Commit 850f94fe authored by Jaroslav Kysela's avatar Jaroslav Kysela

[ALSA] Fix interface type for some mixer controls

RME96 driver
The interface type of some basic mixer controls is changed from
IFACE_PCM to IFACE_MIXER so that it can be accessed from mixer apps.
Signed-off-by: default avatarPeter Chrisensen <peter@developers.dk>
Signed-off-by: default avatarTakashi Iwai <tiwai@suse.de>
parent 00c0c091
......@@ -2285,35 +2285,35 @@ static snd_kcontrol_new_t snd_rme96_controls[] = {
IEC958_AES0_PRO_EMPHASIS
},
{
.iface = SNDRV_CTL_ELEM_IFACE_PCM,
.iface = SNDRV_CTL_ELEM_IFACE_MIXER,
.name = "Input Connector",
.info = snd_rme96_info_inputtype_control,
.get = snd_rme96_get_inputtype_control,
.put = snd_rme96_put_inputtype_control
},
{
.iface = SNDRV_CTL_ELEM_IFACE_PCM,
.iface = SNDRV_CTL_ELEM_IFACE_MIXER,
.name = "Loopback Input",
.info = snd_rme96_info_loopback_control,
.get = snd_rme96_get_loopback_control,
.put = snd_rme96_put_loopback_control
},
{
.iface = SNDRV_CTL_ELEM_IFACE_PCM,
.iface = SNDRV_CTL_ELEM_IFACE_MIXER,
.name = "Sample Clock Source",
.info = snd_rme96_info_clockmode_control,
.get = snd_rme96_get_clockmode_control,
.put = snd_rme96_put_clockmode_control
},
{
.iface = SNDRV_CTL_ELEM_IFACE_PCM,
.iface = SNDRV_CTL_ELEM_IFACE_MIXER,
.name = "Monitor Tracks",
.info = snd_rme96_info_montracks_control,
.get = snd_rme96_get_montracks_control,
.put = snd_rme96_put_montracks_control
},
{
.iface = SNDRV_CTL_ELEM_IFACE_PCM,
.iface = SNDRV_CTL_ELEM_IFACE_MIXER,
.name = "Attenuation",
.info = snd_rme96_info_attenuation_control,
.get = snd_rme96_get_attenuation_control,
......