Commit 8c3a7b0a authored by Stefan Brüns's avatar Stefan Brüns Committed by Greg Kroah-Hartman

iio: adc: ina2xx: Align timestamp with conversion ready flag

As the timestamp is no longer (ab-)used to measure the function run time,
it can be taken at the correct time, i.e. when the conversion has finished.
Signed-off-by: default avatarStefan Brüns <stefan.bruens@rwth-aachen.de>
Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 8ea2a638
...@@ -708,8 +708,6 @@ static int ina2xx_work_buffer(struct iio_dev *indio_dev) ...@@ -708,8 +708,6 @@ static int ina2xx_work_buffer(struct iio_dev *indio_dev)
s64 time; s64 time;
unsigned int alert; unsigned int alert;
time = iio_get_time_ns(indio_dev);
/* /*
* Because the timer thread and the chip conversion clock * Because the timer thread and the chip conversion clock
* are asynchronous, the period difference will eventually * are asynchronous, the period difference will eventually
...@@ -738,6 +736,8 @@ static int ina2xx_work_buffer(struct iio_dev *indio_dev) ...@@ -738,6 +736,8 @@ static int ina2xx_work_buffer(struct iio_dev *indio_dev)
} while (!alert); } while (!alert);
time = iio_get_time_ns(indio_dev);
/* /*
* Single register reads: bulk_read will not work with ina226/219 * Single register reads: bulk_read will not work with ina226/219
* as there is no auto-increment of the register pointer. * as there is no auto-increment of the register pointer.
......