Commit 36afb176 authored by Kweh, Hock Leong's avatar Kweh, Hock Leong Committed by Jonathan Cameron

iio: fix pressure data output unit in hid-sensor-attributes

According to IIO ABI definition, IIO_PRESSURE data output unit is
kilopascal:
http://lxr.free-electrons.com/source/Documentation/ABI/testing/sysfs-bus-iio

This patch fix output unit of HID pressure sensor IIO driver from pascal to
kilopascal to follow IIO ABI definition.
Signed-off-by: default avatarKweh, Hock Leong <hock.leong.kweh@intel.com>
Reviewed-by: default avatarSrinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: default avatarJonathan Cameron <jic23@kernel.org>
parent f8e81d7e
......@@ -56,8 +56,8 @@ static struct {
{HID_USAGE_SENSOR_ALS, 0, 1, 0},
{HID_USAGE_SENSOR_ALS, HID_USAGE_SENSOR_UNITS_LUX, 1, 0},
{HID_USAGE_SENSOR_PRESSURE, 0, 100000, 0},
{HID_USAGE_SENSOR_PRESSURE, HID_USAGE_SENSOR_UNITS_PASCAL, 1, 0},
{HID_USAGE_SENSOR_PRESSURE, 0, 100, 0},
{HID_USAGE_SENSOR_PRESSURE, HID_USAGE_SENSOR_UNITS_PASCAL, 0, 1000},
};
static int pow_10(unsigned power)
......