Commit d6855af6 authored by Claes Sjofors's avatar Claes Sjofors

Modbus TCP, function code WriteSingleRegister added

parent a7b09b7c
......@@ -87,8 +87,6 @@ static pwr_tStatus IoCardRead (
pwr_sClass_Modbus_TCP_ServerModule *op;
pwr_sClass_Modbus_TCP_Server *server;
printf( "Module: Read method\n");
op = (pwr_sClass_Modbus_TCP_ServerModule *) cp->op;
local = (io_sServerModuleLocal *) cp->Local;
server = (pwr_sClass_Modbus_TCP_Server *) rp->op;
......@@ -124,8 +122,6 @@ static pwr_tStatus IoCardWrite (
pwr_sClass_Modbus_TCP_ServerModule *op;
pwr_sClass_Modbus_TCP_Server *server;
printf( "Module: Write method\n");
op = (pwr_sClass_Modbus_TCP_ServerModule *) cp->op;
local = (io_sServerModuleLocal *) cp->Local;
server = (pwr_sClass_Modbus_TCP_Server *) rp->op;
......
......@@ -303,6 +303,7 @@ pwr_tStatus mb_recv_data(io_sRackLocal *local,
case pwr_eModbus_FCEnum_WriteMultipleCoils:
case pwr_eModbus_FCEnum_WriteMultipleRegisters:
case pwr_eModbus_FCEnum_WriteSingleRegister:
// Nothing good to do here
break;
}
......@@ -513,6 +514,33 @@ pwr_tStatus mb_send_data(io_sRackLocal *local,
wrr.bc = local_card->output_size;
memcpy(wrr.reg, local_card->output_area, local_card->output_size);
sts = send(local->s, &wrr, ntohs(wrr.head.length) + 6, MSG_DONTWAIT);
if (sts < 0) {
sp->Status = MB__CONNDOWN;
close(local->s);
errh_Error( "Connection down to modbus slave, %s", rp->Name);
return IO__SUCCESS;
}
sp->TX_packets++;
local->expected_msgs++;
break;
}
case pwr_eModbus_FCEnum_WriteSingleRegister: {
write_single_req wrr;
mp->SendOp = FALSE;
local->trans_id++;
local_card->trans_id = local->trans_id;
wrr.head.trans_id = htons(local->trans_id);
wrr.head.proto_id = 0;
wrr.head.length = htons(sizeof(wrr) - 6);
wrr.head.unit_id = mp->UnitId;
wrr.fc = mp->FunctionCode;
wrr.addr = htons(mp->Address);
memcpy(&wrr.value, local_card->output_area, sizeof(wrr.value));
sts = send(local->s, &wrr, ntohs(wrr.head.length) + 6, MSG_DONTWAIT);
if (sts < 0) {
sp->Status = MB__CONNDOWN;
......
......@@ -637,7 +637,6 @@ Volume OtherIO $ClassVolume 0.0.250.10
Object Port $Attribute 19 04-DEC-2009 17:22:45.73
Body SysBody 04-DEC-2009 17:23:01.72
Attr PgmName = "Port"
Attr Flags = 16777216
Attr TypeRef = "pwrs:Type-$UInt32"
EndBody
EndObject
......@@ -1104,9 +1103,9 @@ Volume OtherIO $ClassVolume 0.0.250.10
!
! The defines a Modbus/TCP server, i.e. makes it possible to act as a slave
! in the communication with a Modbus/TCP master.
!
!
! The Server object is placed in the node hierarchy under the node object.
!
!
! @classlink Modbus_TCP_ServerModule otherio_modbus_tcp_servermodule.html
!*/
Object Modbus_TCP_Server $ClassDef 6 25-NOV-2009 10:32:40.64
......@@ -1120,27 +1119,27 @@ Volume OtherIO $ClassVolume 0.0.250.10
Attr StructName = "Modbus_TCP_Server"
Attr NextAix = "_X39"
EndBody
!/**
! Description of the object.
!*/
!/**
! Description of the object.
!*/
Object Description $Attribute 19 25-NOV-2009 10:30:31.66
Body SysBody 25-NOV-2009 10:30:31.66
Attr PgmName = "Description"
Attr TypeRef = "pwrs:Type-$String80"
EndBody
EndObject
!/**
! Datasheet URL.
!*/
!/**
! Datasheet URL.
!*/
Object DataSheet $Attribute 20 25-NOV-2009 10:30:31.66
Body SysBody 25-NOV-2009 10:30:31.66
Attr PgmName = "DataSheet"
Attr TypeRef = "pwrs:Type-$URL"
EndBody
EndObject
!/**
! Current status of the server.
