Commit 340ff321 authored by Jens Axboe's avatar Jens Axboe

elevator: remove redundant warnings on IO scheduler switch

We warn twice for switching to a scheduler, if that switch fails.
As we also report the failure in the return value to the
sysfs write, remove the dmesg induced failures.

Keep the failure print for warning to switch to the kconfig
selected IO scheduler, as we can't report errors for that in
any other way.
Signed-off-by: default avatarJens Axboe <axboe@fb.com>
parent 43c1b3d6
......@@ -1062,10 +1062,8 @@ static int __elevator_change(struct request_queue *q, const char *name)
strlcpy(elevator_name, name, sizeof(elevator_name));
e = elevator_get(strstrip(elevator_name), true);
if (!e) {
printk(KERN_ERR "elevator: type %s not found\n", elevator_name);
if (!e)
return -EINVAL;
}
if (q->elevator &&
!strcmp(elevator_name, q->elevator->type->elevator_name)) {
......@@ -1105,7 +1103,6 @@ ssize_t elv_iosched_store(struct request_queue *q, const char *name,
if (!ret)
return count;
printk(KERN_ERR "elevator: switch to %s failed\n", name);
return ret;
}
......