staging: iio: adc: ad7192: Use DT clock binding
This patch replaces the platform data clock select member with DT clock binding. Through the DT the external clock binding is specified. If this is not provided then the device will use the internal clock source. With the external clock binding there is the option to use a clock or a crystal as the clock source. When an external crystal is used it is connected to MCLK1 and MCLK2 pins. If the external clock is used only MCLK2 pin will be connected. Signed-off-by: Mircea Caprioru <mircea.caprioru@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>