iio: adc: palmas: add support for iio threshold events
The palmas gpadc block has support for monitoring up to 2 ADC channels and issue an interrupt if they reach past a set threshold. This change hooks into the IIO events system and exposes to userspace the ability to configure these threshold values for each channel, but only allow up to 2 such thresholds to be enabled at any given time. Trying to enable a third channel will result in an error. Userspace is expected to input calibrated, as opposed to raw, values as threshold. However, it is not enough to do the opposite of what is done when converting the other way around. To account for tolerances in the ADC, the calculated raw threshold should be adjusted based on the ADC specifications for the device. These specifications include the integral nonlinearity (INL), offset, and gain error. To adjust the high threshold, use the following equation: (calibrated value + INL) * Gain error + offset = maximum value [1] Likewise, use the following equation for the low threshold: (calibrated value - INL) * Gain error - offset = minimum value The gain error is a combination of gain error, as listed in the datasheet, and gain error drift due to temperature and supply. The exact values for these specifications vary between palmas devices. This patch sets the values found in TWL6035, TWL6037 datasheet. [1] TI Application Report, SLIA087A, Guide to Using the GPADC in TPS65903x, TPS65917-Q1, TPS65919-Q1, and TPS65916 Devices. Signed-off-by: Patrik Dahlström <risca@dalakolonin.se> Link: https://lore.kernel.org/r/20230408114825.824505-9-risca@dalakolonin.seSigned-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>