-2005 16:04:23.58
Body RtBody
23-JAN-2006 09:27:06.19
Attr Specification = "ABB ACS800 Frequency converter"
Attr InIdPar.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.I_ID"
Attr InIndPar.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.I_IND"
...
...
@@ -867,9 +867,9 @@ Volume ABB $ClassVolume 0.0.250.2
Attr RefSpeed.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.O_REF"
Attr RefSpeed.DefTrend = "ABB:Class-ABB_ACS800_1-Template.TrendRefSpeed"
Attr PowerUpTime = 1.500000e+01
Attr AlarmLocalMod = "Frequency converter
control location is local,
"
Attr AlarmTripped = "Frequency converter tripped,
you must reset
, "
Attr AlarmFanOld = "
Replace cooling fan in frequency converter
, "
Attr AlarmLocalMod = "Frequency converter
is in local mode,
"
Attr AlarmTripped = "Frequency converter tripped,
reset is required
, "
Attr AlarmFanOld = "
Maintenance replace of cooling fan in converter required
, "
Attr AlarmWarning = "Frequency converter warning, "
Attr AlarmError = "Frequency converter error, "
Attr DefTrend = "ABB:Class-ABB_ACS800_1-Template.PlotGroup"
...
...
@@ -936,7 +936,7 @@ Volume ABB $ClassVolume 0.0.250.2
!
! @b See also
! @classlink ABB_ACS800_1 abb_abb_acs800_1.html
!
!
!*/
Object ABB_ACS800_1Fo $ClassDef 3 07-DEC-2005 13:38:43.05
Body SysBody 01-JAN-1970 01:00:00.00
...
...
@@ -951,7 +951,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndBody
!/**
! Pin name "pwo", indicates energized converter. Used for alarm message.
!*/
!*/
Object PowerOn $Input 1 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:12:05.62
Attr PgmName = "PowerOn"
...
...
@@ -962,7 +962,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "sta", order start/run motor.
!*/
!*/
Object Start $Input 2 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "Start"
...
...
@@ -973,7 +973,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "REF", Speed referens motor.
!*/
!*/
Object RefSpeed $Input 5 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "RefSpeed"
...
...
@@ -990,7 +990,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "rdy", Ready for remote control.
!*/
!*/
Object ReadyRemote $Output 6 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:09:21.49
Attr PgmName = "ReadyRemote"
...
...
@@ -1001,7 +1001,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "run", motor started/running.
!*/
!*/
Object Run $Output 7 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:09:44.11
Attr PgmName = "Run"
...
...
@@ -1012,7 +1012,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "di1", status input signal DI1 on the converter.
!*/
!*/
Object Di1 $Output 9 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:09:55.84
Attr PgmName = "Di1"
...
...
@@ -1023,7 +1023,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "di2", status input signal DI2 on the converter.
!*/
!*/
Object Di2 $Output 10 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:10:00.34
Attr PgmName = "Di2"
...
...
@@ -1034,7 +1034,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "di3", status input signal DI3 on the converter.
!*/
!*/
Object Di3 $Output 11 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:10:04.69
Attr PgmName = "Di3"
...
...
@@ -1045,7 +1045,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "di4", status input signal DI4 on the converter.
!*/
!*/
Object Di4 $Output 12 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:10:08.94
Attr PgmName = "Di4"
...
...
@@ -1056,7 +1056,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "di5", status input signal DI5 on the converter.
!*/
!*/
Object Di5 $Output 13 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:10:13.16
Attr PgmName = "Di5"
...
...
@@ -1067,7 +1067,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "di6", status input signal DI6 on the converter.
!*/
!*/
Object Di6 $Output 14 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:10:16.98
Attr PgmName = "Di6"
...
...
@@ -1078,7 +1078,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "diil", status input signal DIIL (interlock) on the converter.
!*/
!*/
Object DiIL $Output 15 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:10:22.43
Attr PgmName = "DiIL"
...
...
@@ -11434,7 +11434,7 @@ ABB ACS800 Typ 1"
!
! @h1 Configuration
!
!
!
! @b Plc coding
! For plc coding the function object ABB_ACS800MotorAggrFo is used.
! @image orm_abb_acs800motoraggrfo_fo.gif
...
...
