Commit 77ad0f2e authored by Viresh Kumar's avatar Viresh Kumar Committed by Maxime Ripard

ARM: dts: sun8i-h3: Add missing cooling device properties for CPUs

The cooling device properties, like "#cooling-cells" and
"dynamic-power-coefficient", should either be present for all the CPUs
of a cluster or none. If these are present only for a subset of CPUs of
a cluster then things will start falling apart as soon as the CPUs are
brought online in a different order. For example, this will happen
because the operating system looks for such properties in the CPU node
it is trying to bring up, so that it can register a cooling device.

Add such missing properties.

Fix other missing properties (clocks, clock-names) as well to make it all
work.
Signed-off-by: default avatarViresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: default avatarMaxime Ripard <maxime.ripard@bootlin.com>
parent ce397d21
......@@ -84,21 +84,30 @@ cpu@1 {
compatible = "arm,cortex-a7";
device_type = "cpu";
reg = <1>;
clocks = <&ccu CLK_CPUX>;
clock-names = "cpu";
operating-points-v2 = <&cpu0_opp_table>;
#cooling-cells = <2>;
};
cpu@2 {
compatible = "arm,cortex-a7";
device_type = "cpu";
reg = <2>;
clocks = <&ccu CLK_CPUX>;
clock-names = "cpu";
operating-points-v2 = <&cpu0_opp_table>;
#cooling-cells = <2>;
};
cpu@3 {
compatible = "arm,cortex-a7";
device_type = "cpu";
reg = <3>;
clocks = <&ccu CLK_CPUX>;
clock-names = "cpu";
operating-points-v2 = <&cpu0_opp_table>;
#cooling-cells = <2>;
};
};
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment