Commit 90c0e5fc authored by Frederic Weisbecker's avatar Frederic Weisbecker

perf lock: Always check min AND max wait time

When a lock is acquired after beeing contended, we update the
wait time statistics for the given lock.
But if the min wait time is updated, we don't check the max wait
time. This is wrong because the first time we update the wait time,
we want to update both min and max wait time.

Before:
	Name   acquired  contended total wait (ns)   max wait (ns)   min wait (ns)
	key          8          1           21656           0           21656

After:
	Name   acquired  contended total wait (ns)   max wait (ns)   min wait (ns)
	key          8          1           21656           21656           21656
Signed-off-by: default avatarFrederic Weisbecker <fweisbec@gmail.com>
Cc: Ingo Molnar <mingo@elte.hu>
Cc: Peter Zijlstra <a.p.zijlstra@chello.nl>
Cc: Arnaldo Carvalho de Melo <acme@redhat.com>
Cc: Paul Mackerras <paulus@samba.org>
Cc: Hitoshi Mitake <mitake@dcl.info.waseda.ac.jp>
parent 5efe08cf
......@@ -496,7 +496,7 @@ report_lock_acquired_event(struct trace_acquired_event *acquired_event,
ls->wait_time_total += contended_term;
if (contended_term < ls->wait_time_min)
ls->wait_time_min = contended_term;
else if (ls->wait_time_max < contended_term)
if (ls->wait_time_max < contended_term)
ls->wait_time_max = contended_term;
break;
case SEQ_STATE_RELEASED:
......