@@ -11929,10 +11929,10 @@ ABB ACS800 Typ 1"
EndObject
EndObject
Object Template ABB_ACS800MotorAggr 2148761600 12-OCT-2005 12:58:20.00
Body RtBody
06-DEC-2005 16:07:32.85
Attr AlarmTextToOften = "
Start up converter (power on) to often, wait before try again
"
Attr AlarmTextPowOnNotOk = "
Check interlocks! Start up (power on) converter is not allowed
"
Attr AlarmTextStartNoOk = "Power is not on,
start is not allowed
"
Body RtBody
23-JAN-2006 09:29:23.78
Attr AlarmTextToOften = "
Power not yet ready for restart, wait before retry,
"
Attr AlarmTextPowOnNotOk = "
Power interlocked,
"
Attr AlarmTextStartNoOk = "Power is not on, "
Attr CircuitBreaker.AlarmText = "Circuit breaker tripped, "
Attr Contactor.FbTimeLimit = 1.000000e+00
Attr Contactor.AlarmText = "Feedback contactor lost, "
...
...
@@ -11960,9 +11960,9 @@ ABB ACS800 Typ 1"
Attr ACS800.RefSpeed.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.O_REF"
Attr ACS800.RefSpeed.PresMaxLimit = 2.000000e+03
Attr ACS800.PowerUpTime = 1.500000e+01
Attr ACS800.AlarmLocalMod = "Frequency converter
control location is local,
"
Attr ACS800.AlarmTripped = "Frequency converter tripped,
you must reset
, "
Attr ACS800.AlarmFanOld = "
Replace cooling fan in frequency converter
, "
Attr ACS800.AlarmLocalMod = "Frequency converter
is in local mode,
"
Attr ACS800.AlarmTripped = "Frequency converter tripped,
reset is required
, "
Attr ACS800.AlarmFanOld = "
Maintenance replace of cooling fan in converter required
, "
Attr ACS800.AlarmWarning = "Frequency converter warning, "
Attr ACS800.AlarmError = "Frequency converter error, "
Attr ACS800.DefTrend = "ABB:Class-ABB_ACS800MotorAggr-Template.ACS800.PlotGroup"
...
...
@@ -12003,6 +12003,9 @@ ABB ACS800 Typ 1"
Attr ACS800.PlotGroup.YUnit[2] = "A"
Attr ACS800.PlotGroup.NumPoints = 478
Attr SafetySwitch.AlarmText = "Safety switch is off, "
Attr Motor.GraphConfiguration = 2
Attr Motor.DisableTempSwitch = 1
Attr Motor.TempSwitch.Super.DisableSwitch = 1
Attr Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Motor.DisableTempSensor = 1
Attr Motor.TempSensor.Super.DisableValue = 1
...
...
@@ -12045,7 +12048,7 @@ ABB ACS800 Typ 1"
!
! Connect the function object to an object of class or subclass of
! ABB_ACS800MotorAggr.
!
!
! @b Example
! @image orm_abb_acs800motoraggrfo_ex.gif
!
...
...
@@ -21871,10 +21874,10 @@ ABB ACS800 Aggregate
EndObject
EndObject
Object Template ABB_ACS800PumpAggr 2151120896 01-JAN-1970 01:00:00.00
Body RtBody
16-DEC-2005 16:21:15.77
Attr Super.AlarmTextToOften = "
Start up converter (power on) to often, wait before try again
"
Attr Super.AlarmTextPowOnNotOk = "
Check interlocks! Start up (power on) converter is not allowed
"
Attr Super.AlarmTextStartNoOk = "Power is not on,
start is not allowed
"
Body RtBody
23-JAN-2006 09:29:54.52
Attr Super.AlarmTextToOften = "
Power not yet ready for restart, wait before retry,
"
Attr Super.AlarmTextPowOnNotOk = "
Power interlocked,
"
Attr Super.AlarmTextStartNoOk = "Power is not on, "
Attr Super.CircuitBreaker.AlarmText = "Circuit breaker tripped, "
Attr Super.Contactor.FbTimeLimit = 1.000000e+00
Attr Super.Contactor.AlarmText = "Feedback contactor lost, "
...
...
