Commit 24bb45fd authored by Jens Axboe's avatar Jens Axboe

Merge tag 'nvme-5.10-2020-10-29' of git://git.infradead.org/nvme into block-5.10

Pull NVMe fixes from Christoph:

"nvme updates for 5.10:

 - improve zone revalidation (Keith Busch)
 - gracefully handle zero length messages in nvme-rdma (zhenwei pi)
 - nvme-fc error handling fixes (James Smart)
 - nvmet tracing NULL pointer dereference fix (Chaitanya Kulkarni)"

* tag 'nvme-5.10-2020-10-29' of git://git.infradead.org/nvme:
  nvmet: fix a NULL pointer dereference when tracing the flush command
  nvme-fc: remove nvme_fc_terminate_io()
  nvme-fc: eliminate terminate_io use by nvme_fc_error_recovery
  nvme-fc: remove err_work work item
  nvme-fc: track error_recovery while connecting
  nvme-rdma: handle unexpected nvme completion data length
  nvme: ignore zone validate errors on subsequent scans
parents 7cb6e22b 3c3751f2
......@@ -2125,7 +2125,7 @@ static int nvme_update_ns_info(struct nvme_ns *ns, struct nvme_id_ns *id)
if (blk_queue_is_zoned(ns->queue)) {
ret = nvme_revalidate_zones(ns);
if (ret)
if (ret && !nvme_first_scan(ns->disk))
return ret;
}
......
......@@ -146,7 +146,8 @@ struct nvme_fc_rport {
/* fc_ctrl flags values - specified as bit positions */
#define ASSOC_ACTIVE 0
#define FCCTRL_TERMIO 1
#define ASSOC_FAILED 1
#define FCCTRL_TERMIO 2
struct nvme_fc_ctrl {
spinlock_t lock;
......@@ -157,7 +158,6 @@ struct nvme_fc_ctrl {
u32 cnum;
bool ioq_live;
atomic_t err_work_active;
u64 association_id;
struct nvmefc_ls_rcv_op *rcv_disconn;
......@@ -167,7 +167,6 @@ struct nvme_fc_ctrl {
struct blk_mq_tag_set tag_set;
struct delayed_work connect_work;
struct work_struct err_work;
struct kref ref;
unsigned long flags;
......@@ -2414,24 +2413,97 @@ nvme_fc_nvme_ctrl_freed(struct nvme_ctrl *nctrl)
nvme_fc_ctrl_put(ctrl);
}
/*
* This routine is used by the transport when it needs to find active
* io on a queue that is to be terminated. The transport uses
* blk_mq_tagset_busy_itr() to find the busy requests, which then invoke
* this routine to kill them on a 1 by 1 basis.
*
* As FC allocates FC exchange for each io, the transport must contact
* the LLDD to terminate the exchange, thus releasing the FC exchange.
* After terminating the exchange the LLDD will call the transport's
* normal io done path for the request, but it will have an aborted
* status. The done path will return the io request back to the block
* layer with an error status.
*/
static bool
nvme_fc_terminate_exchange(struct request *req, void *data, bool reserved)
{
struct nvme_ctrl *nctrl = data;
struct nvme_fc_ctrl *ctrl = to_fc_ctrl(nctrl);
struct nvme_fc_fcp_op *op = blk_mq_rq_to_pdu(req);
__nvme_fc_abort_op(ctrl, op);
return true;
}
/*
* This routine runs through all outstanding commands on the association
* and aborts them. This routine is typically be called by the
* delete_association routine. It is also called due to an error during
* reconnect. In that scenario, it is most likely a command that initializes
* the controller, including fabric Connect commands on io queues, that
* may have timed out or failed thus the io must be killed for the connect
* thread to see the error.
*/
static void
nvme_fc_error_recovery(struct nvme_fc_ctrl *ctrl, char *errmsg)
__nvme_fc_abort_outstanding_ios(struct nvme_fc_ctrl *ctrl, bool start_queues)
{
int active;
/*
* If io queues are present, stop them and terminate all outstanding
* ios on them. As FC allocates FC exchange for each io, the
* transport must contact the LLDD to terminate the exchange,
* thus releasing the FC exchange. We use blk_mq_tagset_busy_itr()
* to tell us what io's are busy and invoke a transport routine
* to kill them with the LLDD. After terminating the exchange
* the LLDD will call the transport's normal io done path, but it
* will have an aborted status. The done path will return the
* io requests back to the block layer as part of normal completions
* (but with error status).
