at86rf230: change trac status check behaviour
When transmit is done, indicated by trx_end irq, we do first a force state change to TX_ON and then checking the trac status, if the trac status is unequal zero we do a state change to TRX_OFF. This patch changes to the following behaviour, we first check on trac status after trx_end occurs and then doing a normal change to TX_ON without do the state change to TRX_OFF when trac status is unequal zero. The reasons are that the datasheet doesn't described when the trac status register is cleared, we should doing to evaluate the trac status at first. The reason to remove the TRX_OFF change if the trac status is unequal to zero and it was force is the following paragraph inside The at86rf2xx datasheets: "Using FORCE_PLL_ON to interrupt an TX_ARET transaction, it is recommended to check register bits [7:5] of register address 0x32 for value 0. If this value is different, TRX_CMD sequence FORCE_TRX_OFF shall be used immediately followed by TRX_CMD sequence PLL_ON. This performs a state transition to PLL_ON." The meaning is here "to interrupt an TX_ARET transaction" in case of trx_end interrupt the "TX_ARET transaction" is already done and we don't interrupt the "TX_ARET transaction" by doing the change to TX_ON (PLL_ON) here. Additional I changed the force change to normal TX_ON which seems to work here. Signed-off-by: Alexander Aring <alex.aring@gmail.com> Reviewed-by: Stefan Schmidt <stefan@osg.samsung.com> Signed-off-by: Marcel Holtmann <marcel@holtmann.org>