Commit f0297cc0 authored by Imre Deak's avatar Imre Deak

drm/dp_mst: Tune down the WARN modesetting a port with full_pbn=0

It's possible to modeset a connector/mst port that has a 0 full_pbn
value: if the sink on the port deasserts its HPD and a branch device
reports this via a CSN with the port's ddps=0 and pdt!=NONE the driver
clears full_pbn, but the corresponding connector can be still
modesetted.

This happened on a DELL U2719D monitor as the branch device and an LG
27UL650-W daisy-chained to it, the LG monitor generating a long HPD
pulse (doing this for some reason always when waking up from some power
saving state).

Tune down the WARN about this scenario to a debug message.

v2: Use the correct atomic debug message level. (Lyude)

References: https://gitlab.freedesktop.org/drm/intel/-/issues/1917
Cc: Lyude Paul <lyude@redhat.com>
Signed-off-by: default avatarImre Deak <imre.deak@intel.com>
Reviewed-by: default avatarLyude Paul <lyude@redhat.com>
Link: https://patchwork.freedesktop.org/patch/msgid/20210216123448.410545-1-imre.deak@intel.com
parent 1b588c82
......@@ -5105,11 +5105,16 @@ drm_dp_mst_atomic_check_port_bw_limit(struct drm_dp_mst_port *port,
if (!found)
return 0;
/* This should never happen, as it means we tried to
* set a mode before querying the full_pbn
/*
* This could happen if the sink deasserted its HPD line, but
* the branch device still reports it as attached (PDT != NONE).
*/
if (WARN_ON(!port->full_pbn))
if (!port->full_pbn) {
drm_dbg_atomic(port->mgr->dev,
"[MSTB:%p] [MST PORT:%p] no BW available for the port\n",
port->parent, port);
return -EINVAL;
}
pbn_used = vcpi->pbn;
} else {
......