Commit 92529df7 authored by Michael Chan's avatar Michael Chan Committed by David S. Miller

bnxt_en: Use register window 6 instead of 5 to read the PHC

Some older Broadcom debug tools use window 5 and may conflict, so switch
to use window 6 instead.

Fixes: 118612d5 ("bnxt_en: Add PTP clock APIs, ioctls, and ethtool methods")
Reviewed-by: default avatarAndy Gospodarek <gospo@broadcom.com>
Signed-off-by: default avatarMichael Chan <michael.chan@broadcom.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent 9e266807
......@@ -10,8 +10,8 @@
#ifndef BNXT_PTP_H
#define BNXT_PTP_H
#define BNXT_PTP_GRC_WIN 5
#define BNXT_PTP_GRC_WIN_BASE 0x5000
#define BNXT_PTP_GRC_WIN 6
#define BNXT_PTP_GRC_WIN_BASE 0x6000
#define BNXT_MAX_PHC_DRIFT 31000000
#define BNXT_LO_TIMER_MASK 0x0000ffffffffUL
......