Commit 81d4f7bf authored by Tomasz Figa's avatar Tomasz Figa Committed by Olof Johansson

clocksource: samsung_pwm_timer: Work around rounding errors in clockevents core

Due to rounding errors in clockevents core (in conversions between ticks
and nsecs), it might happen that the set_next_event callback gets called
with cycles = 0, causing the code to incorrectly program the PWM timer.

This patch modifies the callback to program the timer for 1 tick, if
received tick count value is 0.
Signed-off-by: default avatarTomasz Figa <t.figa@samsung.com>
Signed-off-by: default avatarKyungmin Park <kyungmin.park@samsung.com>
Reviewed-by: default avatarArnd Bergmann <arnd@arndb.de>
Acked-by: default avatarKukjin Kim <kgene.kim@samsung.com>
Signed-off-by: default avatarOlof Johansson <olof@lixom.net>
parent 6fe4dfd0
...@@ -176,6 +176,19 @@ static void samsung_time_start(unsigned int channel, bool periodic) ...@@ -176,6 +176,19 @@ static void samsung_time_start(unsigned int channel, bool periodic)
static int samsung_set_next_event(unsigned long cycles, static int samsung_set_next_event(unsigned long cycles,
struct clock_event_device *evt) struct clock_event_device *evt)
{ {
/*
* This check is needed to account for internal rounding
* errors inside clockevents core, which might result in
* passing cycles = 0, which in turn would not generate any
* timer interrupt and hang the system.
*
* Another solution would be to set up the clockevent device
* with min_delta = 2, but this would unnecessarily increase
* the minimum sleep period.
*/
if (!cycles)
cycles = 1;
samsung_time_setup(pwm.event_id, cycles); samsung_time_setup(pwm.event_id, cycles);
samsung_time_start(pwm.event_id, false); samsung_time_start(pwm.event_id, false);
......