adding mandatory aliases for derived tables as per SQL-99

doing it in sql_yacc.yy does not work
this commit contains fixes for other tests
there are fixes in subselect test which will have to be changed
once fix_fields is fixed to work with aliased derived tables
parent c6e6fa8f
...@@ -262,4 +262,5 @@ ...@@ -262,4 +262,5 @@
#define ER_CYCLIC_REFERENCE 1243 #define ER_CYCLIC_REFERENCE 1243
#define ER_AUTO_CONVERT 1244 #define ER_AUTO_CONVERT 1244
#define ER_ILLEGAL_REFERENCE 1245 #define ER_ILLEGAL_REFERENCE 1245
#define ER_ERROR_MESSAGES 246 #define ER_DERIVED_MUST_HAVE_ALIAS 1246
#define ER_ERROR_MESSAGES 247
...@@ -17,32 +17,32 @@ select t1.a,t4.y from t1,(select t2.a as y from t2,(select t3.b from t3 where t3 ...@@ -17,32 +17,32 @@ select t1.a,t4.y from t1,(select t2.a as y from t2,(select t3.b from t3 where t3
a y a y
3 3 3 3
3 3 3 3
SELECT a FROM (SELECT 1 FROM (SELECT 1) HAVING a=1); SELECT a FROM (SELECT 1 FROM (SELECT 1) a HAVING a=1) b;
Unknown column 'a' in 'having clause' Unknown column 'a' in 'having clause'
SELECT a,b as a FROM (SELECT '1' as a,'2' as b) HAVING a=1; SELECT a,b as a FROM (SELECT '1' as a,'2' as b) b HAVING a=1;
Column: 'a' in having clause is ambiguous Column: 'a' in having clause is ambiguous
SELECT a,2 as a FROM (SELECT '1' as a) HAVING a=2; SELECT a,2 as a FROM (SELECT '1' as a) b HAVING a=2;
a a a a
1 2 1 2
SELECT a,2 as a FROM (SELECT '1' as a) HAVING a=1; SELECT a,2 as a FROM (SELECT '1' as a) b HAVING a=1;
a a a a
SELECT 1 FROM (SELECT 1) WHERE a=2; SELECT 1 FROM (SELECT 1) a WHERE a=2;
Unknown column 'a' in 'where clause' Unknown column 'a' in 'where clause'
SELECT (SELECT 1) as a FROM (SELECT 1 FROM t1 HAVING a=1); SELECT (SELECT 1) as a FROM (SELECT 1 FROM t1 HAVING a=1) as a;
Unknown column 'a' in 'having clause' Unknown column 'a' in 'having clause'
drop table if exists t1.t2,t3; drop table if exists t1.t2,t3;
select * from (select 1); select * from (select 1) as a;
1 1
1 1
select a from (select 1 as a); select a from (select 1 as a) as b;
a a
1 1
select 1 from (select 1); select 1 from (select 1) as a;
1 1
1 1
drop table if exists t1; drop table if exists t1;
create table t1(a int not null, t char(8), index(a)); create table t1(a int not null, t char(8), index(a));
SELECT * FROM (SELECT * FROM t1) ORDER BY a ASC LIMIT 0,20; SELECT * FROM (SELECT * FROM t1) as b ORDER BY a ASC LIMIT 0,20;
a t a t
1 1 1 1
2 2 2 2
...@@ -65,6 +65,6 @@ a t ...@@ -65,6 +65,6 @@ a t
19 19 19 19
20 20 20 20
drop table if exists t1; drop table if exists t1;
SELECT * FROM (SELECT (SELECT * FROM (SELECT 1 as a))); SELECT * FROM (SELECT (SELECT * FROM (SELECT 1 as a) as a )) as b;
(SELECT * FROM (SELECT 1 as a)) (SELECT * FROM (SELECT 1 as a) as a )
1 1
SELECT 1 FROM (SELECT 1) GROUP BY SUM(1); SELECT 1 FROM (SELECT 1) as a GROUP BY SUM(1);
Invalid use of group function Invalid use of group function
drop table if exists t1,t2,t3; drop table if exists t1,t2,t3;
CREATE TABLE t1 ( CREATE TABLE t1 (
......
...@@ -168,7 +168,7 @@ test2 2 2 ...@@ -168,7 +168,7 @@ test2 2 2
SELECT FOUND_ROWS(); SELECT FOUND_ROWS();
FOUND_ROWS() FOUND_ROWS()
2 2
SELECT SQL_CALC_FOUND_ROWS 1 FROM (SELECT 1) LIMIT 0; SELECT SQL_CALC_FOUND_ROWS 1 FROM (SELECT 1) as a LIMIT 0;
1 1
SELECT FOUND_ROWS(); SELECT FOUND_ROWS();
FOUND_ROWS() FOUND_ROWS()
......
