Commit 128f29a4 authored by Florian Fainelli's avatar Florian Fainelli Committed by Sasha Levin

net: phy: Correctly process PHY_HALTED in phy_stop_machine()

[ Upstream commit 7ad813f2 ]

Marc reported that he was not getting the PHY library adjust_link()
callback function to run when calling phy_stop() + phy_disconnect()
which does not indeed happen because we set the state machine to
PHY_HALTED but we don't get to run it to process this state past that
point.

Fix this with a synchronous call to phy_state_machine() in order to have
the state machine actually act on PHY_HALTED, set the PHY device's link
down, turn the network device's carrier off and finally call the
adjust_link() function.
Reported-by: default avatarMarc Gonzalez <marc_gonzalez@sigmadesigns.com>
Fixes: a390d1f3 ("phylib: convert state_queue work to delayed_work")
Signed-off-by: default avatarFlorian Fainelli <f.fainelli@gmail.com>
Signed-off-by: default avatarMarc Gonzalez <marc_gonzalez@sigmadesigns.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
Signed-off-by: default avatarSasha Levin <alexander.levin@verizon.com>
parent 34e5d770
......@@ -512,6 +512,9 @@ void phy_stop_machine(struct phy_device *phydev)
if (phydev->state > PHY_UP && phydev->state != PHY_HALTED)
phydev->state = PHY_UP;
mutex_unlock(&phydev->lock);
/* Now we can run the state machine synchronously */
phy_state_machine(&phydev->state_queue.work);
}
/**
......