clocksource/drivers/lpc32: Correct pr_err() output format
If by some reason timerclk is not available, both clockevent and clocksource initializations correctly exit, but output of errno to kernel log buffer may be confusing: lpc32xx_clk_init: failed to map system control block registers lpc32xx_clocksource_init: clock get failed (4294966779) lpc32xx_clockevent_init: clock get failed (4294966779) Use signed integer output in the correspondent pr_err() string formats: lpc32xx_clocksource_init: clock get failed (-517) lpc32xx_clockevent_init: clock get failed (-517) Signed-off-by: Vladimir Zapolskiy <vz@mleia.com> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>