...@@ -8,29 +8,29 @@ SELECT (SELECT 1) UNION SELECT (SELECT 2); ...@@ -8,29 +8,29 @@ SELECT (SELECT 1) UNION SELECT (SELECT 2);
SELECT (SELECT (SELECT 0 UNION SELECT 0)); SELECT (SELECT (SELECT 0 UNION SELECT 0));
(SELECT (SELECT 0 UNION SELECT 0)) (SELECT (SELECT 0 UNION SELECT 0))
0 0
SELECT (SELECT 1 FROM (SELECT 1) HAVING a=1) as a; SELECT (SELECT 1 FROM (SELECT 1) as b HAVING a=1) as a;
Reference 'a' not supported (forward reference in item list) Reference 'a' not supported (forward reference in item list)
SELECT (SELECT 1 FROM (SELECT 1) HAVING b=1) as a,(SELECT 1 FROM (SELECT 1) HAVING a=1) as b; SELECT (SELECT 1 FROM (SELECT 1) as b HAVING b=1) as a,(SELECT 1 FROM (SELECT 1) as c HAVING a=1) as b;
Reference 'b' not supported (forward reference in item list) Reference 'b' not supported (forward reference in item list)
SELECT (SELECT 1),MAX(1) FROM (SELECT 1); SELECT (SELECT 1),MAX(1) FROM (SELECT 1) as a;
(SELECT 1) MAX(1) (SELECT 1) MAX(1)
1 1 1 1
SELECT (SELECT a) as a; SELECT (SELECT a) as a;
Reference 'a' not supported (forward reference in item list) Reference 'a' not supported (forward reference in item list)
EXPLAIN SELECT 1 FROM (SELECT 1 as a) HAVING (SELECT a)=1; EXPLAIN SELECT 1,a FROM (SELECT 1 as a) as b HAVING (SELECT a)=1;
id select_type table type possible_keys key key_len ref rows Extra id select_type table type possible_keys key key_len ref rows Extra
1 PRIMARY <derived2> system NULL NULL NULL NULL 1 1 PRIMARY <derived2> system NULL NULL NULL NULL 1
3 DEPENDENT SUBSELECT No tables used 3 DEPENDENT SUBSELECT No tables used
2 DERIVED No tables used 2 DERIVED No tables used
SELECT 1 FROM (SELECT 1 as a) HAVING (SELECT a)=1; SELECT 1,a FROM (SELECT 1 as a) as b HAVING (SELECT a)=1;
1 1 a
1 1 1
SELECT (SELECT 1), a; SELECT (SELECT 1), a;
Unknown column 'a' in 'field list' Unknown column 'a' in 'field list'
SELECT 1 as a FROM (SELECT 1) HAVING (SELECT a)=1; SELECT 1 as a FROM (SELECT 1) as b HAVING (SELECT a)=1;
a a
1 1
SELECT 1 FROM (SELECT (SELECT a)); SELECT 1 FROM (SELECT (SELECT a) b) c;
Unknown column 'a' in 'field list' Unknown column 'a' in 'field list'
drop table if exists t1,t2,t3,t4,t5,t6,t7,t8; drop table if exists t1,t2,t3,t4,t5,t6,t7,t8;
create table t1 (a int); create table t1 (a int);
...@@ -308,7 +308,7 @@ SELECT numeropost,maxnumrep FROM t1 WHERE exists (SELECT 1 FROM t2 WHERE (mot='j ...@@ -308,7 +308,7 @@ SELECT numeropost,maxnumrep FROM t1 WHERE exists (SELECT 1 FROM t2 WHERE (mot='j
numeropost maxnumrep numeropost maxnumrep
43506 2 43506 2
40143 1 40143 1
SELECT (SELECT 1) as a FROM (SELECT 1 FROM t1 HAVING a=1); SELECT (SELECT 1) as a FROM (SELECT 1 FROM t1 HAVING a=1) b;
Unknown column 'a' in 'having clause' Unknown column 'a' in 'having clause'
SELECT 1 IN (SELECT 1 FROM t2 HAVING a); SELECT 1 IN (SELECT 1 FROM t2 HAVING a);
Unknown column 'a' in 'having clause' Unknown column 'a' in 'having clause'
...@@ -357,7 +357,7 @@ Subselect returns more than 1 record ...@@ -357,7 +357,7 @@ Subselect returns more than 1 record
drop table t1; drop table t1;
CREATE TABLE t1 (field char(1) NOT NULL DEFAULT 'b'); CREATE TABLE t1 (field char(1) NOT NULL DEFAULT 'b');
INSERT INTO t1 VALUES (); INSERT INTO t1 VALUES ();
SELECT field FROM t1 WHERE 1=(SELECT 1 UNION ALL SELECT 1 FROM (SELECT 1) HAVING field='b'); SELECT field FROM t1 WHERE 1=(SELECT 1 UNION ALL SELECT 1 FROM (SELECT 1) a HAVING field='b');
Subselect returns more than 1 record Subselect returns more than 1 record
drop table t1; drop table t1;
CREATE TABLE `t1` ( CREATE TABLE `t1` (
...@@ -387,9 +387,9 @@ id select_type table type possible_keys key key_len ref rows Extra ...@@ -387,9 +387,9 @@ id select_type table type possible_keys key key_len ref rows Extra
drop table t1; drop table t1;
CREATE TABLE t1 (a int(1)); CREATE TABLE t1 (a int(1));
INSERT INTO t1 VALUES (1); INSERT INTO t1 VALUES (1);
SELECT 1 FROM (SELECT a FROM t1) HAVING (SELECT a)=1; SELECT 1,a FROM (SELECT a FROM t1) b HAVING (SELECT b.a)=1;
1 1 a
1 1 1
drop table t1; drop table t1;
create table t1 (a int NOT NULL, b int, primary key (a)); create table t1 (a int NOT NULL, b int, primary key (a));
create table t2 (a int NOT NULL, b int, primary key (a)); create table t2 (a int NOT NULL, b int, primary key (a));
......
