Commit c71c2b13 authored by claes's avatar claes

Alarm text changes, and motor default config

parent 5d193048
......@@ -315,8 +315,8 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Parameter Identification (online parameter handling)
!*/
Object InIdPar $Attribute 55 01-DEC-2005 10:37:53.43
!*/
Object InIdPar $Attribute 55 01-DEC-2005 10:37:53.43
Body SysBody 01-DEC-2005 10:37:55.64
Attr PgmName = "InIdPar"
Attr Flags = 131072
......@@ -325,7 +325,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Index for Array (online parameter handling)
!*/
!*/
Object InIndPar $Attribute 61 01-DEC-2005 11:08:20.68
Body SysBody 01-DEC-2005 11:08:22.06
Attr PgmName = "InIndPar"
......@@ -335,7 +335,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Parameter Value (online parameter handling)
!*/
!*/
Object InValuePar $Attribute 56 01-DEC-2005 10:39:10.30
Body SysBody 01-DEC-2005 10:39:12.50
Attr PgmName = "InValuePar"
......@@ -345,7 +345,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Actual Value Speed
!*/
!*/
Object ActSpeed $Attribute 3 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "ActSpeed"
......@@ -355,7 +355,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Actual Value Tourque
!*/
!*/
Object ActTorque $Attribute 4 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "ActTorque"
......@@ -365,7 +365,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Actual Value Current
!*/
!*/
Object ActCurrent $Attribute 5 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "ActCurrent"
......@@ -375,7 +375,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Bit status, Ready, Warning, Error etc.
!*/
!*/
Object StatusWordSW $Attribute 8 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "StatusWordSW"
......@@ -385,7 +385,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Bit status, Overcurrent, Earth fault etc.
!*/
!*/
Object FaultWord1 $Attribute 10 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "FaultWord1"
......@@ -395,7 +395,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Bit status, DC under voltage, Encoder fault etc.
!*/
!*/
Object FaultWord2 $Attribute 11 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "FaultWord2"
......@@ -405,7 +405,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Status IO card input channel 1 to 6.
!*/
!*/
Object Di6_1 $Attribute 12 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "Di6_1"
......@@ -415,7 +415,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Bit status, Interlock input etc.
!*/
!*/
Object StatusWordSW3 $Attribute 41 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "StatusWordSW3"
......@@ -425,7 +425,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Bit status, BR Overheat etc.
!*/
!*/
Object AlarmWord5 $Attribute 13 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "AlarmWord5"
......@@ -435,7 +435,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Parameter Identification (online parameter handling)
!*/
!*/
Object OutIdPar $Attribute 52 01-DEC-2005 10:32:42.66
Body SysBody 01-DEC-2005 10:32:45.89
Attr PgmName = "OutIdPar"
......@@ -445,7 +445,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Index for Array (online parameter handling)
!*/
!*/
Object OutIndPar $Attribute 53 01-DEC-2005 10:32:58.82
Body SysBody 01-DEC-2005 10:33:02.42
Attr PgmName = "OutIndPar"
......@@ -455,7 +455,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Parameter Value (online parameter handling)
!*/
!*/
Object OutValuePar $Attribute 54 01-DEC-2005 10:33:09.62
Body SysBody 01-DEC-2005 10:33:11.85
Attr PgmName = "OutValuePar"
......@@ -465,7 +465,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Control Word, start/stop, reset etc
!*/
!*/
Object ControlWordCW $Attribute 7 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "ControlWordCW"
......@@ -475,7 +475,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Reference speed
!*/
!*/
Object RefSpeed $Attribute 9 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "RefSpeed"
......@@ -485,7 +485,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Indicator in object graph showing converter warning
!*/
!*/
Object IndWarning $Attribute 14 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "IndWarning"
......@@ -494,7 +494,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Indicator in object graph showing converter Fault
!*/
!*/
Object IndError $Attribute 15 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "IndError"
......@@ -503,7 +503,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Button in object graph reset tripped converter
!*/
!*/
Object OpReset $Attribute 18 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:06:05.95
