Commit a80c49db authored by Peter Zijlstra's avatar Peter Zijlstra Committed by Greg Kroah-Hartman

serial8250: Mark console as CON_ANYTIME

While trying to debug a cpu-hotplug issue I noticed printk() stopped
working once the cpu got marked offline, since the 8250 serial console
doesn't have any per-cpu resources the CON_ANYTIME bit is the safe and
documented way to make it work again.
Signed-off-by: default avatarPeter Zijlstra <a.p.zijlstra@chello.nl>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@suse.de>
parent e53beacd
......@@ -2872,7 +2872,7 @@ static struct console serial8250_console = {
.device = uart_console_device,
.setup = serial8250_console_setup,
.early_setup = serial8250_console_early_setup,
.flags = CON_PRINTBUFFER,
.flags = CON_PRINTBUFFER | CON_ANYTIME,
.index = -1,
.data = &serial8250_reg,
};
......