s390/nmi: fix order of register validation
When validating register contents first validate control registers since these control the availability of features later being validated. For example the control register 0 should be validated first, before the additional floating point (AFP) registers are validated, since control register 0 contains the AFP-register control bit. Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>