@@ -21885,9 +21888,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.ActCurrent.PresMaxLimit = 5.000000e+01
Attr Super.ACS800.RefSpeed.PresMaxLimit = 2.000000e+03
Attr Super.ACS800.PowerUpTime = 1.500000e+01
Attr Super.ACS800.AlarmLocalMod = "Frequency converter
control location is local,
"
Attr Super.ACS800.AlarmTripped = "Frequency converter tripped,
you must reset
, "
Attr Super.ACS800.AlarmFanOld = "
Replace cooling fan in frequency converter
, "
Attr Super.ACS800.AlarmLocalMod = "Frequency converter
is in local mode,
"
Attr Super.ACS800.AlarmTripped = "Frequency converter tripped,
reset is required
, "
Attr Super.ACS800.AlarmFanOld = "
Maintenance replace of cooling fan in converter required
, "
Attr Super.ACS800.AlarmWarning = "Frequency converter warning, "
Attr Super.ACS800.AlarmError = "Frequency converter error, "
Attr Super.ACS800.DefTrend = "ABB:Class-ABB_ACS800PumpAggr-Template.Super.ACS800.PlotGroup"
...
...
@@ -21928,6 +21931,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.PlotGroup.YUnit[2] = "A"
Attr Super.ACS800.PlotGroup.NumPoints = 478
Attr Super.SafetySwitch.AlarmText = "Safety switch is off, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1
...
...
@@ -22046,10 +22052,10 @@ ABB ACS800 Aggregate
EndObject
EndObject
Object Template ABB_ACS800FanAggr 2151383040 01-JAN-1970 01:00:00.00
Body RtBody
16-DEC-2005 16:23:59.95
Attr Super.AlarmTextToOften = "
Start up converter (power on) to often, wait before try again
"
Attr Super.AlarmTextPowOnNotOk = "
Check interlocks! Start up (power on) converter is not allowed
"
Attr Super.AlarmTextStartNoOk = "Power is not on,
start is not allowed
"
Body RtBody
23-JAN-2006 09:30:28.13
Attr Super.AlarmTextToOften = "
Power not yet ready for restart, wait before retry,
"
Attr Super.AlarmTextPowOnNotOk = "
Power interlocked,
"
Attr Super.AlarmTextStartNoOk = "Power is not on, "
Attr Super.CircuitBreaker.AlarmText = "Circuit breaker tripped, "
Attr Super.Contactor.FbTimeLimit = 1.000000e+00
Attr Super.Contactor.AlarmText = "Feedback contactor lost, "
...
...
@@ -22077,9 +22083,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.RefSpeed.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.O_REF"
Attr Super.ACS800.RefSpeed.PresMaxLimit = 2.000000e+03
Attr Super.ACS800.PowerUpTime = 1.500000e+01
Attr Super.ACS800.AlarmLocalMod = "Frequency converter
control location is local,
"
Attr Super.ACS800.AlarmTripped = "Frequency converter tripped,
you must reset
, "
Attr Super.ACS800.AlarmFanOld = "
Replace cooling fan in frequency converter
, "
Attr Super.ACS800.AlarmLocalMod = "Frequency converter
is in local mode,
"
Attr Super.ACS800.AlarmTripped = "Frequency converter tripped,
reset is required
, "
Attr Super.ACS800.AlarmFanOld = "
Maintenance replace of cooling fan in converter required
, "
Attr Super.ACS800.AlarmWarning = "Frequency converter warning, "
Attr Super.ACS800.AlarmError = "Frequency converter error, "
Attr Super.ACS800.DefTrend = "ABB:Class-ABB_ACS800FanAggr-Template.Super.ACS800.PlotGroup"
...
...
@@ -22120,6 +22126,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.PlotGroup.YUnit[2] = "A"
Attr Super.ACS800.PlotGroup.NumPoints = 478
Attr Super.SafetySwitch.AlarmText = "Safety switch is off, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1
...
...
@@ -22161,7 +22170,7 @@ ABB ACS800 Aggregate
! The object is configured under a PbSlave object in the node hierarchy.
! Connect the function object to an object of class or subclass of
! ABB_ACS800_1 with the IoConnect method.
!
!
! Fr att anpassa denna PPO5 konfigurations uppbyggnad (I/O) i Proview
! krvs instllningar i omriktarens parameterinstllningar.
!
...
...
@@ -22188,7 +22197,7 @@ ABB ACS800 Aggregate
!
! 98.02 = FIELDBUS Serial communication
! 98.07 = ABB Drives Communication profile
!
!
! Se also
! 16.01 = ? Run enable parameter
! 20.01 = ? Limits min speed
...
...
@@ -22200,8 +22209,8 @@ ABB ACS800 Aggregate
! 105, dvs driftvrdet "01.05" som r rvrdet momentet i omriktaren. Denna
! signal r i sin tur knuten till signalnamnet "ActTorque" i objektet
! "ABB_ACS800_1".
