• Brandon Wyman's avatar
    hwmon: (pmbus) Add Vin unit off handling · a5436af5
    Brandon Wyman authored
    If there is an input undervoltage fault, reported in STATUS_INPUT
    command response, there is quite likely a "Unit Off For Insufficient
    Input Voltage" condition as well.
    
    Add a constant for bit 3 of STATUS_INPUT. Update the Vin limit
    attributes to include both bits in the mask for clearing faults.
    
    If an input undervoltage fault occurs, causing a unit off for
    insufficient input voltage, but the unit is off bit is not cleared, the
    STATUS_WORD will not be updated to clear the input fault condition.
    Including the unit is off bit (bit 3) allows for the input fault
    condition to completely clear.
    Signed-off-by: default avatarBrandon Wyman <bjwyman@gmail.com>
    Link: https://lore.kernel.org/r/20220317232123.2103592-1-bjwyman@gmail.com
    Fixes: b4ce237b ("hwmon: (pmbus) Introduce infrastructure to detect sensors and limit registers")
    [groeck: Dropped unnecessary ()]
    Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>