Attr PgmName = "OpReset"
......@@ -513,7 +513,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Button in object graph "more..." write parameter
!*/
!*/
Object OpWritePar $Attribute 62 01-DEC-2005 11:14:25.99
Body SysBody 21-DEC-2005 09:06:12.64
Attr PgmName = "OpWritePar"
......@@ -523,7 +523,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Button in object graph "more..." read parameter
!*/
!*/
Object OpReadPar $Attribute 63 01-DEC-2005 11:14:39.33
Body SysBody 21-DEC-2005 09:06:16.97
Attr PgmName = "OpReadPar"
......@@ -533,7 +533,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Button in object graph "more..." backup parameters in converter
!*/
!*/
Object OpBackupPar $Attribute 65 06-DEC-2005 15:22:20.27
Body SysBody 21-DEC-2005 09:06:22.01
Attr PgmName = "OpBackupPar"
......@@ -543,7 +543,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Communikation link to converter okey
!*/
!*/
Object CommOk $Attribute 16 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:06:37.84
Attr PgmName = "CommOk"
......@@ -553,7 +553,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter has started up, alarm message "ready"
!*/
!*/
Object AlarmOk $Attribute 43 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:06:50.48
Attr PgmName = "AlarmOk"
......@@ -563,7 +563,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter starting up "wait"
!*/
!*/
Object PowerStartUp $Attribute 21 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:06:59.52
Attr PgmName = "PowerStartUp"
......@@ -573,7 +573,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Object ready for remote control
!*/
!*/
Object ReadyRemote $Attribute 22 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:07:03.76
Attr PgmName = "ReadyRemote"
......@@ -583,7 +583,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter ready to start (status word)
!*/
!*/
Object ConvertReady $Attribute 23 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:07:08.70
Attr PgmName = "ConvertReady"
......@@ -593,7 +593,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter/motor running (status word)
!*/
!*/
Object ConvertRun $Attribute 24 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:07:13.04
Attr PgmName = "ConvertRun"
......@@ -603,7 +603,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter has tripped (status word)
!*/
!*/
Object ConvertTripped $Attribute 25 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:07:16.55
Attr PgmName = "ConvertTripped"
......@@ -613,7 +613,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter/motor fault (status word)
!*/
!*/
Object ConvertFault $Attribute 28 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:07:20.73
Attr PgmName = "ConvertFault"
......@@ -623,7 +623,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter warning (status word)
!*/
!*/
Object ConvertWarning $Attribute 26 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:07:24.82
Attr PgmName = "ConvertWarning"
......@@ -633,7 +633,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Converter ready (status word) for remote control
!*/
!*/
Object ConvertRemote $Attribute 27 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:07:29.33
Attr PgmName = "ConvertRemote"
......@@ -643,7 +643,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Time to "boot up" converter when energized
!*/
!*/
Object PowerUpTime $Attribute 19 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "PowerUpTime"
......@@ -652,7 +652,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Value "requested parameter" in object graph "more..."
!*/
!*/
Object RequestPar $Attribute 58 01-DEC-2005 10:54:06.17
Body SysBody 21-DEC-2005 09:07:54.33
Attr PgmName = "RequestPar"
......@@ -662,7 +662,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Value "write value parameter" in object graph "more..."
!*/
!*/
Object WriteValuePar $Attribute 57 01-DEC-2005 10:51:59.36
Body SysBody 21-DEC-2005 09:07:59.61
Attr PgmName = "WriteValuePar"
......@@ -672,7 +672,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Value "read value parameter" in object graph "more..."
!*/
!*/
Object ReadValuePar $Attribute 59 01-DEC-2005 10:58:42.07
Body SysBody 21-DEC-2005 09:08:04.77
Attr PgmName = "ReadValuePar"
......@@ -682,7 +682,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Value "return code value" in object graph "more..."
!*/
!*/
Object ReadCodePar $Attribute 60 01-DEC-2005 11:10:52.14
Body SysBody 21-DEC-2005 09:08:10.00
Attr PgmName = "ReadCodePar"
......@@ -692,7 +692,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Value "return code subindex value" in object graph "more..."