...@@ -9,19 +9,19 @@ CREATE TABLE t3 (a int not null, b char (10) not null); ...@@ -9,19 +9,19 @@ CREATE TABLE t3 (a int not null, b char (10) not null);
insert into t3 values (3,'f'),(4,'y'),(5,'z'),(6,'c'); insert into t3 values (3,'f'),(4,'y'),(5,'z'),(6,'c');
select t1.a,t4.y from t1,(select t2.a as y from t2,(select t3.b from t3 where t3.a>3) as t5 where t2.b=t5.b) as t4 where t1.a = t4.y; select t1.a,t4.y from t1,(select t2.a as y from t2,(select t3.b from t3 where t3.a>3) as t5 where t2.b=t5.b) as t4 where t1.a = t4.y;
--error 1054 --error 1054
SELECT a FROM (SELECT 1 FROM (SELECT 1) HAVING a=1); SELECT a FROM (SELECT 1 FROM (SELECT 1) a HAVING a=1) b;
--error 1052 --error 1052
SELECT a,b as a FROM (SELECT '1' as a,'2' as b) HAVING a=1; SELECT a,b as a FROM (SELECT '1' as a,'2' as b) b HAVING a=1;
SELECT a,2 as a FROM (SELECT '1' as a) HAVING a=2; SELECT a,2 as a FROM (SELECT '1' as a) b HAVING a=2;
SELECT a,2 as a FROM (SELECT '1' as a) HAVING a=1; SELECT a,2 as a FROM (SELECT '1' as a) b HAVING a=1;
--error 1054 --error 1054
SELECT 1 FROM (SELECT 1) WHERE a=2; SELECT 1 FROM (SELECT 1) a WHERE a=2;
--error 1054 --error 1054
SELECT (SELECT 1) as a FROM (SELECT 1 FROM t1 HAVING a=1); SELECT (SELECT 1) as a FROM (SELECT 1 FROM t1 HAVING a=1) as a;
drop table if exists t1.t2,t3; drop table if exists t1.t2,t3;
select * from (select 1); select * from (select 1) as a;
select a from (select 1 as a); select a from (select 1 as a) as b;
select 1 from (select 1); select 1 from (select 1) as a;
drop table if exists t1; drop table if exists t1;
create table t1(a int not null, t char(8), index(a)); create table t1(a int not null, t char(8), index(a));
disable_query_log; disable_query_log;
...@@ -32,6 +32,6 @@ while ($1) ...@@ -32,6 +32,6 @@ while ($1)
dec $1; dec $1;
} }
enable_query_log; enable_query_log;
SELECT * FROM (SELECT * FROM t1) ORDER BY a ASC LIMIT 0,20; SELECT * FROM (SELECT * FROM t1) as b ORDER BY a ASC LIMIT 0,20;
drop table if exists t1; drop table if exists t1;
SELECT * FROM (SELECT (SELECT * FROM (SELECT 1 as a))); SELECT * FROM (SELECT (SELECT * FROM (SELECT 1 as a) as a )) as b;
-- error 1111 -- error 1111
SELECT 1 FROM (SELECT 1) GROUP BY SUM(1); SELECT 1 FROM (SELECT 1) as a GROUP BY SUM(1);
# #
# Test of group (Failed for Lars Hoss <lh@pbm.de>) # Test of group (Failed for Lars Hoss <lh@pbm.de>)
# #
......
