Skip to content
Projects
Groups
Snippets
Help
Loading...
Help
Support
Keyboard shortcuts
?
Submit feedback
Contribute to GitLab
Sign in / Register
Toggle navigation
M
mariadb
Project overview
Project overview
Details
Activity
Releases
Repository
Repository
Files
Commits
Branches
Tags
Contributors
Graph
Compare
Issues
0
Issues
0
List
Boards
Labels
Milestones
Merge Requests
0
Merge Requests
0
Analytics
Analytics
Repository
Value Stream
Wiki
Wiki
Snippets
Snippets
Members
Members
Collapse sidebar
Close sidebar
Activity
Graph
Create a new issue
Commits
Issue Boards
Open sidebar
Kirill Smelkov
mariadb
Commits
8b427b7d
Commit
8b427b7d
authored
Apr 08, 2011
by
Vladislav Vaintroub
Browse files
Options
Browse Files
Download
Plain Diff
merge
parents
acc161d3
21199463
Changes
5
Show whitespace changes
Inline
Side-by-side
Showing
5 changed files
with
269 additions
and
32 deletions
+269
-32
sql/mysql_install_db.cc
sql/mysql_install_db.cc
+12
-12
win/packaging/CMakeLists.txt
win/packaging/CMakeLists.txt
+3
-0
win/packaging/ca/CustomAction.cpp
win/packaging/ca/CustomAction.cpp
+161
-9
win/packaging/ca/CustomAction.def
win/packaging/ca/CustomAction.def
+1
-0
win/packaging/extra.wxs.in
win/packaging/extra.wxs.in
+92
-11
No files found.
sql/mysql_install_db.cc
View file @
8b427b7d
...
...
@@ -322,7 +322,7 @@ static const char update_root_passwd_part2[]=
static
const
char
remove_default_user_cmd
[]
=
"DELETE FROM mysql.user where User='';
\n
"
;
static
const
char
allow_remote_root_access_cmd
[]
=
"CREATE TEMPORARY TABLE tmp_user LIKE user
engine=memory
;
\n
"
"CREATE TEMPORARY TABLE tmp_user LIKE user;
\n
"
"INSERT INTO tmp_user SELECT * from user where user='root' "
" AND host='localhost';
\n
"
"UPDATE tmp_user SET host='%';
\n
"
...
...
win/packaging/CMakeLists.txt
View file @
8b427b7d
...
...
@@ -99,6 +99,9 @@ GET_TARGET_PROPERTY(upgrade_wizard_location mysql_upgrade_wizard LOCATION)
IF
(
NOT upgrade_wizard_location
)
SET
(
EXTRA_WIX_PREPROCESSOR_FLAGS
"-dHaveUpgradeWizard=0"
)
ENDIF
()
IF
(
WITH_INNOBASE_STORAGE_ENGINE OR WITH_INNODB_STORAGE_ENGINE OR WITH_XTRADB_STORAGE_ENGINE
)
SET
(
EXTRA_WIX_PREPROCESSOR_FLAGS
${
EXTRA_WIX_PREPROCESSOR_FLAGS
}
"-dHaveInnodb=1"
)
ENDIF
()
IF
(
NOT CPACK_WIX_UI
)
SET
(
CPACK_WIX_UI
"MyWixUI_Mondo"
)
...
...
win/packaging/ca/CustomAction.cpp
View file @
8b427b7d
...
...
@@ -29,6 +29,7 @@ Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA */
#include <winservice.h>
#define ONE_MB 1048576
UINT
ExecRemoveDataDirectory
(
wchar_t
*
dir
)
{
/* Strip stray backslash */
...
...
@@ -436,16 +437,49 @@ LExit:
return
WcaFinalize
(
er
);
}
/*
Get maximum size of the buffer process can allocate.
this is calculated as min(RAM,virtualmemorylimit)
For 32bit processes, virtual address memory is 2GB (x86 OS)
or 4GB(x64 OS).
Fragmentation due to loaded modules, heap and stack
limit maximum size of continous memory block further,
so that limit for 32 bit process is about 1200 on 32 bit OS
or 2000 MB on 64 bit OS(found experimentally).
*/
unsigned
long
long
GetMaxBufferSize
(
unsigned
long
long
totalPhys
)
{
#ifdef _M_IX86
BOOL
wow64
;
if
(
IsWow64Process
(
GetCurrentProcess
(),
&
wow64
))
return
min
(
totalPhys
,
2000ULL
*
ONE_MB
);
else
return
min
(
totalPhys
,
1200ULL
*
ONE_MB
);
#else
return
totalPhys
;
#endif
}
/*
Checks SERVICENAME, PORT and BUFFERSIZE parameters
*/
extern
"C"
UINT
__stdcall
CheckDatabaseProperties
(
MSIHANDLE
hInstall
)
{
wchar_t
ServiceName
[
MAX_PATH
]
=
{
0
};
wchar_t
SkipNetworking
[
MAX_PATH
]
=
{
0
};
wchar_t
QuickConfig
[
MAX_PATH
]
=
{
0
};
wchar_t
Port
[
6
];
wchar_t
BufferPoolSize
[
16
];
DWORD
PortLen
=
6
;
bool
haveInvalidPort
=
false
;
const
wchar_t
*
ErrorMsg
=
0
;
HRESULT
hr
=
S_OK
;
UINT
er
=
ERROR_SUCCESS
;
hr
=
WcaInitialize
(
hInstall
,
__FUNCTION__
);
ExitOnFailure
(
hr
,
"Failed to initialize"
);
WcaLog
(
LOGMSG_STANDARD
,
"Initialized."
);
DWORD
ServiceNameLen
=
MAX_PATH
;
MsiGetPropertyW
(
hInstall
,
L"SERVICENAME"
,
ServiceName
,
&
ServiceNameLen
);
...
...
@@ -454,7 +488,7 @@ extern "C" UINT __stdcall CheckDatabaseProperties (MSIHANDLE hInstall)
if
(
ServiceNameLen
>
256
)
{
ErrorMsg
=
L"Invalid service name. The maximum length is 256 characters."
;
goto
err
;
goto
LExit
;
}
for
(
DWORD
i
=
0
;
i
<
ServiceNameLen
;
i
++
)
{
...
...
@@ -464,7 +498,7 @@ extern "C" UINT __stdcall CheckDatabaseProperties (MSIHANDLE hInstall)
ErrorMsg
=
L"Invalid service name. Forward slash and back slash are forbidden."
L"Single and double quotes are also not permitted."
;
goto
err
;
goto
LExit
;
}
}
if
(
CheckServiceExists
(
ServiceName
))
...
...
@@ -472,7 +506,7 @@ extern "C" UINT __stdcall CheckDatabaseProperties (MSIHANDLE hInstall)
ErrorMsg
=
L"A service with the same name already exists. "
L"Please use a different name."
;
goto
err
;
goto
LExit
;
}
}
...
...
@@ -508,7 +542,7 @@ extern "C" UINT __stdcall CheckDatabaseProperties (MSIHANDLE hInstall)
{
ErrorMsg
=
L"Invalid port number. Please use a number between 1025 and 65535."
;
goto
err
;
goto
LExit
;
}
short
port
=
(
short
)
_wtoi
(
Port
);
...
...
@@ -517,15 +551,133 @@ extern "C" UINT __stdcall CheckDatabaseProperties (MSIHANDLE hInstall)
ErrorMsg
=
L"The TCP Port you selected is already in use. "
L"Please choose a different port."
;
goto
err
;
goto
LExit
;
}
}
err:
DWORD
QuickConfigLen
=
MAX_PATH
;
MsiGetPropertyW
(
hInstall
,
L"STDCONFIG"
,
QuickConfig
,
&
QuickConfigLen
);
if
(
QuickConfig
[
0
]
!=
0
)
{
MEMORYSTATUSEX
memstatus
;
memstatus
.
dwLength
=
sizeof
(
memstatus
);
wchar_t
invalidValueMsg
[
256
];
if
(
!
