Heiner Kallweit authored
Currently link up can't be detected in forced mode if polling isn't used. Only link up interrupt source we have is aneg complete which isn't applicable in forced mode. Therefore we have to use energy-on as link up indicator. Fixes: 73654945 ("net: phy: smsc: skip ENERGYON interrupt if disabled") Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>