...@@ -84,7 +84,7 @@ INSERT INTO t1 (titre,maxnumrep) VALUES ...@@ -84,7 +84,7 @@ INSERT INTO t1 (titre,maxnumrep) VALUES
('test1','1'),('test2','2'),('test3','3'); ('test1','1'),('test2','2'),('test3','3');
SELECT SQL_CALC_FOUND_ROWS titre,numeropost,maxnumrep FROM t1 WHERE numeropost IN (1,2) ORDER BY maxnumrep DESC LIMIT 0, 1; SELECT SQL_CALC_FOUND_ROWS titre,numeropost,maxnumrep FROM t1 WHERE numeropost IN (1,2) ORDER BY maxnumrep DESC LIMIT 0, 1;
SELECT FOUND_ROWS(); SELECT FOUND_ROWS();
SELECT SQL_CALC_FOUND_ROWS 1 FROM (SELECT 1) LIMIT 0; SELECT SQL_CALC_FOUND_ROWS 1 FROM (SELECT 1) as a LIMIT 0;
SELECT FOUND_ROWS(); SELECT FOUND_ROWS();
SELECT SQL_CALC_FOUND_ROWS * FROM t1 WHERE numeropost > 1 LIMIT 0; SELECT SQL_CALC_FOUND_ROWS * FROM t1 WHERE numeropost > 1 LIMIT 0;
SELECT FOUND_ROWS(); SELECT FOUND_ROWS();
......
...@@ -2,19 +2,19 @@ select (select 2); ...@@ -2,19 +2,19 @@ select (select 2);
SELECT (SELECT 1) UNION SELECT (SELECT 2); SELECT (SELECT 1) UNION SELECT (SELECT 2);
SELECT (SELECT (SELECT 0 UNION SELECT 0)); SELECT (SELECT (SELECT 0 UNION SELECT 0));
-- error 1245 -- error 1245
SELECT (SELECT 1 FROM (SELECT 1) HAVING a=1) as a; SELECT (SELECT 1 FROM (SELECT 1) as b HAVING a=1) as a;
-- error 1245 -- error 1245
SELECT (SELECT 1 FROM (SELECT 1) HAVING b=1) as a,(SELECT 1 FROM (SELECT 1) HAVING a=1) as b; SELECT (SELECT 1 FROM (SELECT 1) as b HAVING b=1) as a,(SELECT 1 FROM (SELECT 1) as c HAVING a=1) as b;
SELECT (SELECT 1),MAX(1) FROM (SELECT 1); SELECT (SELECT 1),MAX(1) FROM (SELECT 1) as a;
-- error 1245 -- error 1245
SELECT (SELECT a) as a; SELECT (SELECT a) as a;
EXPLAIN SELECT 1 FROM (SELECT 1 as a) HAVING (SELECT a)=1; EXPLAIN SELECT 1,a FROM (SELECT 1 as a) as b HAVING (SELECT a)=1;
SELECT 1 FROM (SELECT 1 as a) HAVING (SELECT a)=1; SELECT 1,a FROM (SELECT 1 as a) as b HAVING (SELECT a)=1;
-- error 1054 -- error 1054
SELECT (SELECT 1), a; SELECT (SELECT 1), a;
SELECT 1 as a FROM (SELECT 1) HAVING (SELECT a)=1; SELECT 1 as a FROM (SELECT 1) as b HAVING (SELECT a)=1;
-- error 1054 -- error 1054
SELECT 1 FROM (SELECT (SELECT a)); SELECT 1 FROM (SELECT (SELECT a) b) c;
drop table if exists t1,t2,t3,t4,t5,t6,t7,t8; drop table if exists t1,t2,t3,t4,t5,t6,t7,t8;
create table t1 (a int); create table t1 (a int);
create table t2 (a int, b int); create table t2 (a int, b int);
...@@ -170,7 +170,7 @@ INSERT INTO t2 (mot,topic,date,pseudo) VALUES ('joce','40143','2002-10-22','joce ...@@ -170,7 +170,7 @@ INSERT INTO t2 (mot,topic,date,pseudo) VALUES ('joce','40143','2002-10-22','joce
select numeropost as a FROM t1 GROUP BY (SELECT 1 FROM t1 HAVING a=1); select numeropost as a FROM t1 GROUP BY (SELECT 1 FROM t1 HAVING a=1);
SELECT numeropost,maxnumrep FROM t1 WHERE exists (SELECT 1 FROM t2 WHERE (mot='joce') AND date >= '2002-10-21' AND t1.numeropost = t2.topic) ORDER BY maxnumrep DESC LIMIT 0, 20; SELECT numeropost,maxnumrep FROM t1 WHERE exists (SELECT 1 FROM t2 WHERE (mot='joce') AND date >= '2002-10-21' AND t1.numeropost = t2.topic) ORDER BY maxnumrep DESC LIMIT 0, 20;
-- error 1054 -- error 1054
SELECT (SELECT 1) as a FROM (SELECT 1 FROM t1 HAVING a=1); SELECT (SELECT 1) as a FROM (SELECT 1 FROM t1 HAVING a=1) b;
-- error 1054 -- error 1054
SELECT 1 IN (SELECT 1 FROM t2 HAVING a); SELECT 1 IN (SELECT 1 FROM t2 HAVING a);
SELECT * from t2 where topic IN (SELECT topic FROM t2 GROUP BY date); SELECT * from t2 where topic IN (SELECT topic FROM t2 GROUP BY date);
...@@ -204,7 +204,7 @@ drop table t1; ...@@ -204,7 +204,7 @@ drop table t1;
CREATE TABLE t1 (field char(1) NOT NULL DEFAULT 'b'); CREATE TABLE t1 (field char(1) NOT NULL DEFAULT 'b');
INSERT INTO t1 VALUES (); INSERT INTO t1 VALUES ();
-- error 1240 -- error 1240
SELECT field FROM t1 WHERE 1=(SELECT 1 UNION ALL SELECT 1 FROM (SELECT 1) HAVING field='b'); SELECT field FROM t1 WHERE 1=(SELECT 1 UNION ALL SELECT 1 FROM (SELECT 1) a HAVING field='b');
drop table t1; drop table t1;
# threadhardwarefr7 # threadhardwarefr7
...@@ -230,7 +230,7 @@ drop table t1; ...@@ -230,7 +230,7 @@ drop table t1;
CREATE TABLE t1 (a int(1)); CREATE TABLE t1 (a int(1));
INSERT INTO t1 VALUES (1); INSERT INTO t1 VALUES (1);
SELECT 1 FROM (SELECT a FROM t1) HAVING (SELECT a)=1; SELECT 1,a FROM (SELECT a FROM t1) b HAVING (SELECT b.a)=1;
drop table t1; drop table t1;
#update with subselects #update with subselects
......
...@@ -256,3 +256,253 @@ ...@@ -256,3 +256,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -250,3 +250,253 @@ ...@@ -250,3 +250,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -258,3 +258,253 @@ ...@@ -258,3 +258,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -247,3 +247,4 @@ ...@@ -247,3 +247,4 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -252,3 +252,253 @@ ...@@ -252,3 +252,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -247,3 +247,253 @@ ...@@ -247,3 +247,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -250,3 +250,253 @@ ...@@ -250,3 +250,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -247,3 +247,253 @@ ...@@ -247,3 +247,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -249,3 +249,253 @@ ...@@ -249,3 +249,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -247,3 +247,253 @@ ...@@ -247,3 +247,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -249,3 +249,253 @@ ...@@ -249,3 +249,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -247,3 +247,253 @@ ...@@ -247,3 +247,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -249,3 +249,253 @@ ...@@ -249,3 +249,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -249,3 +249,253 @@ ...@@ -249,3 +249,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -251,3 +251,253 @@ ...@@ -251,3 +251,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -247,3 +247,253 @@ ...@@ -247,3 +247,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -251,3 +251,253 @@ ...@@ -251,3 +251,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s" "Converting column '%s' from %s to %s"
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -250,3 +250,253 @@ ...@@ -250,3 +250,253 @@
" ", " ",
" '%s' %s %s", " '%s' %s %s",
" '%-.64s' (%s)", " '%-.64s' (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -243,3 +243,253 @@ ...@@ -243,3 +243,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -255,3 +255,253 @@ ...@@ -255,3 +255,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -248,3 +248,253 @@ ...@@ -248,3 +248,253 @@
"Cyclic reference on subqueries", "Cyclic reference on subqueries",
"Converting column '%s' from %s to %s", "Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -247,3 +247,253 @@ ...@@ -247,3 +247,253 @@
"Syklisk referens i subselect", "Syklisk referens i subselect",
"Konvertar kolumn '%s' från %s till %s", "Konvertar kolumn '%s' från %s till %s",
"Reference '%-.64s' not supported (%s)", "Reference '%-.64s' not supported (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -252,3 +252,253 @@ ...@@ -252,3 +252,253 @@
"i i", "i i",
" '%s' %s %s", " '%s' %s %s",
" '%-.64s' i (%s)", " '%-.64s' i (%s)",
/* Copyright Abandoned 1997 TCX DataKonsult AB & Monty Program KB & Detron HB
This file is public domain and comes with NO WARRANTY of any kind */
"hashchk",
"isamchk",
"NO",
"YES",
"Can't create file '%-.64s' (errno: %d)",
"Can't create table '%-.64s' (errno: %d)",
"Can't create database '%-.64s'. (errno: %d)",
"Can't create database '%-.64s'. Database exists",
"Can't drop database '%-.64s'. Database doesn't exist",
"Error dropping database (can't delete '%-.64s', errno: %d)",
"Error dropping database (can't rmdir '%-.64s', errno: %d)",
"Error on delete of '%-.64s' (errno: %d)",
"Can't read record in system table",
"Can't get status of '%-.64s' (errno: %d)",
"Can't get working directory (errno: %d)",
"Can't lock file (errno: %d)",
"Can't open file: '%-.64s'. (errno: %d)",
"Can't find file: '%-.64s' (errno: %d)",
"Can't read dir of '%-.64s' (errno: %d)",
"Can't change dir to '%-.64s' (errno: %d)",
"Record has changed since last read in table '%-.64s'",
"Disk full (%s). Waiting for someone to free some space....",
"Can't write, duplicate key in table '%-.64s'",
"Error on close of '%-.64s' (errno: %d)",
"Error reading file '%-.64s' (errno: %d)",
"Error on rename of '%-.64s' to '%-.64s' (errno: %d)",
"Error writing file '%-.64s' (errno: %d)",
"'%-.64s' is locked against change",
"Sort aborted",
"View '%-.64s' doesn't exist for '%-.64s'",
"Got error %d from table handler",
"Table handler for '%-.64s' doesn't have this option",
"Can't find record in '%-.64s'",
"Incorrect information in file: '%-.64s'",
"Incorrect key file for table: '%-.64s'. Try to repair it",