GlobalMemoryStatusEx
(
&
memstatus
))
{
WcaLog
(
LOGMSG_STANDARD
,
"Error %u from GlobalMemoryStatusEx"
,
GetLastError
());
er
=
ERROR_INSTALL_FAILURE
;
goto
LExit
;
}
DWORD
BufferPoolSizeLen
=
16
;
MsiGetPropertyW
(
hInstall
,
L"BUFFERPOOLSIZE"
,
BufferPoolSize
,
&
BufferPoolSizeLen
);
/* Strip spaces */
for
(
DWORD
i
=
BufferPoolSizeLen
-
1
;
i
>
0
;
i
--
)
{
if
(
BufferPoolSize
[
i
]
==
' '
)
BufferPoolSize
[
i
]
=
0
;
}
unsigned
long
long
availableMemory
=
GetMaxBufferSize
(
memstatus
.
ullTotalPhys
)
/
ONE_MB
;
swprintf_s
(
invalidValueMsg
,
L"Invalid buffer pool size. Please use a number between 1 and %llu"
,
availableMemory
);
if
(
BufferPoolSizeLen
==
0
||
BufferPoolSizeLen
>
15
)
{
ErrorMsg
=
invalidValueMsg
;
goto
LExit
;
}
for
(
DWORD
i
=
0
;
i
<
BufferPoolSizeLen
&&
BufferPoolSize
[
BufferPoolSizeLen
];
i
++
)
{
if
(
BufferPoolSize
[
i
]
<
'0'
||
BufferPoolSize
[
i
]
>
'9'
)
{
ErrorMsg
=
invalidValueMsg
;
goto
LExit
;
}
}
BufferPoolSize
[
BufferPoolSizeLen
]
=
0
;
MsiSetPropertyW
(
hInstall
,
L"BUFFERPOOLSIZE"
,
BufferPoolSize
);
long
long
sz
=
_wtoi64
(
BufferPoolSize
);
if
(
sz
<=
0
||
sz
>
(
long
long
)
availableMemory
)
{
if
(
sz
>
0
)
{
swprintf_s
(
invalidValueMsg
,
L"Value for buffer pool size is too large."
L"Only approximately %llu MB is available for allocation."
L"Please use a number between 1 and %llu."
,
availableMemory
,
availableMemory
);
}
ErrorMsg
=
invalidValueMsg
;
goto
LExit
;
}
}
LExit:
MsiSetPropertyW
(
hInstall
,
L"WarningText"
,
ErrorMsg
);
return
ERROR_SUCCESS
;
return
WcaFinalize
(
er
)
;
}
/*
Sets Innodb buffer pool size (1/8 of RAM by default), if not already specified
via command line.
Calculates innodb log file size as min(50, innodb buffer pool size/8)
*/
extern
"C"
UINT
__stdcall
PresetDatabaseProperties
(
MSIHANDLE
hInstall
)
{
unsigned
long
long
InnodbBufferPoolSize
=
256
;
unsigned
long
long
InnodbLogFileSize
=
50
;
wchar_t
buff
[
MAX_PATH
];
UINT
er
=
ERROR_SUCCESS
;
HRESULT
hr
=
S_OK
;
MEMORYSTATUSEX
memstatus
;
hr
=
WcaInitialize
(
hInstall
,
__FUNCTION__
);
ExitOnFailure
(
hr
,
"Failed to initialize"
);
WcaLog
(
LOGMSG_STANDARD
,
"Initialized."
);
/* Check if bufferpoolsize parameter was given on the command line*/
DWORD
BufferPoolsizeParamLen
=
MAX_PATH
;
MsiGetPropertyW
(
hInstall
,
L"BUFFERPOOLSIZE"
,
buff
,
&
BufferPoolsizeParamLen
);
if
(
BufferPoolsizeParamLen
&&
buff
[
0
])
{
WcaLog
(
LOGMSG_STANDARD
,
"BUFFERPOOLSIZE=%s, len=%u"
,
buff
,
BufferPoolsizeParamLen
);
InnodbBufferPoolSize
=
_wtoi64
(
buff
);
}
else
{
memstatus
.
dwLength
=
sizeof
(
memstatus
);
if
(
!