!
! OBS
!
!
! OBS
! vriga instllningar i omriktaren som mste till fr en fungerande
! kommunikation beaktas inte hr.
!
...
...
@@ -22298,7 +22307,7 @@ ABB ACS800 Aggregate
EndObject
!/**
! Fault word 1 (PZD5 Parameter 51.10 = 305) connected to "FaultWord1".
!*/
!*/
Object I_PZD5 $Attribute 9 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "I_PZD5"
...
...
@@ -22308,7 +22317,7 @@ ABB ACS800 Aggregate
EndObject
!/**
! Fault word 2 (PZD6 Parameter 51.12 = 306) connected to "FaultWord2".
!*/
!*/
Object I_PZD6 $Attribute 14 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "I_PZD6"
...
...
@@ -22318,7 +22327,7 @@ ABB ACS800 Aggregate
EndObject
!/**
! DI6-1 Status Input card on converter (PZD7 Parameter 51.14 = 117) connected to "Di6_1".
!*/
!*/
Object I_PZD7 $Attribute 13 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "I_PZD7"
...
...
@@ -22328,7 +22337,7 @@ ABB ACS800 Aggregate
EndObject
!/**
! Alarm word 5 (PZD8 Parameter 51.16 = 318) connected to "AlarmWord5".
!*/
!*/
Object I_PZD8 $Attribute 12 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "I_PZD8"
...
...
bcomp/wbl/bcomp/src/basecomponent.wb_load
View file @
c71c2b13
...
...
@@ -57885,11 +57885,12 @@ Alarm HH, H, L, LL"
EndObject
EndObject
Object Template BaseActuatorA 2176286720 01-JAN-1970 01:00:00.00
Body RtBody
03-OCT-2005 14:10:42.58
Body RtBody
23-JAN-2006 09:31:54.36
Attr Order.Unit = "%"
Attr Order.PresMaxLimit = 1.000000e+02
Attr Position.PresMaxLimit = 1.000000e+02
Attr Mode.OpNoLocal = 1
Attr Mode.OpMaxRefMan = 1.000000e+02
Attr Mode.AlarmLocalMode = "Local mode is activated, "
Attr MaxPosDiff = 5.000000e+00
Attr DiffAlarmDelay = 1.000000e+01
...
...
@@ -66517,12 +66518,13 @@ Alarm HH, H, L, LL"
EndObject
EndObject
Object Template BaseCValve 2177073152 01-JAN-1970 01:00:00.00
Body RtBody
03-OCT-2005 14:10:21.13
Body RtBody
23-JAN-2006 09:34:07.12
Attr Actuator.GraphConfiguration = 4
Attr Actuator.Order.Unit = "%"
Attr Actuator.Order.PresMaxLimit = 1.000000e+02
Attr Actuator.Position.PresMaxLimit = 1.000000e+02
Attr Actuator.Mode.OpNoLocal = 1
Attr Actuator.Mode.OpMaxRefMan = 1.000000e+02
Attr Actuator.Mode.AlarmLocalMode = "Local mode is activated, "
Attr Actuator.MaxPosDiff = 5.000000e+00
Attr Actuator.DiffAlarmDelay = 1.000000e+01
...
...
@@ -77365,7 +77367,10 @@ Alarm HH, H, L, LL"
EndObject
EndObject
Object Template BaseMotor 2177859584 01-JAN-1970 01:00:00.00
Body RtBody 01-DEC-2005 08:56:14.11
Body RtBody 23-JAN-2006 09:32:17.05
Attr GraphConfiguration = 2
Attr DisableTempSwitch = 1
Attr TempSwitch.Super.DisableSwitch = 1
Attr TempSwitch.Super.AlarmText = "High motor temperature, "
Attr DisableTempSensor = 1
Attr TempSensor.Super.DisableValue = 1
...
...
@@ -89907,7 +89912,7 @@ Safety switch"
EndObject
EndObject
Object Template BaseMotorAggr 2182316032 01-JAN-1970 01:00:00.00
Body RtBody
01-DEC-2005 08:57:09
.70
Body RtBody
23-JAN-2006 09:32:37
.70
Attr Contactor.Order.Description = "Energize contactor"
Attr Contactor.Feedback.Description = "Contactor is energized"
Attr Contactor.FbTimeLimit = 1.000000e+00
...
...