"Old key file for table '%-.64s'; Repair it!",
"Table '%-.64s' is read only",
"Out of memory. Restart daemon and try again (needed %d bytes)",
"Out of sort memory. Increase daemon sort buffer size",
"Unexpected eof found when reading file '%-.64s' (errno: %d)",
"Too many connections",
"Out of memory; Check if mysqld or some other process uses all available memory. If not you may have to use 'ulimit' to allow mysqld to use more memory or you can add more swap space",
"Can't get hostname for your address",
"Bad handshake",
"Access denied for user: '%-.32s@%-.64s' to database '%-.64s'",
"Access denied for user: '%-.32s@%-.64s' (Using password: %s)",
"No Database Selected",
"Unknown command",
"Column '%-.64s' cannot be null",
"Unknown database '%-.64s'",
"Table '%-.64s' already exists",
"Unknown table '%-.64s'",
"Column: '%-.64s' in %-.64s is ambiguous",
"Server shutdown in progress",
"Unknown column '%-.64s' in '%-.64s'",
"'%-.64s' isn't in GROUP BY",
"Can't group on '%-.64s'",
"Statement has sum functions and columns in same statement",
"Column count doesn't match value count",
"Identifier name '%-.100s' is too long",
"Duplicate column name '%-.64s'",
"Duplicate key name '%-.64s'",
"Duplicate entry '%-.64s' for key %d",
"Incorrect column specifier for column '%-.64s'",
"%s near '%-.80s' at line %d",
"Query was empty",
"Not unique table/alias: '%-.64s'",
"Invalid default value for '%-.64s'",
"Multiple primary key defined",
"Too many keys specified. Max %d keys allowed",
"Too many key parts specified. Max %d parts allowed",
"Specified key was too long. Max key length is %d",
"Key column '%-.64s' doesn't exist in table",
"BLOB column '%-.64s' can't be used in key specification with the used table type",
"Too big column length for column '%-.64s' (max = %d). Use BLOB instead",
"Incorrect table definition; There can only be one auto column and it must be defined as a key",
"%s: ready for connections\n",
"%s: Normal shutdown\n",
"%s: Got signal %d. Aborting!\n",
"%s: Shutdown Complete\n",
"%s: Forcing close of thread %ld user: '%-.32s'\n",
"Can't create IP socket",
"Table '%-.64s' has no index like the one used in CREATE INDEX. Recreate the table",
"Field separator argument is not what is expected. Check the manual",
"You can't use fixed rowlength with BLOBs. Please use 'fields terminated by'.",
"The file '%-.64s' must be in the database directory or be readable by all",
"File '%-.80s' already exists",
"Records: %ld Deleted: %ld Skipped: %ld Warnings: %ld",
"Records: %ld Duplicates: %ld",
"Incorrect sub part key. The used key part isn't a string, the used length is longer than the key part or the table handler doesn't support unique sub keys",
"You can't delete all columns with ALTER TABLE. Use DROP TABLE instead",
"Can't DROP '%-.64s'. Check that column/key exists",
"Records: %ld Duplicates: %ld Warnings: %ld",
"INSERT TABLE '%-.64s' isn't allowed in FROM table list",
"Unknown thread id: %lu",
"You are not owner of thread %lu",
"No tables used",
"Too many strings for column %-.64s and SET",
"Can't generate a unique log-filename %-.64s.(1-999)\n",
"Table '%-.64s' was locked with a READ lock and can't be updated",
"Table '%-.64s' was not locked with LOCK TABLES",
"BLOB column '%-.64s' can't have a default value",
"Incorrect database name '%-.100s'",
"Incorrect table name '%-.100s'",
"The SELECT would examine too many records and probably take a very long time. Check your WHERE and use SET OPTION SQL_BIG_SELECTS=1 if the SELECT is ok",
"Unknown error",
"Unknown procedure '%-.64s'",
"Incorrect parameter count to procedure '%-.64s'",
"Incorrect parameters to procedure '%-.64s'",
"Unknown table '%-.64s' in %-.32s",
"Column '%-.64s' specified twice",
"Invalid use of group function",
"Table '%-.64s' uses an extension that doesn't exist in this MySQL version",
"A table must have at least 1 column",
"The table '%-.64s' is full",
"Unknown character set: '%-.64s'",
"Too many tables. MySQL can only use %d tables in a join",
"Too many columns",
"Too big row size. The maximum row size, not counting BLOBs, is %d. You have to change some fields to BLOBs",
"Thread stack overrun: Used: %ld of a %ld stack. Use 'mysqld -O thread_stack=#' to specify a bigger stack if needed",
"Cross dependency found in OUTER JOIN. Examine your ON conditions",