*/
if (ctrl->ctrl.queue_count > 1) {
nvme_stop_queues(&ctrl->ctrl);
blk_mq_tagset_busy_iter(&ctrl->tag_set,
nvme_fc_terminate_exchange, &ctrl->ctrl);
blk_mq_tagset_wait_completed_request(&ctrl->tag_set);
if (start_queues)
nvme_start_queues(&ctrl->ctrl);
}
/*
* Other transports, which don't have link-level contexts bound
* to sqe's, would try to gracefully shutdown the controller by
* writing the registers for shutdown and polling (call
* nvme_shutdown_ctrl()). Given a bunch of i/o was potentially
* just aborted and we will wait on those contexts, and given
* there was no indication of how live the controlelr is on the
* link, don't send more io to create more contexts for the
* shutdown. Let the controller fail via keepalive failure if
* its still present.
*/
/*
* if an error (io timeout, etc) while (re)connecting,
* it's an error on creating the new association.
* Start the error recovery thread if it hasn't already
* been started. It is expected there could be multiple
* ios hitting this path before things are cleaned up.
* clean up the admin queue. Same thing as above.
*/
blk_mq_quiesce_queue(ctrl->ctrl.admin_q);
blk_mq_tagset_busy_iter(&ctrl->admin_tag_set,
nvme_fc_terminate_exchange, &ctrl->ctrl);
blk_mq_tagset_wait_completed_request(&ctrl->admin_tag_set);
}
static void
nvme_fc_error_recovery(struct nvme_fc_ctrl *ctrl, char *errmsg)
{
/*
* if an error (io timeout, etc) while (re)connecting, the remote
* port requested terminating of the association (disconnect_ls)
* or an error (timeout or abort) occurred on an io while creating
* the controller. Abort any ios on the association and let the
* create_association error path resolve things.
*/
if (ctrl->ctrl.state == NVME_CTRL_CONNECTING) {
active = atomic_xchg(&ctrl->err_work_active, 1);
if (!active && !queue_work(nvme_fc_wq, &ctrl->err_work)) {
atomic_set(&ctrl->err_work_active, 0);
WARN_ON(1);
}
__nvme_fc_abort_outstanding_ios(ctrl, true);
set_bit(ASSOC_FAILED, &ctrl->flags);
return;
}
......@@ -2745,30 +2817,6 @@ nvme_fc_complete_rq(struct request *rq)
nvme_fc_ctrl_put(ctrl);
}
/*
* This routine is used by the transport when it needs to find active
* io on a queue that is to be terminated. The transport uses
* blk_mq_tagset_busy_itr() to find the busy requests, which then invoke
* this routine to kill them on a 1 by 1 basis.
*
* As FC allocates FC exchange for each io, the transport must contact
* the LLDD to terminate the exchange, thus releasing the FC exchange.
* After terminating the exchange the LLDD will call the transport's
* normal io done path for the request, but it will have an aborted
* status. The done path will return the io request back to the block
* layer with an error status.
