• Michael Walle's avatar
    arm64: dts: ls1028a: fix ENETC PTP clock input · d0570a57
    Michael Walle authored
    On the LS1028A the ENETC reference clock is connected to 4th HWA output,
    see Figure 7 "Clock subsystem block diagram".
    
    The PHC may run with a wrong frequency. ptp_qoriq_auto_config() will read
    the clock speed of the clock given in the device tree. It is likely that,
    on the reference board this wasn't noticed because both clocks have the
    same frequency. But this must not be always the case. Fix it.
    
    Fixes: 49401003 ("arm64: dts: fsl: ls1028a: add ENETC 1588 timer node")
    Signed-off-by: default avatarMichael Walle <michael@walle.cc>
    Signed-off-by: default avatarShawn Guo <shawnguo@kernel.org>
    d0570a57