tipc: resolve connection flow control compatibility problem
In commit 10724cc7 ("tipc: redesign connection-level flow control") we replaced the previous message based flow control with one based on 1k blocks. In order to ensure backwards compatibility the mechanism falls back to using message as base unit when it senses that the peer doesn't support the new algorithm. The default flow control window, i.e., how many units can be sent before the sender blocks and waits for an acknowledge (aka advertisement) is 512. This was tested against the previous version, which uses an acknowledge frequency of on ack per 256 received message, and found to work fine. However, we missed the fact that versions older than Linux 3.15 use an acknowledge frequency of 512, which is exactly the limit where a 4.6+ sender will stop and wait for acknowledge. This would also work fine if it weren't for the fact that if the first sent message on a 4.6+ server side is an empty SYNACK, this one is also is counted as a sent message, while it is not counted as a received message on a legacy 3.15-receiver. This leads to the sender always being one step ahead of the receiver, a scenario causing the sender to block after 512 sent messages, while the receiver only has registered 511 read messages. Hence, the legacy receiver is not trigged to send an acknowledge, with a permanently blocked sender as result. We solve this deadlock by simply allowing the sender to send one more message before it blocks, i.e., by a making minimal change to the condition used for determining connection congestion. Signed-off-by: Jon Maloy <jon.maloy@ericsson.com> Signed-off-by: David S. Miller <davem@davemloft.net>