!*/
!*/
Object ReadCodeSubPar $Attribute 64 01-DEC-2005 13:27:43.59
Body SysBody 21-DEC-2005 09:08:15.90
Attr PgmName = "ReadCodeSubPar"
......@@ -702,7 +702,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Alarmmessage
!*/
!*/
Object AlarmLocalMod $Attribute 45 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "AlarmLocalMod"
......@@ -711,7 +711,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Alarmmessage
!*/
!*/
Object AlarmTripped $Attribute 46 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "AlarmTripped"
......@@ -720,7 +720,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Alarmmessage
!*/
!*/
Object AlarmFanOld $Attribute 47 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "AlarmFanOld"
......@@ -729,7 +729,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Alarmmessage
!*/
!*/
Object AlarmWarning $Attribute 49 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "AlarmWarning"
......@@ -738,7 +738,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Alarmmessage
!*/
!*/
Object AlarmError $Attribute 50 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "AlarmError"
......@@ -843,7 +843,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
EndObject
Object Template ABB_ACS800_1 2148237312 12-OCT-2005 12:58:20.00
Body RtBody 06-DEC-2005 16:04:23.58
Body RtBody 23-JAN-2006 09:27:06.19
Attr Specification = "ABB ACS800 Frequency converter"
Attr InIdPar.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.I_ID"
Attr InIndPar.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.I_IND"
......@@ -867,9 +867,9 @@ Volume ABB $ClassVolume 0.0.250.2
Attr RefSpeed.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.O_REF"
Attr RefSpeed.DefTrend = "ABB:Class-ABB_ACS800_1-Template.TrendRefSpeed"
Attr PowerUpTime = 1.500000e+01
Attr AlarmLocalMod = "Frequency converter control location is local, "
Attr AlarmTripped = "Frequency converter tripped, you must reset, "
Attr AlarmFanOld = "Replace cooling fan in frequency converter, "
Attr AlarmLocalMod = "Frequency converter is in local mode, "
Attr AlarmTripped = "Frequency converter tripped, reset is required, "
Attr AlarmFanOld = "Maintenance replace of cooling fan in converter required, "
Attr AlarmWarning = "Frequency converter warning, "
Attr AlarmError = "Frequency converter error, "
Attr DefTrend = "ABB:Class-ABB_ACS800_1-Template.PlotGroup"
......@@ -936,7 +936,7 @@ Volume ABB $ClassVolume 0.0.250.2
!
! @b See also
! @classlink ABB_ACS800_1 abb_abb_acs800_1.html
!
!
!*/
Object ABB_ACS800_1Fo $ClassDef 3 07-DEC-2005 13:38:43.05
Body SysBody 01-JAN-1970 01:00:00.00
......@@ -951,7 +951,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndBody
!/**
! Pin name "pwo", indicates energized converter. Used for alarm message.
!*/
!*/
Object PowerOn $Input 1 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:12:05.62
Attr PgmName = "PowerOn"
......@@ -962,7 +962,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "sta", order start/run motor.
!*/
!*/
Object Start $Input 2 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "Start"
......@@ -973,7 +973,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "REF", Speed referens motor.
!*/
!*/
Object RefSpeed $Input 5 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "RefSpeed"
......@@ -990,7 +990,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "rdy", Ready for remote control.
!*/
!*/
Object ReadyRemote $Output 6 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:09:21.49
Attr PgmName = "ReadyRemote"
......@@ -1001,7 +1001,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "run", motor started/running.
!*/
!*/
Object Run $Output 7 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:09:44.11
Attr PgmName = "Run"
......@@ -1012,7 +1012,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "di1", status input signal DI1 on the converter.
!*/
!*/
Object Di1 $Output 9 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:09:55.84
Attr PgmName = "Di1"
......@@ -1023,7 +1023,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "di2", status input signal DI2 on the converter.
!*/
!*/
Object Di2 $Output 10 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:10:00.34
Attr PgmName = "Di2"
......@@ -1034,7 +1034,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "di3", status input signal DI3 on the converter.
!*/
!*/
Object Di3 $Output 11 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:10:04.69
Attr PgmName = "Di3"
......@@ -1045,7 +1045,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "di4", status input signal DI4 on the converter.
!*/
!*/
Object Di4 $Output 12 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:10:08.94
Attr PgmName = "Di4"
......@@ -1056,7 +1056,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "di5", status input signal DI5 on the converter.
!*/
!*/
Object Di5 $Output 13 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:10:13.16
Attr PgmName = "Di5"
......@@ -1067,7 +1067,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "di6", status input signal DI6 on the converter.
!*/
!*/
Object Di6 $Output 14 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:10:16.98
Attr PgmName = "Di6"
......@@ -1078,7 +1078,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
!/**
! Pin name "diil", status input signal DIIL (interlock) on the converter.
!*/
!*/
Object DiIL $Output 15 12-OCT-2005 12:58:20.00
Body SysBody 21-DEC-2005 09:10:22.43
Attr PgmName = "DiIL"
......@@ -11434,7 +11434,7 @@ ABB ACS800 Typ 1"
!
! @h1 Configuration
!
!
!
! @b Plc coding
! For plc coding the function object ABB_ACS800MotorAggrFo is used.
! @image orm_abb_acs800motoraggrfo_fo.gif
......@@ -11929,10 +11929,10 @@ ABB ACS800 Typ 1"
EndObject
EndObject
Object Template ABB_ACS800MotorAggr 2148761600 12-OCT-2005 12:58:20.00
Body RtBody 06-DEC-2005 16:07:32.85
Attr AlarmTextToOften = "Start up converter (power on) to often, wait before try again "
Attr AlarmTextPowOnNotOk = "Check interlocks! Start up (power on) converter is not allowed "
Attr AlarmTextStartNoOk = "Power is not on, start is not allowed "
Body RtBody 23-JAN-2006 09:29:23.78
Attr AlarmTextToOften = "Power not yet ready for restart, wait before retry, "
Attr AlarmTextPowOnNotOk = "Power interlocked, "
Attr AlarmTextStartNoOk = "Power is not on, "
Attr CircuitBreaker.AlarmText = "Circuit breaker tripped, "
Attr Contactor.FbTimeLimit = 1.000000e+00
Attr Contactor.AlarmText = "Feedback contactor lost, "
......@@ -11960,9 +11960,9 @@ ABB ACS800 Typ 1"
Attr ACS800.RefSpeed.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.O_REF"
Attr ACS800.RefSpeed.PresMaxLimit = 2.000000e+03
Attr ACS800.PowerUpTime = 1.500000e+01
Attr ACS800.AlarmLocalMod = "Frequency converter control location is local, "
Attr ACS800.AlarmTripped = "Frequency converter tripped, you must reset, "
Attr ACS800.AlarmFanOld = "Replace cooling fan in frequency converter, "
Attr ACS800.AlarmLocalMod = "Frequency converter is in local mode, "
Attr ACS800.AlarmTripped = "Frequency converter tripped, reset is required, "
Attr ACS800.AlarmFanOld = "Maintenance replace of cooling fan in converter required, "
Attr ACS800.AlarmWarning = "Frequency converter warning, "
Attr ACS800.AlarmError = "Frequency converter error, "
Attr ACS800.DefTrend = "ABB:Class-ABB_ACS800MotorAggr-Template.ACS800.PlotGroup"
......@@ -12003,6 +12003,9 @@ ABB ACS800 Typ 1"
Attr ACS800.PlotGroup.YUnit[2] = "A"
Attr ACS800.PlotGroup.NumPoints = 478
Attr SafetySwitch.AlarmText = "Safety switch is off, "
Attr Motor.GraphConfiguration = 2
Attr Motor.DisableTempSwitch = 1
Attr Motor.TempSwitch.Super.DisableSwitch = 1
Attr Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Motor.DisableTempSensor = 1
Attr Motor.TempSensor.Super.DisableValue = 1
......@@ -12045,7 +12048,7 @@ ABB ACS800 Typ 1"
!
! Connect the function object to an object of class or subclass of
! ABB_ACS800MotorAggr.
!
!
! @b Example
! @image orm_abb_acs800motoraggrfo_ex.gif
!
......@@ -21871,10 +21874,10 @@ ABB ACS800 Aggregate
EndObject
EndObject
Object Template ABB_ACS800PumpAggr 2151120896 01-JAN-1970 01:00:00.00
Body RtBody 16-DEC-2005 16:21:15.77
Attr Super.AlarmTextToOften = "Start up converter (power on) to often, wait before try again "
Attr Super.AlarmTextPowOnNotOk = "Check interlocks! Start up (power on) converter is not allowed "
Attr Super.AlarmTextStartNoOk = "Power is not on, start is not allowed "
Body RtBody 23-JAN-2006 09:29:54.52
Attr Super.AlarmTextToOften = "Power not yet ready for restart, wait before retry, "
Attr Super.AlarmTextPowOnNotOk = "Power interlocked, "
Attr Super.AlarmTextStartNoOk = "Power is not on, "
Attr Super.CircuitBreaker.AlarmText = "Circuit breaker tripped, "
Attr Super.Contactor.FbTimeLimit = 1.000000e+00
Attr Super.Contactor.AlarmText = "Feedback contactor lost, "
......@@ -21885,9 +21888,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.ActCurrent.PresMaxLimit = 5.000000e+01
Attr Super.ACS800.RefSpeed.PresMaxLimit = 2.000000e+03
Attr Super.ACS800.PowerUpTime = 1.500000e+01
Attr Super.ACS800.AlarmLocalMod = "Frequency converter control location is local, "
Attr Super.ACS800.AlarmTripped = "Frequency converter tripped, you must reset, "
Attr Super.ACS800.AlarmFanOld = "Replace cooling fan in frequency converter, "
Attr Super.ACS800.AlarmLocalMod = "Frequency converter is in local mode, "
Attr Super.ACS800.AlarmTripped = "Frequency converter tripped, reset is required, "
Attr Super.ACS800.AlarmFanOld = "Maintenance replace of cooling fan in converter required, "
Attr Super.ACS800.AlarmWarning = "Frequency converter warning, "
Attr Super.ACS800.AlarmError = "Frequency converter error, "
Attr Super.ACS800.DefTrend = "ABB:Class-ABB_ACS800PumpAggr-Template.Super.ACS800.PlotGroup"
......@@ -21928,6 +21931,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.PlotGroup.YUnit[2] = "A"
Attr Super.ACS800.PlotGroup.NumPoints = 478
Attr Super.SafetySwitch.AlarmText = "Safety switch is off, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1
......@@ -22046,10 +22052,10 @@ ABB ACS800 Aggregate
EndObject
EndObject
Object Template ABB_ACS800FanAggr 2151383040 01-JAN-1970 01:00:00.00
Body RtBody 16-DEC-2005 16:23:59.95
Attr Super.AlarmTextToOften = "Start up converter (power on) to often, wait before try again "
Attr Super.AlarmTextPowOnNotOk = "Check interlocks! Start up (power on) converter is not allowed "
Attr Super.AlarmTextStartNoOk = "Power is not on, start is not allowed "
Body RtBody 23-JAN-2006 09:30:28.13
Attr Super.AlarmTextToOften = "Power not yet ready for restart, wait before retry, "
Attr Super.AlarmTextPowOnNotOk = "Power interlocked, "
Attr Super.AlarmTextStartNoOk = "Power is not on, "
Attr Super.CircuitBreaker.AlarmText = "Circuit breaker tripped, "
Attr Super.Contactor.FbTimeLimit = 1.000000e+00
Attr Super.Contactor.AlarmText = "Feedback contactor lost, "
......@@ -22077,9 +22083,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.RefSpeed.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.O_REF"
Attr Super.ACS800.RefSpeed.PresMaxLimit = 2.000000e+03
Attr Super.ACS800.PowerUpTime = 1.500000e+01
Attr Super.ACS800.AlarmLocalMod = "Frequency converter control location is local, "
Attr Super.ACS800.AlarmTripped = "Frequency converter tripped, you must reset, "
Attr Super.ACS800.AlarmFanOld = "Replace cooling fan in frequency converter, "
Attr Super.ACS800.AlarmLocalMod = "Frequency converter is in local mode, "
Attr Super.ACS800.AlarmTripped = "Frequency converter tripped, reset is required, "
Attr Super.ACS800.AlarmFanOld = "Maintenance replace of cooling fan in converter required, "
Attr Super.ACS800.AlarmWarning = "Frequency converter warning, "
Attr Super.ACS800.AlarmError = "Frequency converter error, "
Attr Super.ACS800.DefTrend = "ABB:Class-ABB_ACS800FanAggr-Template.Super.ACS800.PlotGroup"
......@@ -22120,6 +22126,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.PlotGroup.YUnit[2] = "A"
Attr Super.ACS800.PlotGroup.NumPoints = 478
Attr Super.SafetySwitch.AlarmText = "Safety switch is off, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1
......@@ -22161,7 +22170,7 @@ ABB ACS800 Aggregate
! The object is configured under a PbSlave object in the node hierarchy.
! Connect the function object to an object of class or subclass of
! ABB_ACS800_1 with the IoConnect method.
!
!
! Fr att anpassa denna PPO5 konfigurations uppbyggnad (I/O) i Proview
! krvs instllningar i omriktarens parameterinstllningar.
!
......@@ -22188,7 +22197,7 @@ ABB ACS800 Aggregate
!
! 98.02 = FIELDBUS Serial communication
! 98.07 = ABB Drives Communication profile
!
!
! Se also
! 16.01 = ? Run enable parameter
! 20.01 = ? Limits min speed
......@@ -22200,8 +22209,8 @@ ABB ACS800 Aggregate
! 105, dvs driftvrdet "01.05" som r rvrdet momentet i omriktaren. Denna
! signal r i sin tur knuten till signalnamnet "ActTorque" i objektet
! "ABB_ACS800_1".
!
! OBS!
!
! OBS
! vriga instllningar i omriktaren som mste till fr en fungerande
! kommunikation beaktas inte hr.
!
......@@ -22298,7 +22307,7 @@ ABB ACS800 Aggregate
EndObject
!/**
! Fault word 1 (PZD5 Parameter 51.10 = 305) connected to "FaultWord1".
!*/
!*/
Object I_PZD5 $Attribute 9 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "I_PZD5"
......@@ -22308,7 +22317,7 @@ ABB ACS800 Aggregate
EndObject
!/**
! Fault word 2 (PZD6 Parameter 51.12 = 306) connected to "FaultWord2".
!*/
!*/
Object I_PZD6 $Attribute 14 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "I_PZD6"
......@@ -22318,7 +22327,7 @@ ABB ACS800 Aggregate
EndObject
!/**
! DI6-1 Status Input card on converter (PZD7 Parameter 51.14 = 117) connected to "Di6_1".
!*/
!*/
Object I_PZD7 $Attribute 13 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "I_PZD7"
......@@ -22328,7 +22337,7 @@ ABB ACS800 Aggregate
EndObject
!/**
! Alarm word 5 (PZD8 Parameter 51.16 = 318) connected to "AlarmWord5".
!*/
!*/
Object I_PZD8 $Attribute 12 12-OCT-2005 12:58:20.00
Body SysBody 01-JAN-1970 01:00:00.00
Attr PgmName = "I_PZD8"
......
......@@ -57885,11 +57885,12 @@ Alarm HH, H, L, LL"
EndObject
EndObject
Object Template BaseActuatorA 2176286720 01-JAN-1970 01:00:00.00
Body RtBody 03-OCT-2005 14:10:42.58
Body RtBody 23-JAN-2006 09:31:54.36
Attr Order.Unit = "%"
Attr Order.PresMaxLimit = 1.000000e+02
Attr Position.PresMaxLimit = 1.000000e+02
Attr Mode.OpNoLocal = 1
Attr Mode.OpMaxRefMan = 1.000000e+02
Attr Mode.AlarmLocalMode = "Local mode is activated, "
Attr MaxPosDiff = 5.000000e+00
Attr DiffAlarmDelay = 1.000000e+01
......@@ -66517,12 +66518,13 @@ Alarm HH, H, L, LL"
EndObject
EndObject
Object Template BaseCValve 2177073152 01-JAN-1970 01:00:00.00
Body RtBody 03-OCT-2005 14:10:21.13
Body RtBody 23-JAN-2006 09:34:07.12
Attr Actuator.GraphConfiguration = 4
Attr Actuator.Order.Unit = "%"
Attr Actuator.Order.PresMaxLimit = 1.000000e+02
Attr Actuator.Position.PresMaxLimit = 1.000000e+02
Attr Actuator.Mode.OpNoLocal = 1
Attr Actuator.Mode.OpMaxRefMan = 1.000000e+02
Attr Actuator.Mode.AlarmLocalMode = "Local mode is activated, "
Attr Actuator.MaxPosDiff = 5.000000e+00
Attr Actuator.DiffAlarmDelay = 1.000000e+01
......@@ -77365,7 +77367,10 @@ Alarm HH, H, L, LL"
EndObject
EndObject
Object Template BaseMotor 2177859584 01-JAN-1970 01:00:00.00
Body RtBody 01-DEC-2005 08:56:14.11
Body RtBody 23-JAN-2006 09:32:17.05
Attr GraphConfiguration = 2
Attr DisableTempSwitch = 1
Attr TempSwitch.Super.DisableSwitch = 1
Attr TempSwitch.Super.AlarmText = "High motor temperature, "
Attr DisableTempSensor = 1
Attr TempSensor.Super.DisableValue = 1
......@@ -89907,7 +89912,7 @@ Safety switch"
EndObject
EndObject
Object Template BaseMotorAggr 2182316032 01-JAN-1970 01:00:00.00
Body RtBody 01-DEC-2005 08:57:09.70
Body RtBody 23-JAN-2006 09:32:37.70
Attr Contactor.Order.Description = "Energize contactor"
Attr Contactor.Feedback.Description = "Contactor is energized"
Attr Contactor.FbTimeLimit = 1.000000e+00
......@@ -89921,8 +89926,12 @@ Safety switch"
Attr Mode.Alarm1LocalMod = "Local mode is activated, remote control is not allowed, "