"Column '%-.64s' is used with UNIQUE or INDEX but is not defined as NOT NULL",
"Can't load function '%-.64s'",
"Can't initialize function '%-.64s'; %-.80s",
"No paths allowed for shared library",
"Function '%-.64s' already exist",
"Can't open shared library '%-.64s' (errno: %d %-.64s)",
"Can't find function '%-.64s' in library'",
"Function '%-.64s' is not defined",
"Host '%-.64s' is blocked because of many connection errors. Unblock with 'mysqladmin flush-hosts'",
"Host '%-.64s' is not allowed to connect to this MySQL server",
"You are using MySQL as an anonymous users and anonymous users are not allowed to change passwords",
"You must have privileges to update tables in the mysql database to be able to change passwords for others",
"Can't find any matching row in the user table",
"Rows matched: %ld Changed: %ld Warnings: %ld",
"Can't create a new thread (errno %d). If you are not out of available memory, you can consult the manual for a possible OS-dependent bug",
"Column count doesn't match value count at row %ld",
"Can't reopen table: '%-.64s'",
"Invalid use of NULL value",
"Got error '%-.64s' from regexp",
"Mixing of GROUP columns (MIN(),MAX(),COUNT()...) with no GROUP columns is illegal if there is no GROUP BY clause",
"There is no such grant defined for user '%-.32s' on host '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for table '%-.64s'",
"%-.16s command denied to user: '%-.32s@%-.64s' for column '%-.64s' in table '%-.64s'",
"Illegal GRANT/REVOKE command. Please consult the manual which privileges can be used.",
"The host or user argument to GRANT is too long",
"Table '%-.64s.%-.64s' doesn't exist",
"There is no such grant defined for user '%-.32s' on host '%-.64s' on table '%-.64s'",
"The used command is not allowed with this MySQL version",
"You have an error in your SQL syntax. Check the manual that corresponds to your MySQL server version for the right syntax to use",
"Delayed insert thread couldn't get requested lock for table %-.64s",
"Too many delayed threads in use",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' (%-.64s)",
"Got a packet bigger than 'max_allowed_packet'",
"Got a read error from the connection pipe",
"Got an error from fcntl()",
"Got packets out of order",
"Couldn't uncompress communication packet",
"Got an error reading communication packets",
"Got timeout reading communication packets",
"Got an error writing communication packets",
"Got timeout writing communication packets",
"Result string is longer than max_allowed_packet",
"The used table type doesn't support BLOB/TEXT columns",
"The used table type doesn't support AUTO_INCREMENT columns",
"INSERT DELAYED can't be used with table '%-.64s', because it is locked with LOCK TABLES",
"Incorrect column name '%-.100s'",
"The used table handler can't index column '%-.64s'",
"All tables in the MERGE table are not identically defined",
"Can't write, because of unique constraint, to table '%-.64s'",
"BLOB column '%-.64s' used in key specification without a key length",
"All parts of a PRIMARY KEY must be NOT NULL; If you need NULL in a key, use UNIQUE instead",
"Result consisted of more than one row",
"This table type requires a primary key",
"This version of MySQL is not compiled with RAID support",
"You are using safe update mode and you tried to update a table without a WHERE that uses a KEY column",
"Key '%-.64s' doesn't exist in table '%-.64s'",
"Can't open table",
"The handler for the table doesn't support %s",
"You are not allowed to execute this command in a transaction",
"Got error %d during COMMIT",
"Got error %d during ROLLBACK",
"Got error %d during FLUSH_LOGS",
"Got error %d during CHECKPOINT",
"Aborted connection %ld to db: '%-.64s' user: '%-.32s' host: `%-.64s' (%-.64s)",
"The handler for the table does not support binary table dump",
"Binlog closed, cannot RESET MASTER",
"Failed rebuilding the index of dumped table '%-.64s'",
"Error from master: '%-.64s'",
"Net error reading from master",
"Net error writing to master",
"Can't find FULLTEXT index matching the column list",
"Can't execute the given command because you have active locked tables or an active transaction",
"Unknown system variable '%-.64s'",
"Table '%-.64s' is marked as crashed and should be repaired",