@@ -89921,8 +89926,12 @@ Safety switch"
Attr Mode.Alarm1LocalMod = "Local mode is activated, remote control is not allowed, "
Attr Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Mode.AlarmNotManOrd = "Automode active. Manual start/stop order is not allowed, "
Attr Motor.GraphConfiguration = 2
Attr Motor.DisableTempSwitch = 1
Attr Motor.TempSwitch.Super.DisableSwitch = 1
Attr Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Motor.DisableTempSensor = 1
Attr Motor.TempSensor.Super.DisableValue = 1
Attr Motor.TempSensor.Super.Value.Unit = "C"
Attr Motor.TempSensor.Super.Value.PresMaxLimit = 1.500000e+02
Attr Motor.TempSensor.Super.LimitHH.AlarmText = "High High motor temperature, "
...
...
@@ -95266,7 +95275,7 @@ Motor aggregat"
EndObject
EndObject
Object Template BaseFanAggr 2183364608 01-JAN-1970 01:00:00.00
Body RtBody
16-DEC-2005 15:58:47.74
Body RtBody
23-JAN-2006 09:32:57.88
Attr Super.Contactor.Order.Description = "Energize contactor"
Attr Super.Contactor.Feedback.Description = "Contactor is energized"
Attr Super.Contactor.FbTimeLimit = 1.000000e+00
...
...
@@ -95280,8 +95289,12 @@ Motor aggregat"
Attr Super.Mode.Alarm1LocalMod = "Local mode is activated, remote control is not allowed, "
Attr Super.Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Super.Mode.AlarmNotManOrd = "Automode active. Manual start/stop order is not allowed, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1
Attr Super.Motor.TempSensor.Super.Value.Unit = "C"
Attr Super.Motor.TempSensor.Super.Value.PresMaxLimit = 1.500000e+02
Attr Super.Motor.TempSensor.Super.LimitHH.AlarmText = "High High motor temperature, "
...
...
@@ -95380,7 +95393,7 @@ Motor aggregat"
EndObject
EndObject
Object Template BasePumpAggr 2184675328 01-JAN-1970 01:00:00.00
Body RtBody
16-DEC-2005 15:58:11.81
Body RtBody
23-JAN-2006 09:33:14.26
Attr Super.Contactor.Order.Description = "Energize contactor"
Attr Super.Contactor.Feedback.Description = "Contactor is energized"
Attr Super.Contactor.FbTimeLimit = 1.000000e+00
...
...
@@ -95394,8 +95407,12 @@ Motor aggregat"
Attr Super.Mode.Alarm1LocalMod = "Local mode is activated, remote control is not allowed, "
Attr Super.Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Super.Mode.AlarmNotManOrd = "Automode active. Manual start/stop order is not allowed, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1
Attr Super.Motor.TempSensor.Super.Value.Unit = "C"
Attr Super.Motor.TempSensor.Super.Value.PresMaxLimit = 1.500000e+02
Attr Super.Motor.TempSensor.Super.LimitHH.AlarmText = "High High motor temperature, "
...
...
@@ -96168,7 +96185,7 @@ Motor aggregat"
EndObject
EndObject
Object Template BaseMotorIncrDecrAggr 2185199616 01-JAN-1970 01:00:00.00
Body RtBody
16-DEC-2005 15:56:50.10
Body RtBody
23-JAN-2006 09:33:39.14
Attr ContactorIncr.Order.Description = "Energize contactor"
Attr ContactorIncr.Feedback.Description = "Contactor is energized"
Attr ContactorIncr.FbTimeLimit = 1.000000e+00
...
...
@@ -96188,6 +96205,9 @@ Motor aggregat"
Attr Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Mode.AlarmNotManOrd = "Automode active. Manual order is not allowed, "
Attr Mode.AlarmOrderTimeOut = "Timeout, limit switch not reached, "
Attr Motor.GraphConfiguration = 2
Attr Motor.DisableTempSwitch = 1
Attr Motor.TempSwitch.Super.DisableSwitch = 1
Attr Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Motor.DisableTempSensor = 1
Attr Motor.TempSensor.Super.DisableValue = 1
othermanu/wbl/mcomp/src/othermanufacturer.wb_load
View file @
c71c2b13
...
...
@@ -38,12 +38,12 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
EndObject
EndObject
Object Template Ventim_Valve_VM3001 2147975168 06-OCT-2005 09:28:20.00
Body RtBody
01-JAN-1970 01:00:00.00
Body RtBody
23-JAN-2006 09:22:29.15
Attr Super.Super.Specification = "Ventim Butterfly valve VM3001"
Attr Super.Super.DataSheet = "$pwr_lang/dsh/ventim_valve_vm3001.pdf"
Attr Super.SwitchOpen.Description = "Valve is open"
Attr Super.SwitchClosed.Description = "Valve is closed"
Attr Super.AlarmText = "Valve error"
Attr Super.AlarmText = "Valve error
,
"
EndBody
EndObject
EndObject
...
...
@@ -118,7 +118,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
EndObject
EndObject
Object Template Bernard_Actuator_OA 2150858752 06-OCT-2005 09:28:20.00
Body RtBody
06-OCT-2005 09:45:37.69
Body RtBody
23-JAN-2006 09:25:04.66
Attr Super.Super.Specification = "Bernard stlldon typ OA"
Attr Super.Super.DataSheet = "$pwr_lang/dsh/bernard_actuator_oa.html"
Attr Super.GraphConfiguration = 4
...
...
@@ -127,6 +127,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Position.Unit = "%"
Attr Super.Position.PresMaxLimit = 1.000000e+02
Attr Super.Mode.OpNoLocal = 1
Attr Super.Mode.OpMaxRefMan = 1.000000e+02
Attr Super.Mode.AlarmLocalMode = "Local mode is activated, "
Attr Super.MaxPosDiff = 5.000000e+00
Attr Super.DiffAlarmDelay = 1.000000e+01
...
...
@@ -249,9 +250,9 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Super.LimitHH.Limit = 9.500000e+01
Attr Super.Super.LimitH.AlarmText = "High limit exceeded, levelsensor "
Attr Super.Super.LimitH.Limit = 9.000000e+01
Attr Super.Super.LimitL.AlarmText = "Be
yond
Low limit, levelsensor "
Attr Super.Super.LimitL.AlarmText = "Be
low
Low limit, levelsensor "
Attr Super.Super.LimitL.Limit = 1.000000e+01
Attr Super.Super.LimitLL.AlarmText = "Be
yond
LowLow limit, levelsensor "
Attr Super.Super.LimitLL.AlarmText = "Be
low
LowLow limit, levelsensor "
Attr Super.Super.LimitLL.Limit = 5.000000e+00
Attr Super.Super.Trend.Multiple = 1
Attr Super.Super.Trend.DataName = "OtherManufacturer:Class-Impac_TempSensor_IN300-Template.Super.Super.Value.ActualValue"
...
...
@@ -377,9 +378,9 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Super.LimitHH.Limit = 9.500000e+01
Attr Super.Super.LimitH.AlarmText = "High limit exceeded, levelsensor "
Attr Super.Super.LimitH.Limit = 9.000000e+01
Attr Super.Super.LimitL.AlarmText = "Be
yond
Low limit, levelsensor "
Attr Super.Super.LimitL.AlarmText = "Be
low
Low limit, levelsensor "
Attr Super.Super.LimitL.Limit = 1.000000e+01
Attr Super.Super.LimitLL.AlarmText = "Be
yond
LowLow limit, levelsensor "
Attr Super.Super.LimitLL.AlarmText = "Be
low
LowLow limit, levelsensor "
Attr Super.Super.LimitLL.Limit = 5.000000e+00
Attr Super.Super.Trend.Multiple = 1
Attr Super.Super.Trend.DataName = "OtherManufacturer:Class-Mobrey_LevelSensor_MSP422-Template.Super.Super.Value.ActualValue"
...
...
@@ -467,9 +468,9 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Super.LimitHH.Limit = 9.500000e+01
Attr Super.Super.LimitH.AlarmText = "High limit exceeded, pressuresensor "
Attr Super.Super.LimitH.Limit = 9.000000e+01
Attr Super.Super.LimitL.AlarmText = "Be
yond
Low limit, pressuresensor "
Attr Super.Super.LimitL.AlarmText = "Be
low
Low limit, pressuresensor "
Attr Super.Super.LimitL.Limit = 1.000000e+01
Attr Super.Super.LimitLL.AlarmText = "Be
yond
LowLow limit, pressuresensor "
Attr Super.Super.LimitLL.AlarmText = "Be
low
LowLow limit, pressuresensor "
Attr Super.Super.LimitLL.Limit = 5.000000e+00
Attr Super.Super.Trend.Multiple = 1
Attr Super.Super.Trend.DataName = "OtherManufacturer:Class-Klay_PressureSensor_Series2000-Template.Super.Super.Value.ActualValue"
...
...