arm64: dts: exynos: Remove clock from Exynos850 pmu_system_controller
As described in the corresponding binding documentation for "samsung,exynos850-pmu", the "clocks" property should be used for specifying CLKOUT mux inputs. Therefore, the clock provided to exynos850 pmu_system_controller is incorrect and should be removed. Instead of making syscon regmap keep that clock running for PMU accesses, it should be made always running in the clock driver, because the kernel is not the only software accessing PMU registers on Exynos850 platform. Signed-off-by: Sam Protsenko <semen.protsenko@linaro.org> Link: https://lore.kernel.org/r/20230308233822.31180-8-semen.protsenko@linaro.orgSigned-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org> Link: https://lore.kernel.org/r/20230612180102.289745-1-krzysztof.kozlowski@linaro.orgSigned-off-by: Arnd Bergmann <arnd@arndb.de>