Richard Fitzgerald authored
Use the late-read buffer in the CS35L56 SoundWire interface to read OTP memory. The OTP memory has a longer access latency than chip registers and cannot guarantee to return the data value in the SoundWire control response if the bus clock is >4.8 MHz. The Cirrus SoundWire peripheral IP exposes the bridge-to-bus read buffer and status bits. For a read from OTP the bridge status bits are polled to wait for the OTP data to be loaded into the read buffer and the data is then read from there. Signed-off-by: Richard Fitzgerald <rf@opensource.cirrus.com> Fixes: e1830f66 ("ASoC: cs35l56: Add helper functions for amp calibration") Link: https://patch.msgid.link/20240805140839.26042-1-rf@opensource.cirrus.comSigned-off-by: Mark Brown <broonie@kernel.org>
e42066df