*/
static bool
nvme_fc_terminate_exchange(struct request *req, void *data, bool reserved)
{
struct nvme_ctrl *nctrl = data;
struct nvme_fc_ctrl *ctrl = to_fc_ctrl(nctrl);
struct nvme_fc_fcp_op *op = blk_mq_rq_to_pdu(req);
__nvme_fc_abort_op(ctrl, op);
return true;
}
static const struct blk_mq_ops nvme_fc_mq_ops = {
.queue_rq = nvme_fc_queue_rq,
......@@ -2988,6 +3036,8 @@ nvme_fc_create_association(struct nvme_fc_ctrl *ctrl)
ctrl->cnum, ctrl->lport->localport.port_name,
ctrl->rport->remoteport.port_name, ctrl->ctrl.opts->subsysnqn);
clear_bit(ASSOC_FAILED, &ctrl->flags);
/*
* Create the admin queue
*/
......@@ -3016,7 +3066,7 @@ nvme_fc_create_association(struct nvme_fc_ctrl *ctrl)
*/
ret = nvme_enable_ctrl(&ctrl->ctrl);
if (ret)
if (ret || test_bit(ASSOC_FAILED, &ctrl->flags))
goto out_disconnect_admin_queue;
ctrl->ctrl.max_segments = ctrl->lport->ops->max_sgl_segments;
......@@ -3026,7 +3076,7 @@ nvme_fc_create_association(struct nvme_fc_ctrl *ctrl)
blk_mq_unquiesce_queue(ctrl->ctrl.admin_q);
ret = nvme_init_identify(&ctrl->ctrl);
if (ret)
if (ret || test_bit(ASSOC_FAILED, &ctrl->flags))
goto out_disconnect_admin_queue;
/* sanity checks */
......@@ -3071,9 +3121,9 @@ nvme_fc_create_association(struct nvme_fc_ctrl *ctrl)
ret = nvme_fc_create_io_queues(ctrl);
else
ret = nvme_fc_recreate_io_queues(ctrl);
if (ret)
goto out_term_aen_ops;
}
if (ret || test_bit(ASSOC_FAILED, &ctrl->flags))
goto out_term_aen_ops;
changed = nvme_change_ctrl_state(&ctrl->ctrl, NVME_CTRL_LIVE);
......@@ -3107,60 +3157,6 @@ nvme_fc_create_association(struct nvme_fc_ctrl *ctrl)
}
/*
* This routine runs through all outstanding commands on the association
* and aborts them. This routine is typically be called by the
* delete_association routine. It is also called due to an error during
* reconnect. In that scenario, it is most likely a command that initializes
* the controller, including fabric Connect commands on io queues, that
* may have timed out or failed thus the io must be killed for the connect
* thread to see the error.
*/
static void
__nvme_fc_abort_outstanding_ios(struct nvme_fc_ctrl *ctrl, bool start_queues)
{
/*
* If io queues are present, stop them and terminate all outstanding
* ios on them. As FC allocates FC exchange for each io, the
* transport must contact the LLDD to terminate the exchange,
* thus releasing the FC exchange. We use blk_mq_tagset_busy_itr()
* to tell us what io's are busy and invoke a transport routine
* to kill them with the LLDD. After terminating the exchange
* the LLDD will call the transport's normal io done path, but it
* will have an aborted status. The done path will return the
* io requests back to the block layer as part of normal completions
* (but with error status).
*/
if (ctrl->ctrl.queue_count > 1) {
nvme_stop_queues(&ctrl->ctrl);
blk_mq_tagset_busy_iter(&ctrl->tag_set,
nvme_fc_terminate_exchange, &ctrl->ctrl);
blk_mq_tagset_wait_completed_request(&ctrl->tag_set);
if (start_queues)
nvme_start_queues(&ctrl->ctrl);
}
/*
* Other transports, which don't have link-level contexts bound
* to sqe's, would try to gracefully shutdown the controller by
* writing the registers for shutdown and polling (call
* nvme_shutdown_ctrl()). Given a bunch of i/o was potentially
* just aborted and we will wait on those contexts, and given
* there was no indication of how live the controlelr is on the
* link, don't send more io to create more contexts for the
* shutdown. Let the controller fail via keepalive failure if
* its still present.
*/
/*
* clean up the admin queue. Same thing as above.
*/
blk_mq_quiesce_queue(ctrl->ctrl.admin_q);
blk_mq_tagset_busy_iter(&ctrl->admin_tag_set,
nvme_fc_terminate_exchange, &ctrl->ctrl);
blk_mq_tagset_wait_completed_request(&ctrl->admin_tag_set);
}
/*
* This routine stops operation of the controller on the host side.
