Bug#27586: Wrong autoinc value assigned by LOAD DATA in the
NO_AUTO_VALUE_ON_ZERO mode. The table->auto_increment_field_not_null variable wasn't reset after reading a row which may lead to inserting a wrong value to the auto-increment field to the following row. The table->auto_increment_field_not_null variable is reset now right after a row is being written in the read_fixed_length() and the read_sep_field() functions. Removed wrong setting of the table->auto_increment_field_not_null variable in the read_sep_field() function.