MIPS: Alchemy: Increase minimum timeout for 32kHz timer.
Since a clocksource change post 3.2-rc1, tasks on my DB1500 board hang after random amounts of time (from a few minutes to a few hours), regardless of load. Debugging showed that the compare-match register value is a few seconds lower than the current counter value. The minimum value of 8 was initialy determined by a trial-and-error approach. Currently it is sufficient for all Alchemys (without PCI apparently), independent of CPU clock; only the DB1500 and DB1550 boards experience these timer-related tasks hangs now. This patch increases the minimum timeout by 1 (to 9 counter ticks) which seems sufficient since the systems are still working perfectly fine after over 24 hours. Signed-off-by: Manuel Lauss <manuel.lauss@googlemail.com> Cc: linux-mips@linux-mips.org Patchwork: https://patchwork.linux-mips.org/patch/3214/Signed-off-by: Ralf Baechle <ralf@linux-mips.org>