staging: comedi: cb_pcidas64: fix incorrect AI range code handling
The hardware range code values and list of valid ranges for the AI subdevice is incorrect for several supported boards. The hardware range code values for all boards except PCI-DAS4020/12 is determined by calling `ai_range_bits_6xxx()` based on the maximum voltage of the range and whether it is bipolar or unipolar, however it only returns the correct hardware range code for the PCI-DAS60xx boards. For PCI-DAS6402/16 (and /12) it returns the wrong code for the unipolar ranges. For PCI-DAS64/Mx/16 it returns the wrong code for all the ranges and the comedi range table is incorrect. Change `ai_range_bits_6xxx()` to use a look-up table pointed to by new member `ai_range_codes` of `struct pcidas64_board` to map the comedi range table indices to the hardware range codes. Use a new comedi range table for the PCI-DAS64/Mx/16 boards (and the commented out variants). Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Cc: <stable@vger.kernel.org> # 3.18.x Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>