Commit 0a9e0f94 authored by Jonghwa Lee's avatar Jonghwa Lee Committed by Sebastian Reichel

power: supply: charger-manager: Correct usage of CHARGE_NOW/FULL

The POWER_SUPPLY_CHARGE_NOW/FULL property reflects battery's charges
in uAh unit, but charger-manager has been used it wrongly as a
status field.
Signed-off-by: default avatarJonghwa Lee <jonghwa3.lee@samsung.com>
Signed-off-by: default avatarKrzysztof Kozlowski <k.kozlowski@samsung.com>
Signed-off-by: default avatarJonathan Bakker <xc-racer2@live.ca>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent cdaeb151
......@@ -846,35 +846,13 @@ static int charger_get_property(struct power_supply *psy,
val->intval = 0;
break;
case POWER_SUPPLY_PROP_CHARGE_FULL:
if (is_full_charged(cm))
val->intval = 1;
else
val->intval = 0;
ret = 0;
break;
case POWER_SUPPLY_PROP_CHARGE_NOW:
if (is_charging(cm)) {
fuel_gauge = power_supply_get_by_name(
cm->desc->psy_fuel_gauge);
fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
if (!fuel_gauge) {
ret = -ENODEV;
break;
}
ret = power_supply_get_property(fuel_gauge,
POWER_SUPPLY_PROP_CHARGE_NOW,
val);
if (ret) {
val->intval = 1;
ret = 0;
} else {
/* If CHARGE_NOW is supplied, use it */
val->intval = (val->intval > 0) ?
val->intval : 1;
}
} else {
val->intval = 0;
}
ret = power_supply_get_property(fuel_gauge, psp, val);
break;
default:
return -EINVAL;
......@@ -893,9 +871,9 @@ static enum power_supply_property default_charger_props[] = {
POWER_SUPPLY_PROP_VOLTAGE_NOW,
POWER_SUPPLY_PROP_CAPACITY,
POWER_SUPPLY_PROP_ONLINE,
POWER_SUPPLY_PROP_CHARGE_FULL,
/*
* Optional properties are:
* POWER_SUPPLY_PROP_CHARGE_FULL,
* POWER_SUPPLY_PROP_CHARGE_NOW,
* POWER_SUPPLY_PROP_CURRENT_NOW,
* POWER_SUPPLY_PROP_TEMP,
......@@ -1584,6 +1562,12 @@ static int charger_manager_probe(struct platform_device *pdev)
desc->psy_fuel_gauge);
return -ENODEV;
}
if (!power_supply_get_property(fuel_gauge,
POWER_SUPPLY_PROP_CHARGE_FULL, &val)) {
properties[num_properties] =
POWER_SUPPLY_PROP_CHARGE_FULL;
num_properties++;
}
if (!power_supply_get_property(fuel_gauge,
POWER_SUPPLY_PROP_CHARGE_NOW, &val)) {
properties[num_properties] =
......
Markdown is supported