i2c: cadence: Check for errata condition involving master receive
Cadence I2C controller has the following bugs: - completion indication is not given to the driver at the end of a read/receive transfer with HOLD bit set. - Invalid read transaction are generated on the bus when HW timeout condition occurs with HOLD bit set. As a result of the above, if a set of messages to be transferred with repeated start includes any message following a read message, completion is never indicated and timeout occurs. Hence a check is implemented to return -EOPNOTSUPP for such sequences. Signed-off-by: Harini Katakam <harinik@xilinx.com> Signed-off-by: Vishnu Motghare <vishnum@xilinx.com> [wsa: fixed some whitespaces] Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
Showing
Please register or sign in to comment