!*/
!/**
! Current status of the server.
!*/
Object Status $Attribute 21 25-NOV-2009 10:30:31.66
Body SysBody 04-DEC-2009 17:14:06.15
Attr PgmName = "Status"
......@@ -1178,8 +1177,8 @@ Volume OtherIO $ClassVolume 0.0.250.10
! @Summary Optional port number.
! Optional port number.
! By default the server listens to the Modbus TCP port 502.
! If another port should be used for the communication, it can be
! specified here.
! If another port should be used for the communication, it can be
! specified here.
!*/
Object Port $Attribute 38 04-DEC-2009 16:56:46.71
Body SysBody 04-DEC-2009 16:56:55.46
......@@ -1189,7 +1188,7 @@ Volume OtherIO $ClassVolume 0.0.250.10
EndObject
!/**
! If Yes, the server is disabled.
!*/
!*/
Object DisableServer $Attribute 25 25-NOV-2009 10:33:08.29
Body SysBody 25-NOV-2009 10:33:10.93
Attr PgmName = "DisableServer"
......@@ -1297,7 +1296,9 @@ Volume OtherIO $ClassVolume 0.0.250.10
EndObject
EndObject
Object Template Modbus_TCP_Server 2149285888 01-JAN-1970 01:00:00.00
Body RtBody 01-JAN-1970 01:00:00.00
Body RtBody 03-MAR-2010 16:51:13.57
Attr Process = 1
Attr ErrorLimit = 50
EndBody
EndObject
EndObject
......@@ -1324,40 +1325,40 @@ Volume OtherIO $ClassVolume 0.0.250.10
Attr StructName = "Modbus_TCP_ServerModule"
Attr NextAix = "_X21"
EndBody
!/**
! Description of the object.
!*/
!/**
! Description of the object.
!*/
Object Description $Attribute 11 25-NOV-2009 11:05:23.49
Body SysBody 25-NOV-2009 11:05:23.49
Attr PgmName = "Description"
Attr TypeRef = "pwrs:Type-$String80"
EndBody
EndObject
!/**
! @Summary Address for reading registers.
! Address for reading with function code ReadHoldingRegisters.
!/**
! @Summary Address for reading registers.
! Address for reading with function code ReadHoldingRegisters.
! The value defines the starting address for the input channels
! of class ChanIi and ChanAi.
!
! Note that the address for ReadDiscreteInputs and ReadCoils are
! not affected by the ReadAddress.
!*/
!
! Note that the address for ReadDiscreteInputs and ReadCoils are
! not affected by the ReadAddress.
!*/
Object ReadAddress $Attribute 12 04-DEC-2009 16:53:13.17
Body SysBody 04-DEC-2009 16:53:32.47
Attr PgmName = "ReadAddress"
Attr TypeRef = "pwrs:Type-$UInt32"
EndBody
EndObject
!/**
! @Summary Address for writing registers.
! Address for reading with function code WriteMultipleRegisters and
!/**
! @Summary Address for writing registers.
! Address for reading with function code WriteMultipleRegisters and
! WriteSingleRegister.
! The value defines the starting address for the output channels
! of class ChanIo and ChanAo.
!
! Note that the address for WriteSingleCoil and WriteMultipleCoils
!
! Note that the address for WriteSingleCoil and WriteMultipleCoils
! are not affected by the WriteAddress.
!*/
!*/
Object WriteAddress $Attribute 13 04-DEC-2009 16:53:43.87
Body SysBody 04-DEC-2009 16:53:45.81
Attr PgmName = "WriteAddress"
......@@ -1367,9 +1368,9 @@ Volume OtherIO $ClassVolume 0.0.250.10
!/**
! @Summary Unit id.
! Identification of the modbus unit to communicate with. It is typically
! only used if communicating with a tpc gateway that is connected to a
! Modbus serial line with possibly several units. Usually this has no
! meaning and should be set to zero (0).
! only used if communicating with a tpc gateway that is connected to a
! Modbus serial line with possibly several units. Usually this has no
! meaning and should be set to zero (0).
!*/
Object UnitId $Attribute 14 25-NOV-2009 11:05:23.49
Body SysBody 25-NOV-2009 11:05:23.49
......@@ -1432,7 +1433,8 @@ Volume OtherIO $ClassVolume 0.0.250.10
EndObject
EndObject
Object Template Modbus_TCP_ServerModule 2149548032 01-JAN-1970 01:00:00.00
Body RtBody 01-JAN-1970 01:00:00.00
Body RtBody 03-MAR-2010 16:49:58.18
Attr Process = 1
EndBody
EndObject
EndObject
......