scsi: ufs: set load before setting voltage in regulators
This sequence change is required to avoid dips in voltage during boot-up. Apparently, this dip is caused because in the original sequence, the regulators are initialized in lpm mode. And then when the load is set to high, and more current is drawn, than is allowed in lpm, the dip is seen. Link: https://lore.kernel.org/r/1581392451-28743-3-git-send-email-cang@codeaurora.orgReviewed-by: Hongwu Su <hongwus@codeaurora.org> Reviewed-by: Bean Huo <beanhuo@micron.com> Reviewed-by: Stanley Chu <stanley.chu@mediatek.com> Signed-off-by: Asutosh Das <asutoshd@codeaurora.org> Signed-off-by: Can Guo <cang@codeaurora.org> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Showing
Please register or sign in to comment