[S390] clock sync mode flags
The clock sync mode flag CLOCK_SYNC_STP is not cleared when stp
is set offline. In this case the get_sync_clock() function returns
-EACCESS and the dasd driver will block all i/o until stp is enabled
again. In addition get_sync_clock can return -EACCESS if the clock is
not in sync instead of -EAGAIN.
Rework the stp/etr online handling to fix these problems.
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Showing