"Table '%-.64s' is marked as crashed and last (automatic?) repair failed",
"Some non-transactional changed tables couldn't be rolled back",
"Multi-statement transaction required more than 'max_binlog_cache_size' bytes of storage. Increase this mysqld variable and try again',
"This operation cannot be performed with a running slave, run SLAVE STOP first",
"This operation requires a running slave, configure slave and do SLAVE START",
"The server is not configured as slave, fix in config file or with CHANGE MASTER TO",
"Could not initialize master info structure, check permisions on master.info",
"Could not create slave thread, check system resources",
"User %-.64s has already more than 'max_user_connections' active connections",
"You may only use constant expressions with SET",
"Lock wait timeout exceeded; Try restarting transaction",
"The total number of locks exceeds the lock table size",
"Update locks cannot be acquired during a READ UNCOMMITTED transaction",
"DROP DATABASE not allowed while thread is holding global read lock",
"CREATE DATABASE not allowed while thread is holding global read lock",
"Wrong arguments to %s",
"%-.32s@%-.64s is not allowed to create new users",
"Incorrect table definition; All MERGE tables must be in the same database",
"Deadlock found when trying to get lock; Try restarting transaction",
"The used table type doesn't support FULLTEXT indexes",
"Cannot add foreign key constraint",
"Cannot add a child row: a foreign key constraint fails",
"Cannot delete a parent row: a foreign key constraint fails",
"Error connecting to master: %-.128s",
"Error running query on master: %-.128s",
"Error when executing command %s: %-.128s",
"Wrong usage of %s and %s",
"The used SELECT statements have a different number of columns",
"Can't execute the query because you have a conflicting read lock",
"Mixing of transactional and non-transactional tables is disabled",
"Option '%s' used twice in statement",
"User '%-.64s' has exceeded the '%s' resource (current value: %ld)",
"Access denied. You need the %-.128s privilege for this operation",
"Variable '%-.64s' is a LOCAL variable and can't be used with SET GLOBAL",
"Variable '%-.64s' is a GLOBAL variable and should be set with SET GLOBAL",
"Variable '%-.64s' doesn't have a default value",
"Variable '%-.64s' can't be set to the value of '%-.64s'",
"Wrong argument type to variable '%-.64s'",
"Variable '%-.64s' can only be set, not read",
"Wrong usage/placement of '%s'",
"This version of MySQL doesn't yet support '%s'",
"Got fatal error %d: '%-.128s' from master when reading data from binary log",
"Wrong foreign key definition for '%-.64s': %s",
"Key reference and table reference doesn't match",
"Subselect returns more than 1 field",
"Subselect returns more than 1 record",
"Unknown prepared statement handler (%ld) given to %s",
"Help database is corrupt or does not exist",
"Cyclic reference on subqueries",
"Converting column '%s' from %s to %s",
"Reference '%-.64s' not supported (%s)",
"Every derived table must have it's own alias"
...@@ -108,7 +108,7 @@ int mysql_derived(THD *thd, LEX *lex, SELECT_LEX_UNIT *unit, TABLE_LIST *t) ...@@ -108,7 +108,7 @@ int mysql_derived(THD *thd, LEX *lex, SELECT_LEX_UNIT *unit, TABLE_LIST *t)
table->tmp_table=TMP_TABLE; table->tmp_table=TMP_TABLE;
if (!lex->describe) if (!lex->describe)
sl->exclude(); sl->exclude();
t->db=(char *)""; t->db=(tables && tables->db) ? tables->db : (char *)"";
t->derived=(SELECT_LEX *)0; // just in case ... t->derived=(SELECT_LEX *)0; // just in case ...
} }
} }
......
...@@ -3404,8 +3404,15 @@ TABLE_LIST *st_select_lex::add_table_to_list(Table_ident *table, ...@@ -3404,8 +3404,15 @@ TABLE_LIST *st_select_lex::add_table_to_list(Table_ident *table,
} }
if (!alias) /* Alias is case sensitive */ if (!alias) /* Alias is case sensitive */
{
if (table->sel)
{
net_printf(thd,ER_DERIVED_MUST_HAVE_ALIAS);
DBUG_RETURN(0);
}
if (!(alias_str=thd->memdup(alias_str,table->table.length+1))) if (!(alias_str=thd->memdup(alias_str,table->table.length+1)))
DBUG_RETURN(0); DBUG_RETURN(0);
}
if (!(ptr = (TABLE_LIST *) thd->calloc(sizeof(TABLE_LIST)))) if (!(ptr = (TABLE_LIST *) thd->calloc(sizeof(TABLE_LIST))))
DBUG_RETURN(0); /* purecov: inspected */ DBUG_RETURN(0); /* purecov: inspected */
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment