Olof Johansson authored
Some versions of PWRficient 1682M have an interrupt controller in which the first register in each pair for interrupt sources doesn't always read with the right polarity/sense values. To work around this, keep a software copy of the register instead. Since it's not modified from the mpic itself, it's a feasible solution. Still, keep it under a config option to avoid wasting memory on other platforms. Signed-off-by: Olof Johansson <olof@lixom.net> Signed-off-by: Paul Mackerras <paulus@samba.org>
0d72ba93