Commit 624ca9c3 authored by Ivan Mikhaylov's avatar Ivan Mikhaylov Committed by David S. Miller

net/ibm/emac: wrong bit is used for STA control register write

STA control register has areas of mode and opcodes for opeations. 18 bit is
using for mode selection, where 0 is old MIO/MDIO access method and 1 is
indirect access mode. 19-20 bits are using for setting up read/write
operation(STA opcodes). In current state 'read' is set into old MIO/MDIO mode
with 19 bit and write operation is set into 18 bit which is mode selection,
not a write operation. To correlate write with read we set it into 20 bit.
All those bit operations are MSB 0 based.
Signed-off-by: default avatarIvan Mikhaylov <ivan@de.ibm.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent 45d6e545
...@@ -244,7 +244,7 @@ struct emac_regs { ...@@ -244,7 +244,7 @@ struct emac_regs {
#define EMAC_STACR_PHYE 0x00004000 #define EMAC_STACR_PHYE 0x00004000
#define EMAC_STACR_STAC_MASK 0x00003000 #define EMAC_STACR_STAC_MASK 0x00003000
#define EMAC_STACR_STAC_READ 0x00001000 #define EMAC_STACR_STAC_READ 0x00001000
#define EMAC_STACR_STAC_WRITE 0x00002000 #define EMAC_STACR_STAC_WRITE 0x00000800
#define EMAC_STACR_OPBC_MASK 0x00000C00 #define EMAC_STACR_OPBC_MASK 0x00000C00
#define EMAC_STACR_OPBC_50 0x00000000 #define EMAC_STACR_OPBC_50 0x00000000
#define EMAC_STACR_OPBC_66 0x00000400 #define EMAC_STACR_OPBC_66 0x00000400
......