Attr Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Mode.AlarmNotManOrd = "Automode active. Manual start/stop order is not allowed, "
Attr Motor.GraphConfiguration = 2
Attr Motor.DisableTempSwitch = 1
Attr Motor.TempSwitch.Super.DisableSwitch = 1
Attr Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Motor.DisableTempSensor = 1
Attr Motor.TempSensor.Super.DisableValue = 1
Attr Motor.TempSensor.Super.Value.Unit = "C"
Attr Motor.TempSensor.Super.Value.PresMaxLimit = 1.500000e+02
Attr Motor.TempSensor.Super.LimitHH.AlarmText = "High High motor temperature, "
......@@ -95266,7 +95275,7 @@ Motor aggregat"
EndObject
EndObject
Object Template BaseFanAggr 2183364608 01-JAN-1970 01:00:00.00
Body RtBody 16-DEC-2005 15:58:47.74
Body RtBody 23-JAN-2006 09:32:57.88
Attr Super.Contactor.Order.Description = "Energize contactor"
Attr Super.Contactor.Feedback.Description = "Contactor is energized"
Attr Super.Contactor.FbTimeLimit = 1.000000e+00
......@@ -95280,8 +95289,12 @@ Motor aggregat"
Attr Super.Mode.Alarm1LocalMod = "Local mode is activated, remote control is not allowed, "
Attr Super.Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Super.Mode.AlarmNotManOrd = "Automode active. Manual start/stop order is not allowed, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1
Attr Super.Motor.TempSensor.Super.Value.Unit = "C"
Attr Super.Motor.TempSensor.Super.Value.PresMaxLimit = 1.500000e+02
Attr Super.Motor.TempSensor.Super.LimitHH.AlarmText = "High High motor temperature, "
......@@ -95380,7 +95393,7 @@ Motor aggregat"
EndObject
EndObject
Object Template BasePumpAggr 2184675328 01-JAN-1970 01:00:00.00
Body RtBody 16-DEC-2005 15:58:11.81
Body RtBody 23-JAN-2006 09:33:14.26
Attr Super.Contactor.Order.Description = "Energize contactor"
Attr Super.Contactor.Feedback.Description = "Contactor is energized"
Attr Super.Contactor.FbTimeLimit = 1.000000e+00
......@@ -95394,8 +95407,12 @@ Motor aggregat"
Attr Super.Mode.Alarm1LocalMod = "Local mode is activated, remote control is not allowed, "
Attr Super.Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Super.Mode.AlarmNotManOrd = "Automode active. Manual start/stop order is not allowed, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1
Attr Super.Motor.TempSensor.Super.Value.Unit = "C"
Attr Super.Motor.TempSensor.Super.Value.PresMaxLimit = 1.500000e+02
Attr Super.Motor.TempSensor.Super.LimitHH.AlarmText = "High High motor temperature, "
......@@ -96168,7 +96185,7 @@ Motor aggregat"
EndObject
EndObject
Object Template BaseMotorIncrDecrAggr 2185199616 01-JAN-1970 01:00:00.00
Body RtBody 16-DEC-2005 15:56:50.10
Body RtBody 23-JAN-2006 09:33:39.14
Attr ContactorIncr.Order.Description = "Energize contactor"
Attr ContactorIncr.Feedback.Description = "Contactor is energized"
Attr ContactorIncr.FbTimeLimit = 1.000000e+00
......@@ -96188,6 +96205,9 @@ Motor aggregat"
Attr Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Mode.AlarmNotManOrd = "Automode active. Manual order is not allowed, "
Attr Mode.AlarmOrderTimeOut = "Timeout, limit switch not reached, "
Attr Motor.GraphConfiguration = 2
Attr Motor.DisableTempSwitch = 1
Attr Motor.TempSwitch.Super.DisableSwitch = 1
Attr Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Motor.DisableTempSensor = 1
Attr Motor.TempSensor.Super.DisableValue = 1
......@@ -38,12 +38,12 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
EndObject
EndObject
Object Template Ventim_Valve_VM3001 2147975168 06-OCT-2005 09:28:20.00
Body RtBody 01-JAN-1970 01:00:00.00
