iio: adc: ad_sigma_delta: Fix IRQ issue by setting IRQ_DISABLE_UNLAZY flag
The Sigma-Delta ADCs supported by this driver can use SDO as an interrupt line to indicate the completion of a conversion. However, some devices cannot properly detect the completion of a conversion by an interrupt. This is for the reason mentioned in the following commit. commit e9849777 ("genirq: Add flag to force mask in disable_irq[_nosync]()") A read operation is performed by an extra interrupt before the completion of a conversion. At this time, the value read from the ADC data register is the same as the previous conversion result. This patch fixes the issue by setting IRQ_DISABLE_UNLAZY flag. Fixes: 0c6ef985 ("iio: adc: ad7791: fix IRQ flags") Fixes: 1a913270 ("iio: adc: ad7793: Fix IRQ flag") Fixes: e081102f ("iio: adc: ad7780: Fix IRQ flag") Fixes: 89a86da5 ("iio: adc: ad7192: Add IRQ flag") Fixes: 79ef9149 ("iio: adc: ad7124: Set IRQ type to falling") Signed-off-by: Masahiro Honda <honda@mechatrax.com> Link: https://lore.kernel.org/r/20230518110816.248-1-honda@mechatrax.com Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>