Commit 61541397 authored by Adrian Hunter's avatar Adrian Hunter Committed by Ulf Hansson

mmc: sdhci: Add quirk for always getting TC with stop cmd

Add a quirk for a host controller that always sets
a Transfer Complete interrupt status for the stop
command even when a busy response is not indicated.
Signed-off-by: default avatarAdrian Hunter <adrian.hunter@intel.com>
Signed-off-by: default avatarUlf Hansson <ulf.hansson@linaro.org>
parent 89168b48
...@@ -2225,7 +2225,7 @@ static void sdhci_tuning_timer(unsigned long data) ...@@ -2225,7 +2225,7 @@ static void sdhci_tuning_timer(unsigned long data)
* * * *
\*****************************************************************************/ \*****************************************************************************/
static void sdhci_cmd_irq(struct sdhci_host *host, u32 intmask) static void sdhci_cmd_irq(struct sdhci_host *host, u32 intmask, u32 *mask)
{ {
BUG_ON(intmask == 0); BUG_ON(intmask == 0);
...@@ -2272,6 +2272,9 @@ static void sdhci_cmd_irq(struct sdhci_host *host, u32 intmask) ...@@ -2272,6 +2272,9 @@ static void sdhci_cmd_irq(struct sdhci_host *host, u32 intmask)
/* The controller does not support the end-of-busy IRQ, /* The controller does not support the end-of-busy IRQ,
* fall through and take the SDHCI_INT_RESPONSE */ * fall through and take the SDHCI_INT_RESPONSE */
} else if ((host->quirks2 & SDHCI_QUIRK2_STOP_WITH_TC) &&
host->cmd->opcode == MMC_STOP_TRANSMISSION && !host->data) {
*mask &= ~SDHCI_INT_DATA_END;
} }
if (intmask & SDHCI_INT_RESPONSE) if (intmask & SDHCI_INT_RESPONSE)
...@@ -2481,7 +2484,8 @@ static irqreturn_t sdhci_irq(int irq, void *dev_id) ...@@ -2481,7 +2484,8 @@ static irqreturn_t sdhci_irq(int irq, void *dev_id)
} }
if (intmask & SDHCI_INT_CMD_MASK) if (intmask & SDHCI_INT_CMD_MASK)
sdhci_cmd_irq(host, intmask & SDHCI_INT_CMD_MASK); sdhci_cmd_irq(host, intmask & SDHCI_INT_CMD_MASK,
&intmask);
if (intmask & SDHCI_INT_DATA_MASK) if (intmask & SDHCI_INT_DATA_MASK)
sdhci_data_irq(host, intmask & SDHCI_INT_DATA_MASK); sdhci_data_irq(host, intmask & SDHCI_INT_DATA_MASK);
......
...@@ -98,6 +98,8 @@ struct sdhci_host { ...@@ -98,6 +98,8 @@ struct sdhci_host {
#define SDHCI_QUIRK2_BROKEN_HS200 (1<<6) #define SDHCI_QUIRK2_BROKEN_HS200 (1<<6)
/* Controller does not support DDR50 */ /* Controller does not support DDR50 */
#define SDHCI_QUIRK2_BROKEN_DDR50 (1<<7) #define SDHCI_QUIRK2_BROKEN_DDR50 (1<<7)
/* Stop command (CMD12) can set Transfer Complete when not using MMC_RSP_BUSY */
#define SDHCI_QUIRK2_STOP_WITH_TC (1<<8)
int irq; /* Device IRQ */ int irq; /* Device IRQ */
void __iomem *ioaddr; /* Mapped address */ void __iomem *ioaddr; /* Mapped address */
......