Body RtBody 23-JAN-2006 09:22:29.15
Attr Super.Super.Specification = "Ventim Butterfly valve VM3001"
Attr Super.Super.DataSheet = "$pwr_lang/dsh/ventim_valve_vm3001.pdf"
Attr Super.SwitchOpen.Description = "Valve is open"
Attr Super.SwitchClosed.Description = "Valve is closed"
Attr Super.AlarmText = "Valve error"
Attr Super.AlarmText = "Valve error, "
EndBody
EndObject
EndObject
......@@ -118,7 +118,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
EndObject
EndObject
Object Template Bernard_Actuator_OA 2150858752 06-OCT-2005 09:28:20.00
Body RtBody 06-OCT-2005 09:45:37.69
Body RtBody 23-JAN-2006 09:25:04.66
Attr Super.Super.Specification = "Bernard stlldon typ OA"
Attr Super.Super.DataSheet = "$pwr_lang/dsh/bernard_actuator_oa.html"
Attr Super.GraphConfiguration = 4
......@@ -127,6 +127,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Position.Unit = "%"
Attr Super.Position.PresMaxLimit = 1.000000e+02
Attr Super.Mode.OpNoLocal = 1
Attr Super.Mode.OpMaxRefMan = 1.000000e+02
Attr Super.Mode.AlarmLocalMode = "Local mode is activated, "
Attr Super.MaxPosDiff = 5.000000e+00
Attr Super.DiffAlarmDelay = 1.000000e+01
......@@ -249,9 +250,9 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Super.LimitHH.Limit = 9.500000e+01
Attr Super.Super.LimitH.AlarmText = "High limit exceeded, levelsensor "
Attr Super.Super.LimitH.Limit = 9.000000e+01
Attr Super.Super.LimitL.AlarmText = "Beyond Low limit, levelsensor "
Attr Super.Super.LimitL.AlarmText = "Below Low limit, levelsensor "
Attr Super.Super.LimitL.Limit = 1.000000e+01
Attr Super.Super.LimitLL.AlarmText = "Beyond LowLow limit, levelsensor "
Attr Super.Super.LimitLL.AlarmText = "Below LowLow limit, levelsensor "
Attr Super.Super.LimitLL.Limit = 5.000000e+00
Attr Super.Super.Trend.Multiple = 1
Attr Super.Super.Trend.DataName = "OtherManufacturer:Class-Impac_TempSensor_IN300-Template.Super.Super.Value.ActualValue"
......@@ -377,9 +378,9 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Super.LimitHH.Limit = 9.500000e+01
Attr Super.Super.LimitH.AlarmText = "High limit exceeded, levelsensor "
Attr Super.Super.LimitH.Limit = 9.000000e+01
Attr Super.Super.LimitL.AlarmText = "Beyond Low limit, levelsensor "
Attr Super.Super.LimitL.AlarmText = "Below Low limit, levelsensor "
Attr Super.Super.LimitL.Limit = 1.000000e+01
Attr Super.Super.LimitLL.AlarmText = "Beyond LowLow limit, levelsensor "
Attr Super.Super.LimitLL.AlarmText = "Below LowLow limit, levelsensor "
Attr Super.Super.LimitLL.Limit = 5.000000e+00
Attr Super.Super.Trend.Multiple = 1
Attr Super.Super.Trend.DataName = "OtherManufacturer:Class-Mobrey_LevelSensor_MSP422-Template.Super.Super.Value.ActualValue"
......@@ -467,9 +468,9 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Super.LimitHH.Limit = 9.500000e+01
Attr Super.Super.LimitH.AlarmText = "High limit exceeded, pressuresensor "
Attr Super.Super.LimitH.Limit = 9.000000e+01
Attr Super.Super.LimitL.AlarmText = "Beyond Low limit, pressuresensor "
Attr Super.Super.LimitL.AlarmText = "Below Low limit, pressuresensor "
Attr Super.Super.LimitL.Limit = 1.000000e+01
Attr Super.Super.LimitLL.AlarmText = "Beyond LowLow limit, pressuresensor "
Attr Super.Super.LimitLL.AlarmText = "Below LowLow limit, pressuresensor "
Attr Super.Super.LimitLL.Limit = 5.000000e+00
Attr Super.Super.Trend.Multiple = 1
Attr Super.Super.Trend.DataName = "OtherManufacturer:Class-Klay_PressureSensor_Series2000-Template.Super.Super.Value.ActualValue"
......