pwm: bcm2835: Improve period and duty cycle calculation
With an input clk rate bigger than 2000000000, scaler would have been zero which then would have resulted in a division by zero. Also the originally implemented algorithm divided by the result of a division. This nearly always looses precision. Consider a requested period of 1000000 ns. With an input clock frequency of 32786885 Hz the hardware was configured with an actual period of 983869.007 ns (PERIOD = 32258) while the hardware can provide 1000003.508 ns (PERIOD = 32787). And note if the input clock frequency was 32786886 Hz instead, the hardware was configured to 1016656.477 ns (PERIOD = 33333) while the optimal setting results in 1000003.477 ns (PERIOD = 32787). This patch implements proper range checking and only divides once for the calculation of period (and similar for duty_cycle). Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Reviewed-by: Lino Sanfilippo <LinoSanfilippo@gmx.de> Tested-by: Lino Sanfilippo <LinoSanfilippo@gmx.de> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>