Commit f618e38d authored by Jesse Barnes's avatar Jesse Barnes Committed by Daniel Vetter

drm/i915/vlv: move DPIO common reset de-assert into __vlv_set_power_well

We need to do this anytime we power gate the DPIO common well.
Signed-off-by: default avatarJesse Barnes <jbarnes@virtuousgeek.org>
Reviewed-by: default avatarVille Syrjälä <ville.syrjala@linux.intel.com>
Signed-off-by: default avatarDaniel Vetter <daniel.vetter@ffwll.ch>
parent f099a3c6
......@@ -1525,19 +1525,6 @@ static void intel_reset_dpio(struct drm_device *dev)
false);
__vlv_set_power_well(dev_priv, PUNIT_POWER_WELL_DPIO_CMN_BC,
true);
/*
* From VLV2A0_DP_eDP_DPIO_driver_vbios_notes_10.docx -
* 6. De-assert cmn_reset/side_reset. Same as VLV X0.
* a. GUnit 0x2110 bit[0] set to 1 (def 0)
* b. The other bits such as sfr settings / modesel may all
* be set to 0.
*
* This should only be done on init and resume from S3 with
* both PLLs disabled, or we risk losing DPIO and PLL
* synchronization.
*/
I915_WRITE(DPIO_CTL, I915_READ(DPIO_CTL) | DPIO_CMNRST);
}
}
......
......@@ -5715,15 +5715,22 @@ void __vlv_set_power_well(struct drm_i915_private *dev_priv,
u32 state;
u32 ctrl;
if (power_well_id == PUNIT_POWER_WELL_DPIO_CMN_BC && enable) {
if (power_well_id == PUNIT_POWER_WELL_DPIO_CMN_BC) {
if (enable) {
/*
* Enable the CRI clock source so we can get at the display
* and the reference clock for VGA hotplug / manual detection.
* Enable the CRI clock source so we can get at the
* display and the reference clock for VGA
* hotplug / manual detection.
*/
I915_WRITE(DPLL(PIPE_B), I915_READ(DPLL(PIPE_B)) |
DPLL_REFA_CLK_ENABLE_VLV |
DPLL_INTEGRATED_CRI_CLK_VLV);
udelay(1); /* >10ns for cmnreset, >0ns for sidereset */
} else {
/* Assert common reset */
I915_WRITE(DPIO_CTL, I915_READ(DPIO_CTL) &
~DPIO_CMNRST);
}
}
mask = PUNIT_PWRGT_MASK(power_well_id);
......@@ -5752,6 +5759,20 @@ void __vlv_set_power_well(struct drm_i915_private *dev_priv,
out:
mutex_unlock(&dev_priv->rps.hw_lock);
/*
* From VLV2A0_DP_eDP_DPIO_driver_vbios_notes_10.docx -
* 6. De-assert cmn_reset/side_reset. Same as VLV X0.
* a. GUnit 0x2110 bit[0] set to 1 (def 0)
* b. The other bits such as sfr settings / modesel may all
* be set to 0.
*
* This should only be done on init and resume from S3 with
* both PLLs disabled, or we risk losing DPIO and PLL
* synchronization.
*/
if (power_well_id == PUNIT_POWER_WELL_DPIO_CMN_BC && enable)
I915_WRITE(DPIO_CTL, I915_READ(DPIO_CTL) | DPIO_CMNRST);
}
static void vlv_set_power_well(struct drm_i915_private *dev_priv,
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment