pwm-backlight: Enable/disable the PWM before/after LCD enable toggle.
commit 5fb5caee upstream. Before this patch the enable signal was set before the PWM signal and vice-versa on power off. This sequence is wrong, at least, it is on the different panels datasheets that I checked, so I inverted the sequence to follow the specs. For reference the following panels have the mentioned sequence: - N133HSE-EA1 (Innolux) - N116BGE (Innolux) - N156BGE-L21 (Innolux) - B101EAN0 (Auo) - B101AW03 (Auo) - LTN101NT05 (Samsung) - CLAA101WA01A (Chunghwa) Signed-off-by:Enric Balletbo i Serra <enric.balletbo@collabora.com> Acked-by:
Daniel Thompson <daniel.thompson@linaro.org> Acked-by:
Jingoo Han <jingoohan1@gmail.com> Acked-by:
Thierry Reding <thierry.reding@gmail.com> Signed-off-by:
Lee Jones <lee.jones@linaro.org> Signed-off-by:
Arnd Bergmann <arnd@arndb.de> Signed-off-by:
Greg Kroah-Hartman <gregkh@linuxfoundation.org>