GlobalMemoryStatusEx
(
&
memstatus
))
{
WcaLog
(
LOGMSG_STANDARD
,
"Error %u from GlobalMemoryStatusEx"
,
GetLastError
());
er
=
ERROR_INSTALL_FAILURE
;
goto
LExit
;
}
unsigned
long
long
totalPhys
=
memstatus
.
ullTotalPhys
;
/* Give innodb 12.5% of available physical memory. */
InnodbBufferPoolSize
=
totalPhys
/
ONE_MB
/
8
;
#ifdef _M_IX86
/*
For 32 bit processes, take virtual address space limitation into account.
Do not try to use more than 3/4 of virtual address space, even if there
is plenty of physical memory.
*/
InnodbBufferPoolSize
=
min
(
GetMaxBufferSize
(
totalPhys
)
/
ONE_MB
*
3
/
4
,
InnodbBufferPoolSize
);
#endif
swprintf_s
(
buff
,
L"%llu"
,
InnodbBufferPoolSize
);
MsiSetPropertyW
(
hInstall
,
L"BUFFERPOOLSIZE"
,
buff
);
}
InnodbLogFileSize
=
min
(
50
,
InnodbBufferPoolSize
);
swprintf_s
(
buff
,
L"%llu"
,
InnodbLogFileSize
);
MsiSetPropertyW
(
hInstall
,
L"LOGFILESIZE"
,
buff
);
LExit:
return
WcaFinalize
(
er
);
}
/* Remove service and data directory created by CreateDatabase operation */
extern
"C"
UINT
__stdcall
CreateDatabaseRollback
(
MSIHANDLE
hInstall
)
{
...
...
win/packaging/ca/CustomAction.def
View file @
8b427b7d
LIBRARY "wixca"
VERSION 1.0
EXPORTS
PresetDatabaseProperties
RemoveDataDirectory
CreateDatabaseRollback
CheckDatabaseProperties
...
...
win/packaging/extra.wxs.in
View file @
8b427b7d
<?xml version="1.0" encoding="utf-8"?>
<Wix
xmlns=
"http://schemas.microsoft.com/wix/2006/wi"
xmlns:util=
"http://schemas.microsoft.com/wix/UtilExtension"
>
<Fragment>
<Property
Id=
"PortTemplate"
Value=
"#####"
/>
<!--
Check, if upgrade wizard was built
It currently requires MFC, which is not in SDK
neither in express edítions of VS.
-->
<?ifndef HaveUpgradeWizard ?>
<?define HaveUpgradeWizard="1"?>
<?endif?>
<!-- If Innodb is compiled in, enable "optimize for transactions" checkbox -->
<?ifndef HaveInnodb ?>
<?define HaveInnodb="0"?>
<?endif?>
<Property
Id=
"PortTemplate"
Value=
"#####"
/>
<?if $(var.HaveInnodb) = "1" ?>
<Property
Id=
"BufferPoolSizeTemplate"
Value=
"#######"
/>
<?endif?>
<!--
Installation parameters that can be passed via msiexec command line
For "booleans" (like skip networking), just providing any value means property set to "yes".
...
...
@@ -30,14 +46,13 @@
<Property
Id=
"CLEANUPDATA"
Secure=
"yes"
Value=
"1"
/>
<!-- Force per machine installation -->
<Property
Id=
"ALLUSERS"
Secure=
"yes"
Value=
"1"
/>
<!--
Check, if upgrade wizard was built
It currently requires MFC, which is not in SDK
neither in express edítions of VS.
-->
<?ifndef HaveUpgradeWizard ?>
<?define HaveUpgradeWizard="1"?>
<?if $(var.HaveInnodb) = "1" ?>
<!-- Quick configuration : set default storage engine to innodb, use strict sql_mode -->
<Property
Id=
"STDCONFIG"
Secure=
"yes"
Value=
"1"
/>
<?endif?>
<!-- Innodb Buffer pool size in MB-->
<Property
Id=
"BUFFERPOOLSIZE"
Secure=
"yes"
/>
<!--
User interface dialogs
...
...
@@ -142,6 +157,8 @@
<!-- Error popup dialog -->
<Dialog
Id=
"WarningDlg"
Width=
"320"
Height=
"85"
Title=
"[ProductName] Setup"
NoMinimize=
"yes"
>
<Control
Id=
"Icon"
Type=
"Icon"
X=
"15"
Y=
"15"
Width=
"24"
Height=
"24"
ToolTip=
"Information icon"
FixedSize=
"yes"
IconSize=
"32"
Text=
"WixUI_Ico_Info"
/>
<Control
Id=
"Ok"
Type=
"PushButton"
X=
"132"
Y=
"57"
Width=
"56"
Height=
"17"
Default=
"yes"
Cancel=
"yes"
Text=
"OK"
>
<Publish
Property=
"WarningText"
>
1
</Publish>
...
...
@@ -261,6 +278,31 @@
<Condition
Action=
"enable"
>
EnableNetworking
</Condition>
<Condition
Action=
"disable"
>
Not EnableNetworking
</Condition>
</Control>
<?if $(var.HaveInnodb) = "1" ?>
<Control
Id=
"CheckBoxStandardConfig"
Type=
"CheckBox"
Height=
"18"
Width=
"220"
X=
"9"
Y=
"171"
Property=
"STDCONFIG"
CheckBoxValue=
"1"
>
<Text>
{\Font1}Optimize for transactions
</Text>
</Control>
<Control
Id=
"StandardConfigExplain"
Type=
"Text"
X=
"25"
Y=
"190"
Width=
"270"
Height=
"14"
TabSkip=
"yes"
>
<Text>
(Uses transactional storage engine and "strict" SQL mode)
</Text>
<Condition
Action=
"enable"
>
STDCONFIG
</Condition>
<Condition
Action=
"disable"
>
Not STDCONFIG
</Condition>
</Control>
<Control
Id=
"LabelInnodbBufferpool"
Type=
"Text"
Height=
"17"
Width=
"77"
X=
"25"
Y=
"210"
Text=
"Buffer pool size:"
>
<Condition
Action=
"enable"
>
STDCONFIG
</Condition>
<Condition
Action=
"disable"
>
Not STDCONFIG
</Condition>
</Control>
<Control
Id=
"BPSize"
Type=
"MaskedEdit"
X=
"104"
Y=
"208"
Width=
"40"
Height=
"15"
Property=
"BUFFERPOOLSIZE"
Sunken=
"yes"
Text=
"[BufferPoolSizeTemplate]"
>
<Condition
Action=
"enable"
>
STDCONFIG
</Condition>
<Condition
Action=
"disable"
>
Not STDCONFIG
</Condition>
</Control>
<Control
Id=
"LabelMB"
Type=
"Text"
Height=
"17"
Width=
"15"
X=
"150"
Y=
"210"
Text=
"MB"
>
<Condition
Action=
"enable"
>
STDCONFIG
</Condition>
<Condition
Action=
"disable"
>
Not STDCONFIG
</Condition>
</Control>
<?endif?>
<!-- Navigation buttons-->
<Control
Id=
"Back"
Type=
"PushButton"
X=
"180"
Y=
"243"
Width=
"56"
Height=
"17"
Text=
"&Back"
>
<Publish
Event=
"NewDialog"
Value=
"UserSettingsDlg"
>
1
</Publish>
...
...
@@ -379,7 +421,42 @@
<ServiceControl
Id=
'DBInstanceServiceStop'
Name=
'[SERVICENAME]'
Stop=
'both'
Remove=
'uninstall'
Wait=
'yes'
/>
<ServiceControl
Id=
'DBInstanceServiceStart'
Name=
'[SERVICENAME]'
Start=
'install'
Wait=
'yes'
/>
</Component>
<?if $(var.HaveInnodb) = "1" ?>
<Component
Id=
"C.myiniconfig"
Guid=
"*"
Directory=
"DATADIR"
>
<Condition>
STDCONFIG
</Condition>
<RegistryValue
Root=
'HKLM'
Key=
'SOFTWARE\@MANUFACTURER@\@CPACK_WIX_PACKAGE_NAME@'
Name=
'STDCONFIG'
Value=
'1'
Type=
'string'
KeyPath=
'yes'
/>
<IniFile
Id=
"Ini1"
Action=
"createLine"
Directory=
"DATADIR"
Section=
"mysqld"
Name=
"my.ini"
Key=
"sql_mode"
Value=
""STRICT_TRANS_TABLES,NO_ENGINE_SUBSTITUTION""
/>
<IniFile
Id=
"Ini2"
Action=
"createLine"
Directory=
"DATADIR"
Section=
"mysqld"
Name=
"my.ini"
Key=
"default_storage_engine"
Value=
"innodb"
/>
<IniFile
Id=
"Ini3"
Action=
"createLine"
Directory=
"DATADIR"
Section=
"mysqld"
Name=
"my.ini"
Key=
"innodb_buffer_pool_size"
Value=
"[BUFFERPOOLSIZE]M"
/>
<IniFile
Id=
"Ini4"
Action=
"createLine"
Directory=
"DATADIR"
Section=
"mysqld"
Name=
"my.ini"
Key=
"innodb_log_file_size"
Value=
"[LOGFILESIZE]M"
/>
</Component>
<?endif?>
<!--- Grant service account permission to the database folder (Windows 7 and later) -->
<Component
Id=
"C.serviceaccount.permission"
Guid=
"*"
Directory=
'DATADIR'
Transitive=
'yes'
>
<Condition>
<![CDATA[SERVICENAME AND (VersionNT > 600)]]>
</Condition>
...
...
@@ -484,7 +561,8 @@
Name=
"Upgrade Wizard (@CPACK_WIX_PACKAGE_NAME@)"
Target=
"[INSTALLDIR]bin\mysql_upgrade_wizard.exe"
Directory=
"ShortcutFolder"
Description=
"Upgrades older instances of MariaDB/MySQL services to version @MAJOR_VERSION@.@MINOR_VERSION@"
/>
Description=
"Upgrades older instances of MariaDB/MySQL services to version @MAJOR_VERSION@.@MINOR_VERSION@"
Advertise=
"no"
/>
</Component>
<?endif?>
</Feature>
...
...
@@ -494,6 +572,7 @@
<SetProperty
Sequence=
'execute'
Before=
'CreateDatabaseCommand'
Id=
"ALLOWREMOTEROOTACCESS"
Value=
"--allow-remote-root-access"
>
ALLOWREMOTEROOTACCESS
</SetProperty>
<SetProperty
Sequence=
'execute'
Before=
'CreateDatabaseCommand'
Id=
"DEFAULTUSER"
Value=
"--default-user"
>
DEFAULTUSER
</SetProperty>
<CustomAction
Id=
'CheckDatabaseProperties'
BinaryKey=
'wixca.dll'
DllEntry=
'CheckDatabaseProperties'
/>
<CustomAction
Id=
'PresetDatabaseProperties'
BinaryKey=
'wixca.dll'
DllEntry=
'PresetDatabaseProperties'
/>
<CustomAction
Id=
"CreateDatabaseCommand"
Property=
"CreateDatabase"
Value=
""[#F.bin.mysql_install_db.exe]" "--service=[SERVICENAME]" --port=[PORT] "--password=[PASSWORD]" "--datadir=[DATADIR]\" [SKIPNETWORKING] [ALLOWREMOTEROOTACCESS] [DEFAULTUSER]"
...
...
@@ -576,9 +655,11 @@
BinaryKey=
"wixca.dll"
DllEntry=
"CheckDBInUse"
Execute=
"firstSequence"
/>
<InstallExecuteSequence>
<Custom
Action=
"CheckDBInUse"
Before=
"LaunchConditions"
>
Installed
</Custom>
<Custom
Action=
"PresetDatabaseProperties"
After=
"CheckDBInUse"
></Custom>
</InstallExecuteSequence>
<InstallUISequence>
<Custom
Action=
"CheckDBInUse"
Before=
"LaunchConditions"
>
Installed
</Custom>
<Custom
Action=
"PresetDatabaseProperties"
After=
"CheckDBInUse"
></Custom>
</InstallUISequence>
<!-- Store some properties persistently in registry, mainly for upgrades -->
...
...
Write
Preview
Markdown
is supported
0%
Try again
or
attach a new file
Attach a file
Cancel
You are about to add
0
people
to the discussion. Proceed with caution.
Finish editing this message first!
Cancel
Please
register
or
sign in
to comment