* On the host os stack side: Admin and IO queues are stopped,
......@@ -3237,7 +3233,6 @@ nvme_fc_delete_ctrl(struct nvme_ctrl *nctrl)
{
struct nvme_fc_ctrl *ctrl = to_fc_ctrl(nctrl);
cancel_work_sync(&ctrl->err_work);
cancel_delayed_work_sync(&ctrl->connect_work);
/*
* kill the association on the link side. this will block
......@@ -3292,78 +3287,34 @@ nvme_fc_reconnect_or_delete(struct nvme_fc_ctrl *ctrl, int status)
}
static void
__nvme_fc_terminate_io(struct nvme_fc_ctrl *ctrl)
nvme_fc_reset_ctrl_work(struct work_struct *work)
{
/*
* if state is CONNECTING - the error occurred as part of a
* reconnect attempt. Abort any ios on the association and
* let the create_association error paths resolve things.
*/
if (ctrl->ctrl.state == NVME_CTRL_CONNECTING) {
__nvme_fc_abort_outstanding_ios(ctrl, true);
return;
}
/*
* For any other state, kill the association. As this routine
* is a common io abort routine for resetting and such, after
* the association is terminated, ensure that the state is set
* to CONNECTING.
*/
struct nvme_fc_ctrl *ctrl =
container_of(work, struct nvme_fc_ctrl, ctrl.reset_work);
nvme_stop_keep_alive(&ctrl->ctrl);
nvme_stop_ctrl(&ctrl->ctrl);
/* will block will waiting for io to terminate */
nvme_fc_delete_association(ctrl);
if (ctrl->ctrl.state != NVME_CTRL_CONNECTING &&
!nvme_change_ctrl_state(&ctrl->ctrl, NVME_CTRL_CONNECTING))
if (!nvme_change_ctrl_state(&ctrl->ctrl, NVME_CTRL_CONNECTING))
dev_err(ctrl->ctrl.device,
"NVME-FC{%d}: error_recovery: Couldn't change state "
"to CONNECTING\n", ctrl->cnum);
}
static void
nvme_fc_reset_ctrl_work(struct work_struct *work)
{
struct nvme_fc_ctrl *ctrl =
container_of(work, struct nvme_fc_ctrl, ctrl.reset_work);
int ret;
__nvme_fc_terminate_io(ctrl);
nvme_stop_ctrl(&ctrl->ctrl);
if (ctrl->rport->remoteport.port_state == FC_OBJSTATE_ONLINE)
ret = nvme_fc_create_association(ctrl);
else
ret = -ENOTCONN;
if (ret)
nvme_fc_reconnect_or_delete(ctrl, ret);
else
dev_info(ctrl->ctrl.device,
"NVME-FC{%d}: controller reset complete\n",
ctrl->cnum);
if (ctrl->rport->remoteport.port_state == FC_OBJSTATE_ONLINE) {
if (!queue_delayed_work(nvme_wq, &ctrl->connect_work, 0)) {
dev_err(ctrl->ctrl.device,
"NVME-FC{%d}: failed to schedule connect "
"after reset\n", ctrl->cnum);
} else {
flush_delayed_work(&ctrl->connect_work);
}
} else {
nvme_fc_reconnect_or_delete(ctrl, -ENOTCONN);
}
}
static void
nvme_fc_connect_err_work(struct work_struct *work)
{
struct nvme_fc_ctrl *ctrl =
container_of(work, struct nvme_fc_ctrl, err_work);
__nvme_fc_terminate_io(ctrl);
atomic_set(&ctrl->err_work_active, 0);
/*
* Rescheduling the connection after recovering
* from the io error is left to the reconnect work
* item, which is what should have stalled waiting on
* the io that had the error that scheduled this work.
*/
}
static const struct nvme_ctrl_ops nvme_fc_ctrl_ops = {
.name = "fc",
......@@ -3491,7 +3442,6 @@ nvme_fc_init_ctrl(struct device *dev, struct nvmf_ctrl_options *opts,
ctrl->dev = lport->dev;
ctrl->cnum = idx;
ctrl->ioq_live = false;
atomic_set(&ctrl->err_work_active, 0);
init_waitqueue_head(&ctrl->ioabort_wait);
get_device(ctrl->dev);
......@@ -3499,7 +3449,6 @@ nvme_fc_init_ctrl(struct device *dev, struct nvmf_ctrl_options *opts,
INIT_WORK(&ctrl->ctrl.reset_work, nvme_fc_reset_ctrl_work);
INIT_DELAYED_WORK(&ctrl->connect_work, nvme_fc_connect_ctrl_work);
INIT_WORK(&ctrl->err_work, nvme_fc_connect_err_work);
spin_lock_init(&ctrl->lock);
/* io queue count */
......@@ -3592,7 +3541,6 @@ nvme_fc_init_ctrl(struct device *dev, struct nvmf_ctrl_options *opts,
fail_ctrl:
nvme_change_ctrl_state(&ctrl->ctrl, NVME_CTRL_DELETING);
cancel_work_sync(&ctrl->ctrl.reset_work);
cancel_work_sync(&ctrl->err_work);
cancel_delayed_work_sync(&ctrl->connect_work);
ctrl->ctrl.opts = NULL;
......
