Commit 0ff8d1b3 authored by Matt Reimer's avatar Matt Reimer Committed by Greg Kroah-Hartman

USB: pxa27x_udc: use four bits to store endpoint addresses

Endpoint addresses on pxa27x can be programmed as 1-15, but since
only three bits were being used to store the endpoint number it
was possible to overflow.
Signed-off-by: default avatarMatt Reimer <mreimer@sdgsystems.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@suse.de>
parent 92a6e6b3
......@@ -360,7 +360,7 @@ struct pxa_ep {
* Specific pxa endpoint data, needed for hardware initialization
*/
unsigned dir_in:1;
unsigned addr:3;
unsigned addr:4;
unsigned config:2;
unsigned interface:3;
unsigned alternate:3;
......