gpio: sx150x: correct and refine reset-on-probe behavior
Replace the arbitrary software-reset call from the device-probe method, because: - It is defective. To work correctly, it should be two byte writes, not a single word write. As it stands, it does nothing. - Some devices with sx150x expanders installed have their NRESET pins ganged on the same line, so resetting one causes the others to reset - not a nice thing to do arbitrarily! - The probe, usually taking place at boot, implies a recent hard-reset, so a software reset at this point is just a waste of energy anyway. Therefore, make it optional, defaulting to off, as this will match the common case of probing at powerup and also matches the current broken no-op behavior. Signed-off-by: Gregory Bean <gbean@codeaurora.org> Reviewed-by: Jean Delvare <khali@linux-fr.org> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>