PM / shmobile: Remove the stay_on flag from SH7372's PM domains
SH7372 uses two independent mechanisms for ensuring that power domains will never be turned off: the stay_on flag and the "always on" domain governor. Moreover, the "always on" governor is only taken into accout by runtime PM code paths, while the stay_on flag affects all attempts to turn the given domain off. Thus setting the stay_on flag causes the "always on" governor to be unnecessary, which is quite confusing. However, the stay_on flag is currently only set for two domains: A3SP and A4S. Moreover, it only is set for the A3SP domain if console_suspend_enabled is set, so stay_on won't be necessary for that domain any more if console_suspend_enabled is checked directly in its .suspend() routine. [This requires domain .suspend() to return a result, but that is a minor modification.] Analogously, stay_on won't be necessary for the A4S domain if it's .suspend() routine always returns an error code. Signed-off-by: Rafael J. Wysocki <rjw@sisk.pl> Acked-by: Magnus Damm <damm@opensource.se>