net: phy: fix interrupt handling in non-started states
phylib enables interrupts before phy_start() has been called, and if we receive an interrupt in a non-started state, the interrupt handler returns IRQ_NONE. This causes problems with at least one Marvell chip as reported by Andrew. Fix this by handling interrupts the same as in phy_mac_interrupt(), basically always running the phylib state machine. It knows when it has to do something and when not. This change allows to handle interrupts gracefully even if they occur in a non-started state. Fixes: 2b3e88ea ("net: phy: improve phy state checking") Reported-by: Andrew Lunn <andrew@lunn.ch> Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Reviewed-by: Florian Fainelli <f.fainelli@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>