According to the ABI docs hysteresis values are represented as offsets to threshold values. Current implementation represents hysteresis values as absolute values which is wrong. Nevertheless the device stores them as absolute values and the datasheet refers to them as clear thresholds. Fix the reading and writing of hysteresis values by including thresholds into calculations. Hysteresis values that result in threshold clear values that are out of limits will be truncated. To check that the threshold clear values are correct, registers are read out using i2ctransfer and the corresponding temperature and relative humidity thresholds are calculated using the formulas in the datasheet. Fixes: 3ad0e7e5 ("iio: humidity: hdc3020: add threshold events support") Signed-off-by: Dimitri Fedrau <dima.fedrau@gmail.com> Reviewed-by: Javier Carrasco <javier.carrasco.cruz@gmail.com> Link: https://lore.kernel.org/r/20240605192136.38146-1-dima.fedrau@gmail.com Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>