Szymon Janc authored
It appears that some Broadcom controllers (eg BCM20702A0) reject LE Set Advertising Parameters command if advertising intervals provided are not within range for undirected and low duty directed advertising. Workaround this bug by populating min and max intervals with 'valid' values. < HCI Command: LE Set Advertising Parameters (0x08|0x0006) plen 15 Min advertising interval: 0.000 msec (0x0000) Max advertising interval: 0.000 msec (0x0000) Type: Connectable directed - ADV_DIRECT_IND (high duty cycle) (0x01) Own address type: Public (0x00) Direct address type: Random (0x01) Direct address: E2:F0:7B:9F:DC:F4 (Static) Channel map: 37, 38, 39 (0x07) Filter policy: Allow Scan Request from Any, Allow Connect Request from Any (0x00) > HCI Event: Command Complete (0x0e) plen 4 LE Set Advertising Parameters (0x08|0x0006) ncmd 1 Status: Invalid HCI Command Parameters (0x12) Signed-off-by: Szymon Janc <szymon.janc@codecoup.pl> Tested-by: Sören Beye <linux@hypfer.de> Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
4c371bb9