Chen-Yu Tsai authored
The PLLs have a "lock" bit in their configuration registers which indicate if the PLL has locked on to the requested clock rate. We check this bit in the .set_rate op. The PLL cannot lock on if it's not running, which might be a false positive (warning). Set the CLK_SET_RATE_UNGATE flag for all PLLs so whenever clk_set_rate is called on them, they get enabled and the "lock" check is really checking the PLL. Fixes: c6e6c96d ("clk: sunxi-ng: Add A31/A31s clocks") Signed-off-by: Chen-Yu Tsai <wens@csie.org> Acked-by: Maxime Ripard <maxime.ripard@free-electrons.com> Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>