Commit 0c7f7a51 authored by Viresh Kumar's avatar Viresh Kumar Committed by Matthias Brugger

arm: dts: mediatek: Add missing cooling device properties for CPUs

The cooling device properties, like "#cooling-cells" and
"dynamic-power-coefficient", should either be present for all the CPUs
of a cluster or none. If these are present only for a subset of CPUs of
a cluster then things will start falling apart as soon as the CPUs are
brought online in a different order. For example, this will happen
because the operating system looks for such properties in the CPU node
it is trying to bring up, so that it can register a cooling device.

Add such missing properties.
Signed-off-by: default avatarViresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: default avatarMatthias Brugger <matthias.bgg@gmail.com>
parent ce397d21
......@@ -92,6 +92,7 @@ cpu1: cpu@1 {
<&apmixedsys CLK_APMIXED_MAINPLL>;
clock-names = "cpu", "intermediate";
operating-points-v2 = <&cpu_opp_table>;
#cooling-cells = <2>;
clock-frequency = <1300000000>;
};
......@@ -103,6 +104,7 @@ cpu2: cpu@2 {
<&apmixedsys CLK_APMIXED_MAINPLL>;
clock-names = "cpu", "intermediate";
operating-points-v2 = <&cpu_opp_table>;
#cooling-cells = <2>;
clock-frequency = <1300000000>;
};
......@@ -114,6 +116,7 @@ cpu3: cpu@3 {
<&apmixedsys CLK_APMIXED_MAINPLL>;
clock-names = "cpu", "intermediate";
operating-points-v2 = <&cpu_opp_table>;
#cooling-cells = <2>;
clock-frequency = <1300000000>;
};
};
......