......@@ -1768,6 +1768,14 @@ static void nvme_rdma_recv_done(struct ib_cq *cq, struct ib_wc *wc)
return;
}
/* sanity checking for received data length */
if (unlikely(wc->byte_len < len)) {
dev_err(queue->ctrl->ctrl.device,
"Unexpected nvme completion length(%d)\n", wc->byte_len);
nvme_rdma_error_recovery(queue->ctrl);
return;
}
ib_dma_sync_single_for_cpu(ibdev, qe->dma, len, DMA_FROM_DEVICE);
/*
* AEN requests are special as they don't time out and can
......
......@@ -907,8 +907,6 @@ bool nvmet_req_init(struct nvmet_req *req, struct nvmet_cq *cq,
req->error_loc = NVMET_NO_ERROR_LOC;
req->error_slba = 0;
trace_nvmet_req_init(req, req->cmd);
/* no support for fused commands yet */
if (unlikely(flags & (NVME_CMD_FUSE_FIRST | NVME_CMD_FUSE_SECOND))) {
req->error_loc = offsetof(struct nvme_common_command, flags);
......@@ -938,6 +936,8 @@ bool nvmet_req_init(struct nvmet_req *req, struct nvmet_cq *cq,
if (status)
goto fail;
trace_nvmet_req_init(req, req->cmd);
if (unlikely(!percpu_ref_tryget_live(&sq->ref))) {
status = NVME_SC_INVALID_FIELD | NVME_SC_DNR;
goto fail;
......
......@@ -46,19 +46,12 @@ static inline struct nvmet_ctrl *nvmet_req_to_ctrl(struct nvmet_req *req)
return req->sq->ctrl;
}
static inline void __assign_disk_name(char *name, struct nvmet_req *req,
bool init)
static inline void __assign_req_name(char *name, struct nvmet_req *req)
{
struct nvmet_ctrl *ctrl = nvmet_req_to_ctrl(req);
struct nvmet_ns *ns;
if ((init && req->sq->qid) || (!init && req->cq->qid)) {
ns = nvmet_find_namespace(ctrl, req->cmd->rw.nsid);
strncpy(name, ns->device_path, DISK_NAME_LEN);
return;
}
memset(name, 0, DISK_NAME_LEN);
if (req->ns)
strncpy(name, req->ns->device_path, DISK_NAME_LEN);
else
memset(name, 0, DISK_NAME_LEN);
}
#endif
......@@ -81,7 +74,7 @@ TRACE_EVENT(nvmet_req_init,
TP_fast_assign(
__entry->cmd = cmd;
__entry->ctrl = nvmet_req_to_ctrl(req);
__assign_disk_name(__entry->disk, req, true);
__assign_req_name(__entry->disk, req);
__entry->qid = req->sq->qid;
__entry->cid = cmd->common.command_id;
__entry->opcode = cmd->common.opcode;
......@@ -121,7 +114,7 @@ TRACE_EVENT(nvmet_req_complete,
__entry->cid = req->cqe->command_id;
__entry->result = le64_to_cpu(req->cqe->result.u64);
__entry->status = le16_to_cpu(req->cqe->status) >> 1;
__assign_disk_name(__entry->disk, req, false);
__assign_req_name(__entry->disk, req);
),
TP_printk("nvmet%s: %sqid=%d, cmdid=%u, res=%#llx, status=%#x",
__print_ctrl_name(__entry->ctrl),
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment