power: supply: max17040: Config alert SOC low level threshold from FDT
For configuration of fuel gauge alert for a low level state of charge interrupt we add a function to config level threshold and a device tree binding property to set it in flatned device tree node. Now we can use "maxim,alert-low-soc-level" property with the values from 1% up to 32% to configure alert interrupt threshold. Signed-off-by:Matheus Castello <matheus@castello.eng.br> Reviewed-by:
Krzysztof Kozlowski <krzk@kernel.org> Signed-off-by:
Sebastian Reichel <sebastian.reichel@collabora.com>